Featured

  • China High Quality Circuit Breaker Test Equipment Factories –  GDSL-A Automatic 3-phase Primary Current Injection Test Set with Temperature Test – HV Hipot

    China High Quality Circuit Breaker Test Equipment Factories – GDSL-A Automatic 3-phase Primary Current Injection Test Set with Temperature Test – HV Hipot

    Features ● Built-in high configuration industrial control computer, the programmable logic controller (PLC) as the central processor, real-time scan of AC signal, to achieve comprehensive monitoring and closed-loop control, and design password settings management, only the personnel who gets corresponding operation authority, can carry out operation of certain functions. ● Color LCD touch screen. Using intelligent sensor based on field bus technology and realize the full digital data transmission, display operation unit is touch type color LCD screen, full English menu, the interface is clear and intuitive, the operation is simple and convenient. Test without any auxiliary equipment, automatic control, fast, simple and convenient. ● Automatic and manual test mode, with automatic constan...
  • China High Quality tester machine Exporters –  Battery Discharge Tester – HV Hipot

    China High Quality tester machine Exporters – Battery Discharge Tester – HV Hipot

    Product drawing of battery discharge load bank  Battery Discharge Tester / Battery Discharge Load Bank (Specification) Applicable battery DC 380V / DC 48V Output voltage DC 304-456V / DC 38-60V Output current 0-30A / 0-100A Working mode Can be used stand-alone, multi-machine parallel operation in constant current mode Protection function Input terminal over voltage protection, LCD indicate. Battery voltage polarity reverse protection, buzzer alarm. Over current protection, LCD indicate. 65°C overheat protection, LCD indicate, buzzer alarm; Single voltage acquisition Use 433 RF wireless module, communication distance up to 100 meters, compatible with 2V/4V/6V/12V single battery voltage monitoring, as long as the total voltage does not exceed the threshold, ...
  • OEM Best Ignition Coil Resistance Test Exporters –  GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot

    OEM Best Ignition Coil Resistance Test Exporters – GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot

    Adoption of Standard ● DL/T 596-2005 “Procedure Test Procedures for Electrical Equipment” ● GB1094.1-GB1094.6-96 “Shell protection level” ● GB2900 “Electrical Terminology” ● GB/T16927.1~2-1997 “High Voltage Test Technology” ● GB4793-1984 “Safety Requirements for Electronic Measuring Instruments” ● GB191 “Package Storage and Transportation Mark” ● GB/T.311-1997 “Insulation and coordination of high voltage power transmission and transformation equipment” Features ● Using high conductivity copper as the output electrode, the contact surface is large and the flow capacity is strong. ● Brushed aluminum plate with a new process, simple and eye-catching, wear-resistant and pollution-resistant. ● The all-...
  • China High Quality Power Cable Fault Location Suppliers –  GD-4138H Cable Fault Locating System – HV Hipot

    China High Quality Power Cable Fault Location Suppliers – GD-4138H Cable Fault Locating System – HV Hipot

    GD-4138H Mobile Cable Fault Locating System is important tool to maintain all kinds of cables. It is compatible equipment that can trace, locate the underground cables, with fault distance measurement and HV generation. As it is movable device, it is convenient to carry on-site. If acoustic locator is used together, it can locate accurate position of cable fault point. Application is underground cable, aerial cable, power cable, local cable, communication cable and fiber cable. Typical fault to be detected includes ● High impedance flash-over fault ● High impedance leak ● High/low resistive grounding ● Short-circuit fault ● Open-circuit fault ● Poor connection/Disconnection GD-4138L system includes ● GD-4138H main frame (Coupling device, Sphere gap, HV generator are inside) ● GD-...
  • OEM Best Capacitance Tester Manufacturer –  Insulation Materials Hipot Test Set GDJS-65 – HV Hipot

    OEM Best Capacitance Tester Manufacturer – Insulation Materials Hipot Test Set GDJS-65 – HV Hipot

    GDJS-65 Insulation Gloves Test Set It is used to test insulation performance for insulation gloves, boots, mats, hats, rod, Electroscope etc. It can test 6pcs insulation gloves/boots at the same time, also 5pcs insulation rods. Features Manual control unit ● Digital and real time display HV voltage, LV current, 6-way leak current and time. ● With leak current meter and over-current protection meter. ● With movable control unit, easy wiring and testing. ● Manual control, safety and reliability. ● With zero, power, operation, timing indicators. ● With over-current protection, zero-start protection, sound and light alarm, power protected switch. ● New type timer, broader timing range.(1s-99h). Other features ● HV source is oil immersed type testing transformer.(dry type and SF6 gas t...
  • OEM Best Sf6 Gas Density Relay Calibrator Factories –  GDWG-V SF6 Gas Leak Detector (IR type, Double display) – HV Hipot

    OEM Best Sf6 Gas Density Relay Calibrator Factories – GDWG-V SF6 Gas Leak Detector (IR type, Double display) – HV Hipot

    Product Description GDWG-V SF6 Gas Leak Detector is infrared red type leak detector (NDIR technology) with double display. It is color INCELL TFT display and real-time shows SF6 concentration. It rapidly detects SF6 breaker, GIS leakage point and yearly leakage rate qualitatively and quantitatively. It is a good device suitable for power supply department, installation and overhaul unit, power test institute. Application ● High Voltage Switch Equipment ● Rotor vane of helicopter ● Gas transmission system ● To detect fire extinguisher ● Ventilation efficiency research of Buildings ● To detect danger Advantages ● No radiation. ● No need to replace high pressure high pure argon gas regularly. ● No need to approach high pressure gas. ● No need to replace sensors regularl...
  • China High Quality Simulate Lightning Impulse Exporters –  GDOT-100D 100kV Insulation Oil Tester – HV Hipot

    China High Quality Simulate Lightning Impulse Exporters – GDOT-100D 100kV Insulation Oil Tester – HV Hipot

    General Information In power system, railway system and large petrochemical industrial enterprises all have  a lot of electrical equipment, its internal insulation is mostly oil-filled insulation type. Dielectric strength test for insulating oil is a routine test which shall be measured.  In order to meet the market needs. Our company self-developed and produced  GDOT series dielectric strength tester for insulation oil according to national standard  GB/T5072002, industrial standard DL429.991 and the latest electric power industry standard DL/T846.7- 2004.  The instrument use single chip microcomputer as the core, to achieve full automatic testing and high precision measurement, greatly improves the work efficiency and also reduce the labor intensity of the workers greatly. Featu...
  • OEM Best Capacitor Analyzer Manufacturer –  AC Dielectric Test Equipment with manual control unit GDYD-M – HV Hipot

    OEM Best Capacitor Analyzer Manufacturer – AC Dielectric Test Equipment with manual control unit GDYD-M – HV Hipot

    Application AC Hipot testing is the effective and direct way to test insulation strength for electric equipment, apparatus, or machines. It checks dangerous flaws which assure electric equipment continuous working. Typical applications include testing of transformers, switchgear, cables, capacitors, aerial motors platforms, hot sticks bucket bricks, vacuum bottles and other related equipment like vacuum interrupters, blankets, ropes, gloves, hydraulics hose, instruments transformers generators. Features ● Pointer display panel mounted controls & indicators with easy-to-read legend. ● Monitoring high voltage side voltage, low voltage side current and indicator of zero, power, working start, timing. ● Over-current protection, zero-starting protection, sound, and light alarm. ● C...
  • OEM Best High Voltage Instruments Factory –  GDCY Impulse Voltage Test System (100kV-7200kV) – HV Hipot

    OEM Best High Voltage Instruments Factory – GDCY Impulse Voltage Test System (100kV-7200kV) – HV Hipot

    Application This impulse test system is used for carrying out full wave lightning impulse voltage tests on HV apparatus such as clearance, bushings, capacitors, switches, power transformers(capacity below 5000kVA), CT/PT at 35kV or below. Operating Condition ● Altitude: 1000m. ● Ambient Temperature: -5℃~+45℃. ● Max. daily difference temperature: ≤25℃. ● Relative humidity: <90%. ● Anti-shock ability: ≤ level 7. ● Horizontal acceleration of the ground: 3.0m/s2, Vertical acceleration of the ground: 1.5m/s2. ● Waveform of power supply voltage wave is sine actually, and the waveform distortion rate<3%. ● It should be grounded reliably, ground resistance <0.5Ω. ● Usage environment: indoor. No conductive dust, No fire and explosion, No corrosive metal and insulation gas. Applied Sta...
  • OEM Best open cup flash point adalah Suppliers –  GDCP-510 Oil Freezing Point Tester – HV Hipot

    OEM Best open cup flash point adalah Suppliers – GDCP-510 Oil Freezing Point Tester – HV Hipot

    General Information  GDCP-510 Low Temperature Freezing Point Tester is compliant with GB/T 510 “Determination of Solidification Point for Petroleum Products” and GB/T 3535 ”Petroleum Products―Determination of Pour Point. “(ISO 3016) It adopts compressor refrigeration, enclosed bath, equipped with tilt bracket and automatic digital display controller, which uses fuzzy control and PID self-tuning technology, performance is more stable. Specification Temperature range Room temperature to -75ºC. Accuracy ±0.1ºC Refrigeration Germany imported sensor, cascade compressor refrigeration, with new type refrigerant, more quickly and environment friendly. Structure Two-slot & four-hole Temperature correction and display based on automati...
  • China High Quality Voltage Pulse Generator Factory –  GDZRC series DC Winding Resistance Tester – HV Hipot

    China High Quality Voltage Pulse Generator Factory – GDZRC series DC Winding Resistance Tester – HV Hipot

    Features ● Four leads measurement to ensure measuring accuracy. ● Program-controlled current source to increase measuring speed. ● Auto discharge and discharge indication function, to ensure safety and availability. ● LCD screen and Built-in Printer. Specifications Items Specifications Remark Testing current 1mA  10mA  1A  5A  10A   Measurement range 1mA: 10mA: 1A: 5A: 10A: 1Ω-20KΩ 1Ω-2KΩ 10mΩ-20Ω 1mΩ-4Ω 1mΩ-2Ω   GDZRC-20A DC Winding Resistance Tester Testing current 1A  5A  10A  20A Measurement range 1A: 10mΩ~20Ω 5A: 1mΩ~4Ω 10A: 1mΩ~2Ω 20A: 1mΩ~1Ω Weight About 10kg GDZRC series DC Winding Resistance Tester GDZRC-40A Testing current 2.5A  5A  10A  20A  40A Measurement range 2.5A:10mΩ-8Ω 5A: 1mΩ-4Ω 10A: 1mΩ-2Ω 20A: 1mΩ-1Ω 40A:1mΩ-500mΩ W...
  • OEM Best Online Pd Spot Tester Factories –  GD-610C Remote Ultrasonic Partial Discharge Detector – HV Hipot

    OEM Best Online Pd Spot Tester Factories – GD-610C Remote Ultrasonic Partial Discharge Detector – HV Hipot

    Partial discharge is one of the common reasons of medium and high voltage equipment and cable insulation failures. Partial discharge testing can detect harmful defects and help identify potential future failures. The GD-610C remote ultrasonic partial discharge detector uses an ultrasonic spectrum probe (sensor) to collect ultrasonic signals and analyze the signal to diagnose the charged detection, it is a diagnosis device for the accident of the distribution line. The device determines the line position and the fault type of the faulty hidden line when it is live. After collecting the ultrasonic abnormal signal, it transmits signals to the host, converts it into an audible sound signal and waveform, and finally diagnoses the type of the hidden danger and grade by the analysis software. ...