OEM Best 4000 Amps Primary Injection Test Kit Online Sale Manufacturer – GDHL-100B Contact Resistance Tester (Microhm Meter) – HV Hipot
OEM Best 4000 Amps Primary Injection Test Kit Online Sale Manufacturer – GDHL-100B Contact Resistance Tester (Microhm Meter) – HV Hipot Detail:
Description
The performance of the conductive circuit of the circuit breaker is important to ensure the safe operation of the switch. The pros and cons of the conductive performance can be reflected by the size of the resistance of the conductive loop. Therefore, the IEC standard and the manufacturer have stipulated that the loop resistance should be measured, and there are clear specifications for the loop resistance of various types of switches. The loop resistance tester is a testing instrument meets the requirements of GB50150-2006 and DL / T 845.4-2004 regulations. It is widely applicable to the measurement of contact resistance, loop resistance, cable, wire, and weld contact resistance of various electrical switches.
Application
● High,middle and low voltage circuit breakers
● High,middle and low voltage disconnecting switches
● High-current bus bar joints
● Cable & Welding joints
It is suitable for high current, micro ohm measuremen
Features

Specifications
| Power supply | AC220V±10%, 50Hz |
| Power consumption | ≤500W |
| Working mode | Output time can be set. |
| Test current | 50A, 100A |
| Measurement range | 1-1999.9μΩ, resolution 0.01μΩ |
| Accuracy | 1%±0.5μΩ |
| Constant source output voltage | ≤ 5V |
| Working temperature | -20℃~40℃ |
| Relative humidity | ≤ 80%RH (no condensate) |
| Weight | 5kg |
Accessories
| Contact resistance tester | 1 set |
| Test lead | 2 pieces |
| Power cord | 2 piece |
| Fuse | 2 pieces |
| Printer paper | 2 rolls |
| Standard resistor | 1 piece |
| Ground wire | 1 piece |
| User’s manual | 1 copy |
| Test report | 1 copy |
| QC pass | 1 copy |
| Packing list | 1 copy |
Product detail pictures:
Related Product Guide:
Well-run products, skilled income group, and better after-sales products and services; We have been also a unified massive family, all people stick with the business price "unification, dedication, tolerance" for OEM Best 4000 Amps Primary Injection Test Kit Online Sale Manufacturer – GDHL-100B Contact Resistance Tester (Microhm Meter) – HV Hipot , The product will supply to all over the world, such as: Brunei, Cambodia, Greenland, The working experience in the field has helped us forged a strong relations with customers and partners both in domestic and international market. For years, our products and solutions have been exported to more than 15 countries in the world and have been widely used by customers.
Managers are visionary, they have the idea of "mutual benefits, continuous improvement and innovation", we have a pleasant conversation and Cooperation.





