GDP-8000CM SF6 Gas Dew Point Tester (Chilled Mirror Method)

GDP-8000CM SF6 Gas Dew Point Tester (Chilled Mirror Method)

Brief Description:

GDP-8000CM Portable Chilled Mirror SF6 Gas Dew Point Tester is specially designed for SF6 gas micro moisture detection used in the whole temperature zone of the power industry, which is based on Stryn refrigeration and chilled mirror measuring principle.


Product Detail

Product Tags

General Information

GDP-8000CM Portable Chilled Mirror SF6 Gas Dew Point Tester is specially designed for SF6 gas micro moisture detection used in the whole temperature zone of the power industry, which is based on Stryn refrigeration and chilled mirror measuring principle.

It not only solved the problem that Peltier's refrigeration principle mirror surface dew point tester could not be used in the high temperature field, but also solved the problem that the test data of the resistive and capacitive moisture meter can not be stable, the test speed is slow, and the measurement data is inaccurate. The moisture content of SF6 gas can be detected at a temperature of less than 60ºC in the environment with the accuracy of dew point ±0.2ºC.

This product has fast test speed, stable performance and good repeatability. It is suitable for micro moisture detection of SF6 new gas, regeneration gas, running gas and fault gas in power industry.

Application

● Moisture monitoring of SF6 gas electrical equipment for electric power.
● SF6 gas cylinder gas quality test 
● High purity gas manufacturing 
● Semiconductor industry dry gas supply
● Research and development use
● Clean room/dry house monitoring  
● Metal heat treatment site and laboratory industrial gas humidity detection, such as air, CO2, N2, H2, O2, SF6, He, Ar and other inert gases.

Features

● Better than ±2℃ measurement accuracy. 
● The whole channel polymer material design, ensures no water wall hanging phenomenon and guarantees the test speed. 
● The oil-free stainless steel body regulating valve is used to ensure the accuracy of the measured value. 
● Advanced software algorithms improve the test accuracy of sensors. 
● Combined chassis configuration solution, users can easily combine related instruments and accessories. The overall package is carried, which makes the user have a more relaxed experience. 
● Start up test, no need to preheat and oscillate. 
● Temperature conversion and pressure data correction. 
● Fuzzy computing technology. 
● High-power lithium battery power, realize AC and DC dual power supply. No on-site AC power is required. Lithium battery power supply continues to work for more than 8 hours without the need of an external power supply. 
● Anti-electromagnetic interference circuit design to ensure product reliability. 
● It can expand USB communication, serial communication, wireless communication module, and realize the communication and printing functions of the upper computer. 
● Large-capacity memory, which can realize 1000 sets of data storage functions. 
● The gas path pretreatment function can be used to purify the test pipeline before the field test work, which shortens the test time. (optional) 
● The instrument has a test gas recovery function to recover the sulfur hexafluoride measurement gas. 
● The test data is stable and can provide both standard dew point values and converted dew point values at 20℃. 
● The best test flow area shows that the user can adjust the gas flow intuitively and quickly. Reduce test time. 
● The air inlet is designed with a miniature self-sealing joint, and the air path to be tested will not leak when the air path is disconnected.

Specification
Measurement method Chilled Mirror Method
Measurement range dew point -110℃--+20℃(support ppmv)
Accuracy ±2℃ (when the dew point temperature is below 0 ℃, the sensor output is the frost point)
Response time 63% [90%]
+20→-20℃ Td 5s[45s]
-20→-60℃ Td 10s[240s]
Resolution 0.01℃
Repeatability  ± 2 ℃
Display unit ℃, ppm, ℃P20(converted value at 20℃)
Gas flow 400-600ml/min
Flow display 0-1000mL digital flowmeter
Sample gas pressure ≤1MPa
Power supply 220VAC±10%, 50Hz, AC/DC use, over-charge protection, continuous working is no lower than 8hours.
Use environment temperature -20--+60℃
Environment humidity 90%RH
Measurement value influence No affect of pressure and flow
Dimension 395*295*155mm
Weight about 2kg

  • Previous:
  • Next:

  • Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us