OEM Best Capacitor Discharge Device Factories – Partial Discharge Test System GDYT series – HV Hipot
OEM Best Capacitor Discharge Device Factories – Partial Discharge Test System GDYT series – HV Hipot Detail:
GDYT is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It widely used in electrical manufacturing, power operation departments, research institutes and universities.
It includes below components
1. Hipot Test Control Unit GDYD
2. PD-free Gas type transformer YDQW
3. Coupling capacitor
4. Protective resistor
5. Isolation filter LBQ
6. Partial discharge detector
Features
● Advanced PD-free epoxy insulating tube, small partial discharge capacity.
● Low impedance voltage, better than national standard.
● Automatic control technology, good anti-interference performance.
● Rapid electronic protection, high reliability.
Specifications
● Rated Capacity (KVA) : 5~5500
● High Voltage (KV): 50~250
● Low Voltage (KV): 0.22/0.38~0.38/0.6~0.6/3~3/6/10
● Top cover(mm): accordance with specific conditions
Model | Rated Capacity | High Voltage | Low Voltage | Top cover OD x Height | Weight |
(KVA) | (KV) | (KV) | (mm) | (KG) | |
GDYT-5/50 | 5 | 50 | 0.22/0.38 | 320×450 | 42 |
GDYT-50/50 | 50 | 50 | 0.22/0.38 | 850×945 | 360 |
GDYT-10/100 | 10 | 100 | 0.22/0.38 | 570×725 | 150 |
GDYT-50/100 | 50 | 100 | 0.22/0.38 | 850×1000 | 400 |
GDYT-100/100 | 100 | 100 | 0.22/0.38 | 850×1000 | 800 |
GDYT-15/150 | 15 | 150 | 0.22/0.38 | 1165×1400 | 500 |
GDYT-75/150 | 75 | 150 | 0.22/0.38 | 1350×1570 | 1100 |
GDYT-150/150 | 150 | 150 | 0.38/0.6 | 1350×1570 | 1400 |
GDYT-20/200 | 20 | 200 | 0.22/0.38 | 1165×1850 | 760 |
GDYT-100/200 | 100 | 200 | 0.22/0.38 | 1450×1950 | 1800 |
GDYT-200/200 | 200 | 200 | 0.38/0.6 | 1800×1950 | 3100 |
GDYT-25/250 | 25 | 250 | 0.22/0.38 | 1250×2200 | 1250 |
GDYT-150/250 | 150 | 250 | 0.38/0.6 | 1450×2200 | 1900 |
GDYT-250/250 | 250 | 250 | 0.38/0.6 | 2000×2300 | 3100 |
GDYT-500/250 | 500 | 250 | 3/6 | 200×2600 | 5800 |
GDYT-1000/250 | 1000 | 250 | 3/6 | 2200×2600 | 8200 |
Product detail pictures:
Related Product Guide:
The customer satisfaction is our primary goal. We uphold a consistent level of professionalism, quality, credibility and service for OEM Best Capacitor Discharge Device Factories – Partial Discharge Test System GDYT series – HV Hipot , The product will supply to all over the world, such as: Swansea, Ukraine, Macedonia, We firmly think that we have the full capability to give you contented merchandise. Wish to collect concerns within you and build a new long-term synergy romantic relationship. We all significantly promise:Csame excellent, better selling price; exact selling price, better quality.