OEM Best lubricant oil acid test Factory – GDW-102 Oil Dew Point Tester (Coulometric Karl Fischer Titrator) – HV Hipot
Coulometric Karl Fischer technology is applied to measure precisely trace moisture the measured sample contains.The technology is widely used for accuracy and cheap test cost.The Model GDW-102 measure precisely trace moisture on liquid, solid and gas samples according to the technology. It’s used in electricity, petroleum, chemicals, foods and so on. Features ● Use improved PWM electrolysis circuit to reduce the power dissipation of the instrument. ● High precise measuring electrode signal and circuit detection make the electrolytic end decision quickly and precisely with strong anti-interference ability. ● Use methods of electrolyte blank current compensation and electrolyte balance drift compensation to devise testing result. ● Built in three calculation formula to generate r... -
OEM Best high voltage cable testing equipment Manufacturer – GDPD-414H Handheld Partial Discharge Detector – HV Hipot
Pictures for reference only. The GDPD-414H handheld Partial Discharge Detector adopts smart quick intelligent power test system (Soft No. 1010215, trademark registration number 14684481). It can flexibly configure various sensors according to different products to be tested. TEV, ultrasonic and HFCT are suitable for partial discharge detection of high-voltage switchgear and ring network cabinet; Ultrasonic and UHF are suitable for detecting GIS; Ultrasonic and HFCT are suitable for testing power cable. The built-in expert diagnosis system can analyze the test data and judge the discharge energy and possible parts. It is widely used in electric power and railway. Features ● Portable ABS engineering chassis. All PD detection hosts, tablets, sensors, chargers and signal cables are placed... -
China High Quality pd sensor Supplier – GDPD-3000C Portable Partial Discharge Detector – HV Hipot
GDPD-3000C Portable Ultrasonic Partial Discharge Detector uses advanced cloud computing and automatic modeling technology to achieve the partial discharge signal measurement, recording, transmission, storage, analysis and exchange, providing powerful technical support for on-site measurement of partial discharge. The measurement personnel collect the partial discharge information by using GDPD-3000C, and the cloud computing can be used to intelligently diagnose the insulation state of detection equipment in real time. Specification Hardware ● Processor: high performance intelligent processor. ● Screen: 4.3inch Touch Screen. ● Operation keys: PVE film keyboard. ● Interface: ● 3.5mm stereo headphone interface ● DC LV current charging interface ● USB 2.0 3G wireless network in... -
China High Quality plash point tester Manufacturers – GDFJ-VI Transformer Dissolved Gas Analyzer – HV Hipot
General Information GDFJ-VI Transformer Dissolved Gas Analyzer is a portable gas chromatograph suitable for on-site rapid analysis. It integrates chromatographic detection, analysis and diagnosis in one, as well as micro detector, mini gas source and built-in touch screen computer. It has higher integration, better stability, more delicate shape and more convenient operation than traditional portable oil chromatography. On-site analysis can timely analyze and diagnose transformer fault conditions, making power work simpler and more convenient. The instrument adopts the classical three-detector process, and the analytical data are identical with those of the traditional laboratory chromatograph. The instrument adopts advanced small modular design concept. It has high integration, sma... -
China High Quality Tdr Tester Factories – GD-2134E Cable Identifier – HV Hipot
GD-2134E is a high-performance underground metal pipeline detection system composed of signal transmitters and receivers. It can be used for path detection, pipeline survey and depth measurement of metal pipelines and underground cables. It can carry out uniqueness identification with a variety of selected accessories, as well as pipe insulation damage and the search for some types of cable faults. Features ● Compass display: intuitively displays the pipeline location and left & right directions. ● Tracking true and false prompts: current direction measurement, tracking correct error prompts, eliminating line interference (some frequencies). ● Depth and current measurements, can display the signal strength historical curve. ● Fully digital high-precision sampling processing: sta... -
China High Quality Capacitor Tester Manufacturer – VLF AC Hipot Test Set 80kV – HV Hipot
Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test. AC test can be further divided into power frequency, variable frequency and 0.1Hz very low frequency test, among which the last one is highly recommended by IEC, due to its remarkable advantages. Following is a comparison for DC, Power Frequency, Variable Frequency, and 0.1Hz test. Aspects DC Power Frequency Variable Frequency 0.1Hz Equivalency poor good good good Insulation Damage strong slight slight slight Operation Safety relatively low relatively low relatively low high Wiring Difficulty complicated complicated most complicated simple Volume smallest largest large smal... -
OEM Best Capacitor Testing Machine Supplier – AC Resonant Test System for Generators GDTL – HV Hipot
GDTL series AC Resonant Test System for Generators can be used by adjusting inductance of the reactor, or adjusting the work way of resonant frequency of the system to achieve resonance. Both two methods can be used to achieve resonance. In the voltage boosting process, if the resonant point deviate, it can be found exactly by the way of fine tuning frequency, which ensure a high Q value and reduce power capacity and volume weight of test equipment. Features ● Smaller size,lighter weight compared with same voltage level,same capacity generator AC withstand voltage test equipment.Single equipment is no more than 60kg, easy to move. ● Advanced principle of whole set device and new frequency & inductance modulation technology, strictly ensure generator power frequency withstand volt... -
China High Quality to test earth resistance Exporters – GDWR-5A Earth Resistance Tester for Ground Grid – HV Hipot
Product Description GDWR-5A Earth Resistance Tester is a high-precision test instrument used in various fields such as substations for testing grounding resistance and related parameters. The instrument has the characteristics of small volume, light weight, convenient carrying, strong anti-interference performance and high accuracy. The instrument is an integrated structure, built-in variable frequency power supply module, and the output power supply is continuously variable frequency adjustable. The frequency can be changed to 45Hz or 55Hz, and the built-in high-speed processor core adopts high-end digital filtering technology, which effectively avoids the interference of the power frequency electric field to the test, and fundamentally solves the problem of accurate measurement und... -
China High Quality Single Stage Impulse Generator Circult Supplier – GDZRC series DC Winding Resistance Tester – HV Hipot
Features ● Four leads measurement to ensure measuring accuracy. ● Program-controlled current source to increase measuring speed. ● Auto discharge and discharge indication function, to ensure safety and availability. ● LCD screen and Built-in Printer. Specifications Items Specifications Remark Testing current 1mA 10mA 1A 5A 10A Measurement range 1mA: 10mA: 1A: 5A: 10A: 1Ω-20KΩ 1Ω-2KΩ 10mΩ-20Ω 1mΩ-4Ω 1mΩ-2Ω GDZRC-20A DC Winding Resistance Tester Testing current 1A 5A 10A 20A Measurement range 1A: 10mΩ~20Ω 5A: 1mΩ~4Ω 10A: 1mΩ~2Ω 20A: 1mΩ~1Ω Weight About 10kg GDZRC series DC Winding Resistance Tester GDZRC-40A Testing current 2.5A 5A 10A 20A 40A Measurement range 2.5A:10mΩ-8Ω 5A: 1mΩ-4Ω 10A: 1mΩ-2Ω 20A: 1mΩ-1Ω 40A:1mΩ-500mΩ W... -
OEM Best Capacitance Tester Suppliers – VLF AC Hipot Test Set 80kV – HV Hipot
Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test. AC test can be further divided into power frequency, variable frequency and 0.1Hz very low frequency test, among which the last one is highly recommended by IEC, due to its remarkable advantages. Following is a comparison for DC, Power Frequency, Variable Frequency, and 0.1Hz test. Aspects DC Power Frequency Variable Frequency 0.1Hz Equivalency poor good good good Insulation Damage strong slight slight slight Operation Safety relatively low relatively low relatively low high Wiring Difficulty complicated complicated most complicated simple Volume smallest largest large smal... -
OEM Best megger Exporters – GDHX-9500 Phase Detector – HV Hipot
General Information GDHX-9500 Phase Detector is mainly used in electric power lines, phase and phase sequence calibration in substation, with main functions including electrical inspection, phase calibration and phase sequence measurement. It uses double shielding and brand new digital circuits, with strong anti-interference, accorded with EMC standards, suitable for various electromagnetic interference situations. The high voltage phase signal of measured lead will be transmitted directly after treatment, the handset will receive and make phase comparison, determine the results after phase detection, real-time display phase angle difference and vector.It uses wireless transmission technology, safe and reliable, fast and accurate, suitable for using at different voltage levels (6V-50... -
OEM Best Capacitor Tester Price Suppliers – AC Inductance Resonance Test System for CVT – HV Hipot
GDTL AC Resonant Test System for CVT is series resonance with power frequency specially for CVT. It is smaller size and more lighter weight than traditional device, meet various CVT inspection requirements of voltage with 35kV, 66kV, 110kV, 220kV, 330kV, 500kV. According to customer’s requirement, the reactor can be divided into fixed and adjustable reactor. Features ● Small size, light weight, simple wiring. ● Dry or Oil type reactor, high mechanical strength, good insulation, high reliability. ● Large capacity margin, good output waveform, easy to operate. ● Fully protection function: zero protection, over-voltage protection, over-current protect functions.