OEM Best Battery Regenerator Manufacturers – GDKH-10 Battery Activator – HV Hipot
OEM Best Battery Regenerator Manufacturers – GDKH-10 Battery Activator – HV Hipot Detail:
General Information
In all operating equipment and operating network systems with increasing informationization and automation, uninterrupted power supply is the most basic guarantee. Whether it is AC or DC uninterruptible power supply system, the battery acts as backup power source plays an important role in power source system. Usually, the battery is in the state of floating charge standby. Once the AC power is lost or other accidents, the battery becomes the sole energy supplier of the load.
We know that in addition to the normal life cycle of the battery, some of the early failure of the battery may occur due to problems such as the quality of the battery itself, defects in materials, structures, processes, and improper use. In order to verify the standby time and actual capacity of the battery pack and ensure the normal operation of the system, it is necessary to perform a verification test of the capacity of the battery pack on a regular or as needed basis to detect individual failures at an early stage. Replace the failed single cells to ensure the effectiveness of the entire battery; or to assess the life expectancy of the entire battery.
Features
● Using high-power winding resistance, the discharge current is more stable and fast.
● There is a USB interface, which can transfer the data of the charging and discharging process to the U disk and import it into the PC. PC data management software analyzes the process of battery discharge and generates corresponding data reports. Make data transfer more convenient.
● It adopts intelligent single-chip ARM control and 7-inch touch LCD for Chinese and English display. The menu operation is simple and straightforward.
● The automatic protection function automatically sets the charge and discharge time to, the charge and discharge capacity, the battery voltage is lower than the set minimum protection voltage, the load connection line is abnormal, and automatically stops discharging and alarms, and automatically records the stop mode.
● A variety of charge and discharge termination conditions, including battery termination voltage, discharge capacity, discharge time, to ensure the safety of the discharge test.
● Up to 10 automatic discharge-charge cycles can be set
Specifications
|
Output voltage |
1.5~16V |
|
Output current |
2V battery: 0~100A; 4/6V battery: 0 ~60A; 12V battery: 0~30A |
|
Single cell voltage resolution |
2V: 0.001V; 6V/12V: 0.001V |
|
Working mode |
Single machine use, constant current mode |
|
Protection performance |
Over voltage protection: LCD prompt; Over current protection: LCD prompts; 65°C overheat protection: LCD prompt, buzzer alarm; |
|
Voltage test accuracy |
0.5% |
|
Current test accuracy |
1% |
|
Current control accuracy |
0.1A |
|
Data storage capacity |
2Gbit FLASH |
|
Heat transfer |
Forced air cooling |
|
Temperature |
Working range: -5~50°C Storage temperature: -40~70°C |
|
Humidity |
Relative humidity 0~90% (40±2°C) |
|
Altitude |
4000 meters |
|
Noise |
<60dB |
|
Voltage |
Single-phase three-wire system 220V AC (–20% to +30%), frequency: 45 to 65Hz; |
|
Withstand voltage test |
Input – Case: 2200Vdc 1min Input-output: 2200Vdc 1min Output – Case:700Vdc 1min |
|
Safety |
Meet EN610950 |
|
AC input |
public socket for 1~1.5mm2 cable |
|
DC output |
25mm2 cable quick connector (red positive black negative) |
Product detail pictures:
Related Product Guide:
We insist on offering premium quality manufacturing with superior business concept, honest product sales as well as finest and fast assistance. it will bring you not only the good quality product or service and huge profit, but the most significant is to occupy the endless market for OEM Best Battery Regenerator Manufacturers – GDKH-10 Battery Activator – HV Hipot , The product will supply to all over the world, such as: Cannes, Zimbabwe, Salt Lake City, Our products are widely recognized and trusted by users and can meet continuously changing economic and social needs. We welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!