Featured

  • China High Quality Cable And Pipe Locator Suppliers –  GD-2134E  Cable Identifier – HV Hipot

    China High Quality Cable And Pipe Locator Suppliers – GD-2134E Cable Identifier – HV Hipot

    GD-2134E is a high-performance underground metal pipeline detection system composed of signal transmitters and receivers. It can be used for path detection, pipeline survey and depth measurement of metal pipelines and underground cables. It can carry out uniqueness identification with a variety of selected accessories, as well as pipe insulation damage and the search for some types of cable faults. Features ● Compass display: intuitively displays the pipeline location and left & right directions. ● Tracking true and false prompts: current direction measurement, tracking correct error prompts, eliminating line interference (some frequencies). ● Depth and current measurements, can display the signal strength historical curve. ● Fully digital high-precision sampling processing: sta...
  • OEM Best Mccb Circuit Breaker Exporters –  GDSL-BX-200 Primary Current Injection Test Set – HV Hipot

    OEM Best Mccb Circuit Breaker Exporters – GDSL-BX-200 Primary Current Injection Test Set – HV Hipot

    Features ● Digital control, high anti reference ability. ● Adapts autotransformer regulator which with low power consumption and large capacitance. ● Converter has high permeability core. ● Quick connects, lock design, have good current capability. ● PVC panel. ● Build-in quick plug with high safety. ● Current range can be changed, easy to read. ● Engineering plastics box, IP67 dustproof and waterproof. ● Portable design is suitable for on-site testing. ● Zero start function to prevent the test objects from damage caused by high current impulsing. The equipment only can be started at zero. ● Impulse choosing function: The current value can be outputted directly without zero protection function when the equipment is under the testing for circuit breaker. ● 0-50A AC current can be outp...
  • OEM Best electrical resistance test Factory –  GD2000H 10kV Insulation Resistance Tester – HV Hipot

    OEM Best electrical resistance test Factory – GD2000H 10kV Insulation Resistance Tester – HV Hipot

    General Information This device can test insulation resistance (such as transformer, switchgear, leads, motor) of different modules in one system, to insulate and repair failure components. It is important to ensure products quality and security of person and equipment during operation by insulation test of checking test object to ground or adjacent conductors’ insulation. Before power on the system, use insulation test to verify if it is good to improve system performance. Insulation test is to find manufacturing process problems and equipment fault which can’t be found before failure happened. In EU, this test is compulsory, even to civil system. Features 1. Voltage output GD2000H (5kV/10kV).Resistance range 0-400GΩ. 2. Two modes display insulation resistance. 3. Aut...
  • OEM Best Power Cable Fault Location Suppliers –  GD-2136H Cable Fault Locating System – HV Hipot

    OEM Best Power Cable Fault Location Suppliers – GD-2136H Cable Fault Locating System – HV Hipot

    GD2136H Cable Fault system is important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables. The system contains below units: 1. GD-2131H Impulse Generator 2. GD-2132 Cable Fault Locator 3. GD-2133 Cable Fault Tester 4. Other accessories GD-2131H Impulse Generator It’s used to generate HV impulse when using impulse flashover method to detect high impedance fault. Features ● Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased. ● If working together with GD-2133 Cable Fault Tester, there are two locating ways: a. Low voltage pulse: If only using GD-2133, open circ...
  • OEM Best Discharge Ac Capacitor With Multimeter Factories –  30kVA.200kV Automatic AC.DC Hipot Test Set GDYD-2030A – HV Hipot

    OEM Best Discharge Ac Capacitor With Multimeter Factories – 30kVA.200kV Automatic AC.DC Hipot Test Set GDYD-2030A – HV Hipot

    Features ● 7inch color LCD screen, with PLC automation control. ● HV Voltage, LV voltage, LC current measured at the same time, with high precision sensor and high-performance collection chip. ● Automatic mode and manual mode for option. ● Display HV voltage, LV voltage, LV current, time, and withstanding result. ● Over-voltage and over-current protection. Output voltage, HV current upper limit, LV current upper limit and timing can be set. ● Zero-starting function. Test can be proceeded after the voltage is back to zero. ● Store up to 8000pcs data in 3months. It has USB port to upload data to USB disk. ● When setting voltage is arrived, it will be timing automatically. After timing, voltage will be back to zero. ● When the LV current is over setting value, the voltage will be cut of...
  • OEM Best energy meter calibration equipment Factories –  GDYB-S3 Three Phase Energy Meter Test System (3 positions) – HV Hipot

    OEM Best energy meter calibration equipment Factories – GDYB-S3 Three Phase Energy Meter Test System (3 positions) – HV Hipot

    Technical Specification System accuracy: 0.1%; Three phase source parameter: a. Output voltage: 3*57.7VY 3*100V ∆ ; 3*220V Y 3*380V ∆; Adjustable range 0~120% continuously adjustable Adjustment fineness: better than 0.01% b. Output current: 25mA, 0.1A, 1A, 5A, 25A,100A; Adjustable range 0~120% continuously adjustable Adjustment fineness: better than 0.01% Mininum output current: 1mA (accuracy: <5%) c. Output power: (voltage circuit) 3 * 50VA (current circuit) 3 * 150VA d. Output voltage, current, power stability: ≤0.02%/120S e. Distortion degree of output voltage and current waveform: ≤0.5% f. Symmetry of three phase angles: between 120°±0.3° g. Frequency range: 45Hz~ 65Hz, step: 0.01Hz h. Phase angle range: -180°~ 180°, step: 0.01° i. Indicating metter accuracy: V...
  • OEM Best digital megohmmeter Supplier –  Dielectric Loss Tester for Live Capacitive Equipment GDDJ-HVC  – HV Hipot

    OEM Best digital megohmmeter Supplier – Dielectric Loss Tester for Live Capacitive Equipment GDDJ-HVC – HV Hipot

    General Information There are usually two ways to monitor the insulation condition of high voltage electrical equipment in substations: online monitoring and live (portable) online detection. The former one can obtain the characteristic parameters reflecting the abnormal insulation of the equipment at any time, which is convenient for automatic management. However, the investment is relatively large, the installation and construction are relatively troublesome, and regular maintenance is needed. For the latter, it has the advantages of low investment, highly targeted, easy to install, maintain and update. If the sampling unit is installed in the electrical equipment in advance, a regular detection can be done for electrical equipment in operation, and insulation flaw can be found in ...
  • OEM Best manufacturers of dew point measuring instruments Factories –  GDZL-503 Automatic Interfacial Tension tester – HV Hipot

    OEM Best manufacturers of dew point measuring instruments Factories – GDZL-503 Automatic Interfacial Tension tester – HV Hipot

    Intermolecular forces will generate interface tension and surface tension of liquids. The value of tension reflects liquid sample’s physics and chemical properties, which is one of the most important index for product quality. GDZL-503 automatic interfacial tension tester tests kinds of liquid surface tension and interface tension according to ring method which is simple and accurate. It is widely used in electric, petroleum, chemical,medicine, food and teaching filed. Features ● Exclusive and quick response electromagnetic balance sensor is adopted, to improve the accuracy of the measurement and degree of linearity. ● Only using one point calibration, to solve the problem of previous sensor which needs multi-point calibration. It is no need to use zero potentiometer and full s...
  • China High Quality Cable And Pipe Locator Factories –  GD-2134E  Cable Identifier – HV Hipot

    China High Quality Cable And Pipe Locator Factories – GD-2134E Cable Identifier – HV Hipot

    GD-2134E is a high-performance underground metal pipeline detection system composed of signal transmitters and receivers. It can be used for path detection, pipeline survey and depth measurement of metal pipelines and underground cables. It can carry out uniqueness identification with a variety of selected accessories, as well as pipe insulation damage and the search for some types of cable faults. Features ● Compass display: intuitively displays the pipeline location and left & right directions. ● Tracking true and false prompts: current direction measurement, tracking correct error prompts, eliminating line interference (some frequencies). ● Depth and current measurements, can display the signal strength historical curve. ● Fully digital high-precision sampling processing: sta...
  • OEM Best lightning protection system Manufacturer –  GDYZ-301 Zinc Oxide Surge Arrester Tester  – HV Hipot

    OEM Best lightning protection system Manufacturer – GDYZ-301 Zinc Oxide Surge Arrester Tester – HV Hipot

    Features 1. 800*480 color LCD touch screen, with high speed thermal printer. 2. Graphic display, intuitive interface, easy to operate and use on-site. 3. Long distance wireless transmission. PT signal wireless transmission distance more than 400m (2000m can be customized). 4. Suitable for testing in various situation such as lightning arrester with or without electricity, laboratory. 5. Test three phase current, three phase voltage at the same time, more efficient. 6. No strong electricity inside, voltage not more than 12V. Current and voltage sensors are completely isolated, safe and reliable. 7. Support various voltage sampling: 1. Wired; 2 wireless; 3. Non-voltage; A. Wire: digital signal transmission with cable which the signal is from PT metering winding; B. Wireless: digital s...
  • OEM Best Testing Ac Capacitor Suppliers –  DC High Voltage Generator GDZG-300 – HV Hipot

    OEM Best Testing Ac Capacitor Suppliers – DC High Voltage Generator GDZG-300 – HV Hipot

    Features ● Simple operation and complete function, easy for wild work. ● Higher voltage stability, smaller ripple coefficient. ● More reliable and stable, continuous short-circuit discharge directly to ground. ● Intelligent grounding protection and alarm function. High precision, accurate measurement, digital display of voltmeter and ammeter, with voltage resolution 0.1kV, and current 0.1uA. ● High stability of voltage regulation, smooth voltage boosting process, high adjustable precision, with coarse and fine adjustment functions. Accuracy of voltage regulation better than 0.1%, voltage and current measurement error is less than 1.0%, ripple factor better than 0.5%. ● With function of high-accuracy 75%VDC-1mA, more convenient for zinc oxide lighting arrester DC testing. ● HV booste...
  • China High Quality megger insulation tester 1000v Supplier –  GDF-3000A  DC System Earth Fault Detector – HV Hipot

    China High Quality megger insulation tester 1000v Supplier – GDF-3000A DC System Earth Fault Detector – HV Hipot

    General Information DC system insulation faults, DC mutual faults and AC power failures are faults that are prone to occur and are harmful to the power system, and endanger the normal operation of the power system. In order to better help field maintenance personnel to quickly and accurately find DC faults, our company has developed a DC fault finder by years of efforts and summing up a large number of field experiences. The DC grounding finder uses a high-precision current clamp meter to detect and locate faults using the DC current difference in the fault loop. The fast FFT transform technology is introduced into the DC fault finding device, to detect various types of insulation faults, DC mutual faults, and AC power failures in DC systems with different voltage level (24V (optiona...