  • OEM Best Cable Identifier 128hz 262khz Manufacturer –  GDCF-900T Vehicle Mounted Cable Fault Locating System – HV Hipot

    OEM Best Cable Identifier 128hz 262khz Manufacturer – GDCF-900T Vehicle Mounted Cable Fault Locating System – HV Hipot

    Vehicle Mounted Cable Fault Locator system is used for Cable Fault conditioning (burn-down), Pre-Location, Route Location, Pin-pointing & Testing of HV & LV cables of different types&sizes. The set is suitable to carrying out the above-mentioned multifunction on power cables of various voltage levels mainly 33KV, 11KV, 415V and control cables with 1.1 KV grade. The set shall be used for cable types namely XLPE, PVC, PILC with Al / Cu conductor. The cables are laid underground (under plain earth, trenches, or RCC surface, Horizontal Drilling in HDD Pipe), above ground or partly under & partly above ground with maximum cable length around 25Km. The cable fault locator is suitable for fault locating and pinpointing the following types of cable faults. ● High resistance ● L...
  • OEM Best earthing resistance test Factory –  GD3127 Series High Voltage Insulation Resistance Tester   – HV Hipot

    OEM Best earthing resistance test Factory – GD3127 Series High Voltage Insulation Resistance Tester – HV Hipot

    General Information GD3127 Series Insulation Resistance Tester is widely used in maintenance of electrical equipment in transformer substation, power plant, etc. It is suitable for carrying out measurement of insulation resistance(IR), polarization index(PI), absorption ratio (DAR), ramp(RAMP), filter(FR, 10s, 20s, 30s, 40s 4 choices), voltage(V), current(nA) of all kinds of high voltage equipment, including switchgear, transformers, reactors, capacitors, motors, generators and cables, etc. GD3127 Series is the perfect test tool for early identification and discovery of preventive or predictive maintenance plans for potential equipment failures. It is of great significance to ensure product quality and the safety of people and equipment in operation. The insulation performance of ele...
  • OEM Best Capacitor Bank Suppliers –  30kVA.200kV Automatic AC.DC Hipot Test Set GDYD-2030A – HV Hipot

    OEM Best Capacitor Bank Suppliers – 30kVA.200kV Automatic AC.DC Hipot Test Set GDYD-2030A – HV Hipot

    Features ● 7inch color LCD screen, with PLC automation control. ● HV Voltage, LV voltage, LC current measured at the same time, with high precision sensor and high-performance collection chip. ● Automatic mode and manual mode for option. ● Display HV voltage, LV voltage, LV current, time, and withstanding result. ● Over-voltage and over-current protection. Output voltage, HV current upper limit, LV current upper limit and timing can be set. ● Zero-starting function. Test can be proceeded after the voltage is back to zero. ● Store up to 8000pcs data in 3months. It has USB port to upload data to USB disk. ● When setting voltage is arrived, it will be timing automatically. After timing, voltage will be back to zero. ● When the LV current is over setting value, the voltage will be cut of...
  • OEM Best Cable Testing Methods Suppliers –  GD-2134A Cable Identifier – HV Hipot

    OEM Best Cable Testing Methods Suppliers – GD-2134A Cable Identifier – HV Hipot

    The purpose of the cable identifier is to accurately identify one of the target cables from multiple cables and avoid serious accidents caused by wrong sawing of live cables. Cable identification starts from the operation of both ends of the cable, it must be ensured that the double number on both ends of the cable is accurate. GD-2134A Cable Identifier is only suitable for on-site identification of de-energized cables. It is strictly forbidden to connect the cable identifier to the running power cable! Features ● Handheld receiver automatically identify and display the results to ensure that the results of cable identification are 100% accurate. Light weight and powerful, easy to carry. ● Suitable for on-site identification of de-energized cables. ● Both transmitter and handheld re...
  • OEM Best Cable Fault Locating Factories –  GD-2136H Cable Fault Locating System – HV Hipot

    OEM Best Cable Fault Locating Factories – GD-2136H Cable Fault Locating System – HV Hipot

    GD2136H Cable Fault system is important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables. The system contains below units: 1. GD-2131H Impulse Generator 2. GD-2132 Cable Fault Locator 3. GD-2133 Cable Fault Tester 4. Other accessories GD-2131H Impulse Generator It’s used to generate HV impulse when using impulse flashover method to detect high impedance fault. Features ● Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased. ● If working together with GD-2133 Cable Fault Tester, there are two locating ways: a. Low voltage pulse: If only using GD-2133, open circ...
  • China High Quality Capacitor Dissipation Factor Exporters –  Turn-to-turn Surge Tester – HV Hipot

    China High Quality Capacitor Dissipation Factor Exporters – Turn-to-turn Surge Tester – HV Hipot

    GDZJ-10S Turn to Turn Surge Withstand Testerh GDZJ-10S is used to test turn-to-turn insulation strength of single phase motor, 3-phase motor, Micro motor, Special motor, electrical motor, transformer (including switching mode power supply transformer), relay and winding electrical equipment. Features It can detect below faults: ● Turn-to-turn Insulation breakdown ● Corona discharge ● Winding connection mistake ● Winding disconnection ● Turn-to-turn difference ● Short-circuit between inter-phase, winding phase, or iron core Specifications ● Peak voltage: 500-10kV continuous adjustment ● Peak error: ≤ 5%(1kV-5kV) ● Waveform rising time: 0.5μS or 0.2μS ● Power supply: 220V±10%, 50Hz ● Power consumption: ≤ 800 W ● Dimension: 900*460*550mm ● Weight: about 70kg Important Tips GDZJ...
  • OEM Best Detect Cable Fault Manufacturer –  GD-4138H Cable Fault Locating System – HV Hipot

    OEM Best Detect Cable Fault Manufacturer – GD-4138H Cable Fault Locating System – HV Hipot

    GD-4138H Mobile Cable Fault Locating System is important tool to maintain all kinds of cables. It is compatible equipment that can trace, locate the underground cables, with fault distance measurement and HV generation. As it is movable device, it is convenient to carry on-site. If acoustic locator is used together, it can locate accurate position of cable fault point. Application is underground cable, aerial cable, power cable, local cable, communication cable and fiber cable. Typical fault to be detected includes ● High impedance flash-over fault ● High impedance leak ● High/low resistive grounding ● Short-circuit fault ● Open-circuit fault ● Poor connection/Disconnection GD-4138L system includes ● GD-4138H main frame (Coupling device, Sphere gap, HV generator are inside) ● GD-...
  • China High Quality Cf4 Measurement Factory –  GDSF-311WPD 3-in-1 SF6 Gas Analyzer – HV Hipot

    China High Quality Cf4 Measurement Factory – GDSF-311WPD 3-in-1 SF6 Gas Analyzer – HV Hipot

    General Information GDSF-311WPD (GDSF-411WPD) is an ideal instrument when it is necessary to test water content, purity and decomposition products of SF6 gas. The core component of dew point test is DRYCAP®  series sensors produced by Finland Vaisala company. The infrared principle SF6 gas purity testing sensor manufactured by European Sensor Company is used to test the purity of SF6 gas. The electrochemical sensor manufactured by Mombabo Company in Switzerland is used as the sensing element for the test of SF6 gas decomposition products. With professional hardware chips and excellent software algorithms of STMicroelectronics, we have produced a new generation of 3-in-1 gas analyzer. Application Features Specification SF6 Humidity ● Measurement method: Resistive and Capaci...
  • China High Quality earth resistence measuring instruments prices Factories –  Substation Temperature Monitoring System – HV Hipot

    China High Quality earth resistence measuring instruments prices Factories – Substation Temperature Monitoring System – HV Hipot

    General Information There are usually two ways to monitor the insulation condition of high voltage electrical equipment in substations: online monitoring and live (portable) online detection. The former one can obtain the characteristic parameters reflecting the abnormal insulation of the equipment at any time, which is convenient for automatic management. However, the investment is relatively large, the installation and construction are relatively troublesome, and regular maintenance is needed. For the latter, it has the advantages of low investment, highly targeted, easy to install, maintain and update. As long as the sampling unit is installed in the electrical equipment in advance, a regular detection can be done for electrical equipment in operation, and insulation flaw can be f...
  • OEM Best partial discharge calibrator Exporters –  Partial Discharge Online Monitoring System of GIS – HV Hipot

    OEM Best partial discharge calibrator Exporters – Partial Discharge Online Monitoring System of GIS – HV Hipot

    General Information Gas-insulated metal-enclosed switches (GIS) and gas-insulated metal-enclosed transmission lines (GIL) are one of the most important devices in the power system. They have the dual tasks of control and protection. If they failed during operation and the problem cannot be solved timely,it will cause serious damage to the grid. Partial discharge fault is a common fault type of GIL/GIS. It is necessary to use GIS partial discharge online monitoring and fault location system to perform real-time online monitoring of GIL/GIS partial discharge signals and analyze and process the measured data and real time give comprehensive judgment of insulation status. Then repair schedule can be arranged according to the monitoring results to avoid major grid accidents caused by equi...
  • OEM Best Ac Voltage Capacitor Suppliers –  High voltage divider GDFR-D1 – HV Hipot

    OEM Best Ac Voltage Capacitor Suppliers – High voltage divider GDFR-D1 – HV Hipot

    GDFR-D1 series AC/DC Voltage Meter GDFR-D1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. The digital meter and divider are equipped in one unit.  Features ● Balance type equal potential shield structure. ● Fully-sealed insulation cylinder with internal excellent components. ● High accuracy and linearity, good stability and anti-interference ability. ● With good filling materials, which make the structure smaller and weight lighter, and minimize internal partial discharge. ● Small size, light weight, easy to carry in the field work. ● Inner shield anti-interference system. ● The voltage ratio can be customized, suitable for calibration. ● External voltage meter can be connected. Technical Specifications Model No. GDFR-D1-50 GDFR-D1-100 G...
  • China High Quality Reference Capacitor Factory –  VLF AC Hipot Test Set – HV Hipot

    China High Quality Reference Capacitor Factory – VLF AC Hipot Test Set – HV Hipot

    Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test. AC test can be further divided into power frequency, variable frequency and 0.1Hz very low frequency test, among which the last one is highly recommended by IEC, due to its remarkable advantages. Following is a comparison for DC, Power Frequency, Variable Frequency, and 0.1Hz test. Aspects DC Power Frequency Variable Frequency 0.1Hz Equivalency poor good good good Insulation Damage strong slight slight slight Operation Safety relatively low relatively low relatively low high Wiring Difficulty complicated complicated most complicated simple Volume smallest largest large smal...