OEM Best Cable Locator Suppliers – GD-4136H Cable Fault Locating System – HV Hipot
GD4136H Cable Fault system is an important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables. The system contains below units: 1.GD-2131H Impulse Generator 2.GD-4132 Cable Fault Locator 3.GD-4133 Multi-pulse Cable Fault Detector 4.GD-4133S Multi-pulse Coupler 5.Other accessories GD-2131H Impulse Generator It’s used to generate HV impulse when using impulse flashover method to detect high impedance fault. Features ● Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased. ● If working together with GD-4133 Cable Fault Tester, there are two locating ways: a. Low vol... -
OEM Best testing of instrument transformer Factories – GDPD-306M Portable Ultrasonic Partial Discharge Detector – HV Hipot
GDPD-306M is widely used in the partial discharge detection of power systems. Including high voltage switchgear, ring mains, voltage/current transformer, transformer (include dry type transformer), GIS, overhead lines, cables, and other equipment insulation state detection. The following indicators are used to measure the degree of discharge of electrical equipment: Partial discharge intensity detection: By measuring the discharge signal in a power frequency cycle, the intensity of the partial discharge is characterized according to the maximum value (dB) in the discharge pulse sequence. Partial discharge frequency detection: The device measures the discharge signal within a power frequency cycle, extracts the discharge pulses and characterizes the frequency of partial discha... -
China High Quality Routine Test Of Circuit Breaker Supplier – GDHL-200B / GDHL-500B / GDHL-600B Contact Resistance Tester (Microhm meter) – HV Hipot
Features ● Output high-current continuously. ● Quick and accurate test. Test current is generated from high-precision 100A/200A switching mode constant current power supply, no need for manual adjustment. ● Adopts four-terminal wiring method. The influence of test line resistance on test results is effectively eliminated. ● Stable performance. There is over-heat protection crcuit designed for long-time working. ● Light weight, easy to carry and operate. Specifications GDHL-500B Contact Resistance Tester (Micro-ohm Meter) Specifications Accessories Main unit 1 set Test wire 4 pieces Power cord 1 piece Print paper 2 rolls Ground cable 1 piece User’s guide 1 copy Test Report 1 copy GDHL-600B Contact Resistance Tester (Micro-oh... -
OEM Best Cable Detector Exporters – GD-7018A Optical Fiber Identifier – HV Hipot
The GD-7018 series optical fiber pipeline identifier can accurately locate and meaure depth of the underground pipelines, cables and optical cables under the condition of without digging, and accurately find the damage points of the outer coating of the underground pipelines and the location of the underground cable fault points. The instrument incorporates the most advanced technologies such as ultra-narrow band filter, Bluetooth wireless communication, GPS positioning, automatic data mapping by professional data analysis software and automatic generation of test reports. The detection and inspection of various kinds of metal pipelines, pipeline management and maintenance, municipal planning and construction, pipeline inspection in power supply and other departments is one of the neces... -
China High Quality 4000 Amps Primary Injection Test Kit Online Sale Factory – GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot
Adoption of Standard ● DL/T 596-2005 “Procedure Test Procedures for Electrical Equipment” ● GB1094.1-GB1094.6-96 “Shell protection level” ● GB2900 “Electrical Terminology” ● GB/T16927.1~2-1997 “High Voltage Test Technology” ● GB4793-1984 “Safety Requirements for Electronic Measuring Instruments” ● GB191 “Package Storage and Transportation Mark” ● GB/T.311-1997 “Insulation and coordination of high voltage power transmission and transformation equipment” Features ● Using high conductivity copper as the output electrode, the contact surface is large and the flow capacity is strong. ● Brushed aluminum plate with a new process, simple and eye-catching, wear-resistant and pollution-resistant. ● The all-... -
China High Quality Multistage Impulse Generator Factories – GDOT-100D 100kV Insulation Oil Tester – HV Hipot
General Information In power system, railway system and large petrochemical industrial enterprises all have a lot of electrical equipment, its internal insulation is mostly oil-filled insulation type. Dielectric strength test for insulating oil is a routine test which shall be measured. In order to meet the market needs. Our company self-developed and produced GDOT series dielectric strength tester for insulation oil according to national standard GB/T5072002, industrial standard DL429.991 and the latest electric power industry standard DL/T846.7- 2004. The instrument use single chip microcomputer as the core, to achieve full automatic testing and high precision measurement, greatly improves the work efficiency and also reduce the labor intensity of the workers greatly. Featu... -
OEM Best A Coupling Capacitor Is Supplier – AC Dielectric Test Equipment with manual control unit GDYD-M – HV Hipot
Application AC Hipot testing is the effective and direct way to test insulation strength for electric equipment, apparatus, or machines. It checks dangerous flaws which assure electric equipment continuous working. Typical applications include testing of transformers, switchgear, cables, capacitors, aerial motors platforms, hot sticks bucket bricks, vacuum bottles and other related equipment like vacuum interrupters, blankets, ropes, gloves, hydraulics hose, instruments transformers generators. Features ● Pointer display panel mounted controls & indicators with easy-to-read legend. ● Monitoring high voltage side voltage, low voltage side current and indicator of zero, power, working start, timing. ● Over-current protection, zero-starting protection, sound, and light alarm. ● C... -
OEM Best Cable Finder Factory – GD-2134E Cable Identifier – HV Hipot
GD-2134E is a high-performance underground metal pipeline detection system composed of signal transmitters and receivers. It can be used for path detection, pipeline survey and depth measurement of metal pipelines and underground cables. It can carry out uniqueness identification with a variety of selected accessories, as well as pipe insulation damage and the search for some types of cable faults. Features ● Compass display: intuitively displays the pipeline location and left & right directions. ● Tracking true and false prompts: current direction measurement, tracking correct error prompts, eliminating line interference (some frequencies). ● Depth and current measurements, can display the signal strength historical curve. ● Fully digital high-precision sampling processing: sta... -
OEM Best instrument transformers are Factories – Partial Discharge Online Monitoring System of GIS – HV Hipot
General Information Gas-insulated metal-enclosed switches (GIS) and gas-insulated metal-enclosed transmission lines (GIL) are one of the most important devices in the power system. They have the dual tasks of control and protection. If they failed during operation and the problem cannot be solved timely,it will cause serious damage to the grid. Partial discharge fault is a common fault type of GIL/GIS. It is necessary to use GIS partial discharge online monitoring and fault location system to perform real-time online monitoring of GIL/GIS partial discharge signals and analyze and process the measured data and real time give comprehensive judgment of insulation status. Then repair schedule can be arranged according to the monitoring results to avoid major grid accidents caused by equi... -
OEM Best Cable Fault Finder Exporters – GD-2136H Cable Fault Locating System – HV Hipot
GD2136H Cable Fault system is important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables. The system contains below units: 1. GD-2131H Impulse Generator 2. GD-2132 Cable Fault Locator 3. GD-2133 Cable Fault Tester 4. Other accessories GD-2131H Impulse Generator It’s used to generate HV impulse when using impulse flashover method to detect high impedance fault. Features ● Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased. ● If working together with GD-2133 Cable Fault Tester, there are two locating ways: a. Low voltage pulse: If only using GD-2133, open circ... -
China High Quality closed cup flash point determine Supplier – GDW-106 Oil Dew Point Tester User’s Guide – HV Hipot
Caution ● The following instructions are used by qualified person to avoid electrical shock. Do not perform any service beyond operation instructions unless you are qualified to do so. ● Don’t operate this device in flammable and moist environment. Keep the surface clean and dry. ● Please make sure the equipment is upright before opening. Don’t drop equipment heavily avoid equipment movement damage. ● Place the equipment in dry, clean, ventilated area free from corrosive gas. Stacking equipment without transit containers is dangerous. ● Panel should be upright during storage. Elevate stored items to protect from moisture. ● Don’t disassemble the instrument without permission, which will affect the warranty of the product. The factory is not responsible for self-dism... -
OEM Best partial discharge calibrator Exporters – GDPD-3000C Portable Partial Discharge Detector – HV Hipot
GDPD-3000C Portable Ultrasonic Partial Discharge Detector uses advanced cloud computing and automatic modeling technology to achieve the partial discharge signal measurement, recording, transmission, storage, analysis and exchange, providing powerful technical support for on-site measurement of partial discharge. The measurement personnel collect the partial discharge information by using GDPD-3000C, and the cloud computing can be used to intelligently diagnose the insulation state of detection equipment in real time. Specification Hardware ● Processor: high performance intelligent processor. ● Screen: 4.3inch Touch Screen. ● Operation keys: PVE film keyboard. ● Interface: ● 3.5mm stereo headphone interface ● DC LV current charging interface ● USB 2.0 3G wireless network in...