OEM Best Capacitance And Dissipation Factor Test Supplier – Partial Discharge Test System GDYT series – HV Hipot
OEM Best Capacitance And Dissipation Factor Test Supplier – Partial Discharge Test System GDYT series – HV Hipot Detail:
GIT Series GIS High Voltage Test Sets integrate the high voltage boosting, high voltage measurement, high voltage transformer, high voltage coupling capacitors and all components in a sealed space.
There are two modes to generate high voltage
1) Using reactor inductance and test object capacitance to realize voltage resonance test, to obtain a high voltage, high current from test object.
2) The other one is to obtain required high voltage directly from high voltage transformer.
It is widely used for high voltage, big capacity GIS power equipment insulated withstand voltage test, partial discharge test and GIS transformer accuracy test, suitable for GIS substation, GIS power equipment manufacturer, basin type electrical insulator manufacturer.


Features
● The High voltage obtained are well sealed and shielded in containers, protect the safety of person, no outside interference.
● Accurate test measurement.
● If adding a high voltage sleeve interface, it can lead to high voltage, that can do various high voltage test to traditional high voltage equipment.
● The safest type of high voltage test.


Specifications
● Output voltage: 100kV, 200kV, 250kV, 300kV, 500kV, 750kV, 1000kV, based on different test objects.
● Capacity: 50-2000kVA, based on different test objects.
● High voltage generated mode: high voltage transformer voltage boost and series resonance (power frequency, frequency conversion).
● All methods of boost voltage are one level voltage boost, no need to cascade boost voltage.
● Input voltage: 0.35-10kV.
● Partial discharge: Rated voltage 3pc (normal environment).
● Impedance voltage: 5%.
● Temperature rise: no more than 65k (50Hz) when rated current operates 60mins.


Product detail pictures:
Related Product Guide:
Sticking to the perception of "Creating products of top of the range and earning mates with people today from all over the world", we constantly put the desire of consumers in the first place for OEM Best Capacitance And Dissipation Factor Test Supplier – Partial Discharge Test System GDYT series – HV Hipot , The product will supply to all over the world, such as: Uruguay, Johannesburg, Nepal, We only supply quality products and we believe this is the only way to keep business continue. We can supply custom service too such as Logo, custom size, or custom products etc that can according to customer's requirement.