OEM Best dissolved gas analysis Supplier – GDND-800 Freezing Point Tester – HV Hipot
General Information 1. Transformer oil freezing point tester has the characteristics of exquisite structural design and unique manufacturing process. It conforms to GB/T 3535 and GB/T510 standards and is used to determine the pour point of petroleum products. 2. This instrument adopts compressor refrigeration technology to save energy, simple operation and long service life. Its main technical indicators such as cooling rate and cooling capacity have surpassed similar foreign products. Working conditions 1. The instrument should be placed on a flat and stable workbench, and air convection should be minimized in the environment. 2. This product may involve flammable materials when used. It is not allowed to have an open flame (or a device that produces spark) close to it during op... -
China High Quality Impulse Generator Manufacturers – GDCY Impulse Voltage Test System (100kV-7200kV) – HV Hipot
Application This impulse test system is used for carrying out full wave lightning impulse voltage tests on HV apparatus such as clearance, bushings, capacitors, switches, power transformers(capacity below 5000kVA), CT/PT at 35kV or below. Operating Condition ● Altitude: 1000m. ● Ambient Temperature: -5℃~+45℃. ● Max. daily difference temperature: ≤25℃. ● Relative humidity: <90%. ● Anti-shock ability: ≤ level 7. ● Horizontal acceleration of the ground: 3.0m/s2, Vertical acceleration of the ground: 1.5m/s2. ● Waveform of power supply voltage wave is sine actually, and the waveform distortion rate<3%. ● It should be grounded reliably, ground resistance <0.5Ω. ● Usage environment: indoor. No conductive dust, No fire and explosion, No corrosive metal and insulation gas. Applied Sta... -
OEM Best Leak Testing Machine Suppliers – GDWS-311RC SF6 Gas Dew Point Tester – HV Hipot
General Information GDWS-311RC is ideal instrument to test dew point of SF6 gas. The core component is DRYCAP series sensors produced by Finland Vaisala company. With professional hardware chips and excellent software algorithms of STMicroelectronics, we have produced a new generation of gas moisture test instrument. Application ● Moisture monitoring of SF6 gas electrical equipment for electric power ● SF6 gas cylinder gas quality test ● High purity gas manufacturing ● Semiconductor industry dry gas supply ● Research and development use ● Clean room/dry house monitoring ● Metal heat treatment site and laboratory industrial gas humidity detection, such as air, CO2, N2, H2, O2, SF6, He, Ar and other inert gases. Features ● Better than ±2℃ measurement accuracy. ● All gas path are ... -
China High Quality Sheath Fault For High Voltage Cable Manufacturer – GD-2134A Cable Identifier – HV Hipot
The purpose of the cable identifier is to accurately identify one of the target cables from multiple cables and avoid serious accidents caused by wrong sawing of live cables. Cable identification starts from the operation of both ends of the cable, it must be ensured that the double number on both ends of the cable is accurate. GD-2134A Cable Identifier is only suitable for on-site identification of de-energized cables. It is strictly forbidden to connect the cable identifier to the running power cable! Features ● Handheld receiver automatically identify and display the results to ensure that the results of cable identification are 100% accurate. Light weight and powerful, easy to carry. ● Suitable for on-site identification of de-energized cables. ● Both transmitter and handheld re... -
OEM Best one of the type of partial discharge is Manufacturer – Partial Discharge Online Monitoring System of Generators – HV Hipot
General Information Generally, partial discharge occurs at a position where the properties of the dielectric material are not uniform. At these locations, the local electric field strength is enhanced, and local electric field strength is too large, resulting in local breakdown. This partial breakdown is not the total breakdown of the insulating structure. Partial discharges typically require a certain amount of gas space to develop, such as gas voids inside the insulation, adjacent conductors, or insulating interfaces. When the local field strength exceeds the dielectric strength of the insulating material, a partial discharge occurs, causing many partial discharge pulses to occur during one cycle of applying the voltage. The amount of discharge delivered is closely related to the n... -
OEM Best Cable Testing Suppliers – GDCF-900T Vehicle Mounted Cable Fault Locating System – HV Hipot
Vehicle Mounted Cable Fault Locator system is used for Cable Fault conditioning (burn-down), Pre-Location, Route Location, Pin-pointing & Testing of HV & LV cables of different types&sizes. The set is suitable to carrying out the above-mentioned multifunction on power cables of various voltage levels mainly 33KV, 11KV, 415V and control cables with 1.1 KV grade. The set shall be used for cable types namely XLPE, PVC, PILC with Al / Cu conductor. The cables are laid underground (under plain earth, trenches, or RCC surface, Horizontal Drilling in HDD Pipe), above ground or partly under & partly above ground with maximum cable length around 25Km. The cable fault locator is suitable for fault locating and pinpointing the following types of cable faults. ● High resistance ● L... -
OEM Best power consumption of monitor Manufacturers – GDPQ-5000 Power Quality Analyzer – HV Hipot
Introduction GDPQ-5000 Power Quality Analyzer is a comprehensive test instrument carefully developed by our company and specially designed for field test of three phases, multi-functional and intelligent, concise man-machine operation. It is easy to use, large LCD screen display, high resolution, interface in both Chinese and English, shock-proof shell structure and so on. Can simultaneously measure the 4-channel current (ABC three phase and neutral wire current), 4-channel voltage (ABC three-phase voltage and neutral line voltage to ground), the peak value of current voltage, maximum/minimum value over a period, three-phase imbalance factor, short-time voltage flicker, transformer K factor, active power, reactive power, apparent power, power factor and displacement power factor, act... -
OEM Best flash point tester from china Exporters – GDBS-305 Automatic Flash Point Closed Cup Tester – HV Hipot
General Information GDBS-305 automatic closed cup flash point tester is the device testing closed cup flash point for petroleum products. It use module design which one host can control several testing furnace, to test different samples at the same time or separately. The testing furnace port can be connected to the host disorderly. It widely used in the field of railway, air company, power, petroleum and research department. Features ● 320*240 TFT LCD screen. ● With high speed signal processor control, reliable and high accuracy. ● One host can control several test furnace to test several samples at one time, which will save testing time. ● Automatic ignition with no gas source ignition mode. ● Built-in atmosphere pressure sensor, auto-measure and calibrate result. ● Self-adapti... -
China High Quality Capacitor Analyzer Manufacturers – AC Dielectric Test Equipment with manual control unit GDYD-M – HV Hipot
Application AC Hipot testing is the effective and direct way to test insulation strength for electric equipment, apparatus, or machines. It checks dangerous flaws which assure electric equipment continuous working. Typical applications include testing of transformers, switchgear, cables, capacitors, aerial motors platforms, hot sticks bucket bricks, vacuum bottles and other related equipment like vacuum interrupters, blankets, ropes, gloves, hydraulics hose, instruments transformers generators. Features ● Pointer display panel mounted controls & indicators with easy-to-read legend. ● Monitoring high voltage side voltage, low voltage side current and indicator of zero, power, working start, timing. ● Over-current protection, zero-starting protection, sound, and light alarm. ● C... -
OEM Best Impulse Voltage Test Factory – GDCY-20B 20kV Impulse Voltage Tester (Basic Type) – HV Hipot
GDCY-12B Programmable Automatic Impulse Voltage Tester is mainly based on TB/T 2653, GB/T 17627, GB/T 16927, GB14048, GB7251, GB/T 16935, IEC 61730, GB4706, GB3048, JB/T 7083 and other standard requirements. It is mainly used for safety performance (dielectric performance) detection of low-voltage electrical appliances, high and low voltage switches, solar energy, electricity meters, relays, leakage protectors, etc. The impulse output can be controlled by computer, and the test report can be printed and generated. (Picture only for reference first.) Features ● Manual/automatic/programmable mode: Manual mode adjusts impulse voltage manually by adjusting knob; Automatic mode adjusts impulse voltage automatically by the system; Programmable mode uses computer to control impulse vo... -
OEM Best Generation Of Impulse Voltage Exporters – GDCY Impulse Voltage Test System (100kV-7200kV) – HV Hipot
Application This impulse test system is used for carrying out full wave lightning impulse voltage tests on HV apparatus such as clearance, bushings, capacitors, switches, power transformers(capacity below 5000kVA), CT/PT at 35kV or below. Operating Condition ● Altitude: 1000m. ● Ambient Temperature: -5℃~+45℃. ● Max. daily difference temperature: ≤25℃. ● Relative humidity: <90%. ● Anti-shock ability: ≤ level 7. ● Horizontal acceleration of the ground: 3.0m/s2, Vertical acceleration of the ground: 1.5m/s2. ● Waveform of power supply voltage wave is sine actually, and the waveform distortion rate<3%. ● It should be grounded reliably, ground resistance <0.5Ω. ● Usage environment: indoor. No conductive dust, No fire and explosion, No corrosive metal and insulation gas. Applied Sta... -
China High Quality insulation testing Factory – GDPD-414 Portable Partial Discharge Detector – HV Hipot
Main unit UHF sensor, round type, suitable for GIS UHF sensor, rectangle type, suitable for power cable, transformer, switchgear HFCT, suitable for power cable, transformer TEV sensor, suitable for switchgear Ultrasonic sensor, suitable for transformers, switchgear Above pictures are only for reference first. The GDPD-414 Portable (GDPD-414H handheld) Partial Discharge Detector adopts smart quick intelligent power test system (Soft No. 1010215, trademark registration number 14684781 (14684481)). It can flexibly configure various sensors according to different products to be tested. TEV, ultrasonic and HFCT are suitable for partial discharge detection of high-voltage switchgear and ring network cabinet; Ultrasonic and UHF are suitable for detecting G...