MRT-15 15kV Insulation Resistance Tester | High Voltage Megohmmeter with IR/PI/DAR/DD/SV Testing
• Digital processing technology, with strong anti-interference ability, suitable for measuring in strong electromagnetic interference environment.
• Large capacity, meets the requirements of high voltage, high resistance, large capacity load test.
• With shockproof, moisture-proof and dust-proof structure, adapt to the harsh working environment.
• User friendly, display accurate results and data change trends.
• Perfect protection function, able to withstand impact of short circuit and residual voltage of the measured capacitance.
• Output high voltage of each range can be continuously adjusted from zero.
• Automatic measurement of R15, R60, R600, automatic calculation of absorption ratio and polarization index.
• Maximum resistance measurement range up to 10TΩ, automatic switching range.
• Automatic measurement of ambient temperature, air humidity and test time.
• Displays the test time, buzz tips at every 15 seconds, 5 minutes without operation will prompt shutdown.
• Automatically discharge high voltage after measurement is completed, the discharge time is not more than 30 seconds.
• Storage of 60 groups of measuring results, and the data will not be lost for 20 years.
•With RS232 serial interface, able to communicate with computer.
•Display voltage of live test object before test.
• Automatically stop testing as per preset test time.
• Able to detect leakage current Ix and absorption capacitance Cx.
|
Function |
Parameters |
|||||||
|
Max. Output Voltage |
15kV |
|||||||
|
Voltage steps |
500V, 1.0kV, 2.0kV, 2.5kV, 5.0kV, 10.0kV ,15.0kV |
|||||||
|
High voltage display error |
±5% |
|||||||
|
Resistance range |
Upper limit |
100GΩ-10TΩ |
||||||
|
Lower limit |
0.1MΩ |
|||||||
|
Accuracy class |
5.0 class |
|||||||
|
High voltage display error |
±( 5%•Ux+1d ) |
|||||||
|
Leakage current display range & error |
±0.5℃ |
|||||||
|
Absorption capacitance display range & error |
0.1nA~9.9mA, 5% |
|||||||
|
High voltage display error |
0.1pF~99μF, 5% |
|||||||
|
Humidity measuring error |
±2%RH |
|||||||
|
Short circuit current |
Approx. 6mA |
|||||||
|
Voltage ripple |
<3% |
|||||||
|
Insulation resistance |
> 500MΩ (between test wire and case) |
|||||||
|
Withstand voltage |
AC10.0kV 50Hz 1min (between test wire and case) |
|||||||
|
Power supply |
12V lithium battery |
|||||||
|
Battery service time after one charging |
30 days. 10 times DAR & 5 times PI test per day |
|||||||
|
Working temperature and humidity |
0℃ ~ + 40℃; < 85%RH |
|||||||
|
Storage temperature and humidity |
- 20℃ ~ + 50℃; < 90%RH |
|||||||
|
Resistance measuring error |
||||||||
| Voltage steps |
500 V |
1.0 kV |
2.0 kV |
2.5 kV |
5.0 kV |
10.0 kV |
15.0 kV |
|
|
± (3%·Rx + 1d ) |
5GΩ |
5GΩ |
10GΩ |
10GΩ |
20GΩ |
40GΩ |
60GΩ |
|
|
± (5%·Rx + 1d ) |
40GΩ |
80GΩ |
160GΩ |
200GΩ |
200GΩ |
200GΩ |
500GΩ |
|
|
± (10%·Rx + 2d ) |
200GΩ |
400GΩ |
800GΩ |
1TΩ |
1TΩ |
1TΩ |
1TΩ |
|
|
± (25%·Rx + 2d ) |
1TΩ |
2TΩ |
2TΩ |
2TΩ |
2TΩ |
2TΩ |
2TΩ |
|