OEM Best Current Impulse Generator Manufacturers – GDCY-20B 20kV Impulse Voltage Tester (Basic Type) – HV Hipot Detail:
GDCY-12B Programmable Automatic Impulse Voltage Tester is mainly based on TB/T 2653, GB/T 17627, GB/T 16927, GB14048, GB7251, GB/T 16935, IEC 61730, GB4706, GB3048, JB/T 7083 and other standard requirements. It is mainly used for safety performance (dielectric performance) detection of low-voltage electrical appliances, high and low voltage switches, solar energy, electricity meters, relays, leakage protectors, etc. The impulse output can be controlled by computer, and the test report can be printed and generated.
(Picture only for reference first.)
Features
● Manual/automatic/programmable mode: Manual mode adjusts impulse voltage manually by adjusting knob; Automatic mode adjusts impulse voltage automatically by the system; Programmable mode uses computer to control impulse voltage automatically.
● Automatic mode and programmable mode have automatic constant voltage system, which can control impulse output voltage more precisely and is not affected by interval time.
● Programmable control function provides 485 communication interface and program control protocol. Programmable test system can be set up according to need. Impulse voltage and various parameters (programmable trigger) can be controlled by computer or programmable network.
● Through computer program control software, batch combination testing can be realized, such as 2KV3 times, 4KV3 times, 6KV3 times, -2KV3 times, -4KV3 times, -6KV3 times, etc. The maximum 50 groups of combination testing can be realized, and the test results such as breakdown times and breakdown voltage can be fed back to the computer. The computer can display the feedback results graphically to make the judgment more intuitive.
● The test report can be printed and generated by computer, and the test data such as peak value, number of impulse and interval time can be displayed.
● The function of automatic judgment of test results can automatically judge whether the test is qualified or not according to the magnitude and attenuation degree of impulse current generated during the test.
● Provides a impulse divider interface for the oscilloscope to track the output voltage waveform and monitor the output voltage.
● 128*64 LCD display, showing DC voltage, impulse voltage, interval time, and number of impulse.
● Touch buttons, PC control, English panel and program menu are available.
● Positive and negative polarity is designed by the dual system of positive high voltage source and negative high voltage source. The output is more stable, the voltage is higher and the efficiency is higher.
● Original full-scale calibration process, the full range accuracy is better.
● Built-in multiple parameter standard calibration procedures, the error can be corrected at any time.
● DC and impulse dual output.
Specifications
● Output impulse peak voltage: 20kV (4kV-12kV), accuracy: +3%;
Direct setting of impulse voltage range in automatic mode and programmable mode: 4kV-20kV;
Step Voltage: 1V;
● Impulse voltage waveform: wave front time 1.2μs±30%;
wave half-peak time 50μs±20%;
● Breakdown judgment: leakage current: 30mA-1200mA can be set;
voltage attenuation: 0-99% can be set;
● Interval time: 1-9999S;
● Number of impulse: 1-9999/infinite continuous impulse;
● Polarity: Positive/Negative/Positive and Negative alternately set;
● Dimension: 450mm*380mm*240mm;
● Weight: about 12 kg;
● Optional Extension System Support: WinXP Win7.
Accessory
Impulse Voltage Tester: 1 piece
High and low voltage test cables: 1 set
Communication cable of 485-USB converter: 1 piece
DB9 Serial port extension cable: 1 piece
Basic control system software: 1 set
Product detail pictures:
Related Product Guide:
While in the past few years, our organization absorbed and digested innovative technologies both equally at home and abroad. Meanwhile, our organization staffs a group of experts devoted for the advancement of OEM Best Current Impulse Generator Manufacturers – GDCY-20B 20kV Impulse Voltage Tester (Basic Type) – HV Hipot , The product will supply to all over the world, such as: Czech, Benin, Sweden, We solution have passed through the national skilled certification and been well received in our key industry. Our specialist engineering team will often be ready to serve you for consultation and feedback. We are able to also provide you with no cost samples to meet your needs. Best efforts will be produced to offer you the very best service and solutions. For anyone who is considering our business and solutions, please speak to us by sending us emails or get in touch with us right away. As a way to know our products and enterprise. lot more, you'll be able to come to our factory to find out it. We will constantly welcome guests from around the globe to our firm. o build enterprise. elations with us. Please really feel absolutely free to make contact with us for small business and we believe we will share the top trading practical experience with all our merchants.
By Elsa from Guinea - 2017.11.20 15:58
Problems can be quickly and effectively resolved, it is worth to be trust and working together.
By Modesty from Detroit - 2018.12.25 12:43