OEM Best dew point probe Exporters – GDW-102 Oil Dew Point Tester (Coulometric Karl Fischer Titrator) – HV Hipot
OEM Best dew point probe Exporters – GDW-102 Oil Dew Point Tester (Coulometric Karl Fischer Titrator) – HV Hipot Detail:
Coulometric Karl Fischer technology is applied to measure precisely trace moisture the measured sample contains.The technology is widely used for accuracy and cheap test cost.The Model GDW-102 measure precisely trace moisture on liquid, solid and gas samples according to the technology. It’s used in electricity, petroleum, chemicals, foods and so on.
Features
● Use improved PWM electrolysis circuit to reduce the power dissipation of the instrument.
● High precise measuring electrode signal and circuit detection make the electrolytic end decision quickly and precisely with strong anti-interference ability.
● Use methods of electrolyte blank current compensation and electrolyte balance drift compensation to devise testing result.
● Built in three calculation formula to generate report automatically.
● The buttons regulating mixing speed have ten speeds(0~9speed).
● Measure electrode open-circuit fault and short circuit fault automatically.
● It can store 256 history records with time.
● Calender clock with temperature can automatically store testing date and time accurately, which can work 10 years above with power down.
● When the instrument does not work for long time, the LCD screen will shut down automatically to protect the screen and last the screen life. Press any buttons to quit the screen protection.
● There is RS232 interface to connect with PC and mini-printer easily.
Specification
Electrolysis current |
Max.400mA |
Max electrolysis speed |
Max.2.4mg/min |
Measuring range |
10ug~100mg |
Sensitivity |
0.1ug |
Precision |
±3ug for 10ug~1mg RSD 0.3% or less for 1mg or more |
Ambient Temperature |
5~35℃ |
Ambient humidity |
≤85% RH |
Power Supply |
AC220V±20% 50HZ±10% ,40VA |
Dimensions |
270×210×125(mm) |
Weight |
5kg |
Maximum power consumption |
30W |
Accessories
Main unit | 1 piece |
Electrolysis electrode | 1 piece |
Measurement electrode | 1 piece |
Stirring nut | 2 pcs |
Silica gel particle | 1 piece |
Silica gel mat | 10 pcs |
0.5μl Sample injector | 1 piece |
50μl Sample injector | 1 piece |
1ml Sample injector | 1 piece |
Drying tube | 1 piece |
Power cord | 1 piece |
Vacuum grease | 1 piece |
Electrolyte | 1 piece |
User’s guide | 1 copy |
Factory test report | 1 copy |
Product detail pictures:
Related Product Guide:
We insist on offering high-quality production with great enterprise concept, honest product sales and also the finest and fast service. it will bring you not only the superior quality solution and huge profit, but the most significant should be to occupy the endless market for OEM Best dew point probe Exporters – GDW-102 Oil Dew Point Tester (Coulometric Karl Fischer Titrator) – HV Hipot , The product will supply to all over the world, such as: South Korea, Uruguay, Chile, We warmly welcome your patronage and will serve our clients both at home and abroad with products of superior quality and excellent service geared to the trend of further development as always. We believe you will benefit from our professionalism soon.