OEM Best Ac Hipot Test Set Factories – DC High Voltage Generator GDZG-300 – HV Hipot
OEM Best Ac Hipot Test Set Factories – DC High Voltage Generator GDZG-300 – HV Hipot Detail:
Features
● Simple operation and complete function, easy for wild work.
● Higher voltage stability, smaller ripple coefficient.
● More reliable and stable, continuous short-circuit discharge directly to ground.
● Intelligent grounding protection and alarm function. High precision, accurate measurement, digital display of voltmeter and ammeter, with voltage resolution 0.1kV, and current 0.1uA.
● High stability of voltage regulation, smooth voltage boosting process, high adjustable precision, with coarse and fine adjustment functions. Accuracy of voltage regulation better than 0.1%, voltage and current measurement error is less than 1.0%, ripple factor better than 0.5%.
● With function of high-accuracy 75%VDC-1mA, more convenient for zinc oxide lighting arrester DC testing.
● HV booster is small size and large capacity, with △-Y shoring in the packing, which is portable to carry.
Specifications
|
Rated voltage |
40kV/60kV/120kV/200kV/300kV/500kV |
|
Rated current |
2mA/3m A/4mA/5mA/10mA |
|
Power supply |
AC 220V±10%, 50Hz |
|
Ripple coefficient |
≤1.0% |
|
Voltage meter precision |
± (1.0 %reading±2 digit) |
|
Current meter precision |
± (1.0 %reading±2 digit) |
|
Voltage stabilization |
Stochastic wave, ≤1% when power wave±10% |
|
Environment temperature |
-10 ~ 40℃ |
|
Relative humidity |
≤85% (no condensate) |
Product detail pictures:
Related Product Guide:
We keep on with our enterprise spirit of "Quality, Efficiency, Innovation and Integrity". We intention to create extra worth for our buyers with our prosperous resources, superior machinery, experienced workers and superb services for OEM Best Ac Hipot Test Set Factories – DC High Voltage Generator GDZG-300 – HV Hipot , The product will supply to all over the world, such as: Norwegian, US, Suriname, We only supply quality items and we believe this is the only way to keep business continue. We can supply custom service too such as Logo, custom size, or custom merchandise etc that can according to customer's requirement.
In China, we have purchased many times, this time is the most successful and most satisfactory, a sincere and realiable Chinese manufacturer!





