General Information
GDBS-305 automatic closed cup flash point tester is the device testing closed cup flash point for petroleum products. It use module design which one host can control several testing furnace, to test different samples at the same time or separately. The testing furnace port can be connected to the host disorderly. It widely used in the field of railway, air company, power, petroleum and research department.
Features
● 320*240 TFT LCD screen.
● With high speed signal processor control, reliable and high accuracy.
● One host can control several test furnace to test several samples at one time, which will save testing time.
● Automatic ignition with no gas source ignition mode.
● Built-in atmosphere pressure sensor, auto-measure and calibrate result.
● Self-adaptive PID control calculation, automatic adjusting temperature rise curve according to standard requirements.
● Procedures including temperature rise,uncap,ignition,alarm,cooling,print are realized automatically.
● With fault auto-detection alarm function.When sensor fault,sample mistake,temperature over value,the instrument will stop automatically and alarm.
● Built-in high speed thermal printer.
● Store up to 255pcs history records.
Specifications and Attentions
● Temperature measure range: -59.9℃–299.9℃
● Temperature control range: room temperature–299.9℃
● Repeatability: 0.025X(X is average value of test result for continuous twice test)
● Resolution: 0.1℃
● Thermometric sensor: Pt resistance(A grade PT100)
● Flash fire sensor: Thermocouple
● Power voltage: AC220V±20% 50HZ±10%
● Max.Power: 400W
● Environmental temperature: 0℃-40℃
● Relative humidity: ≤85% RH
● Weight: 18kg
● Dimension: 480*260*300mm
Product detail pictures:
Related Product Guide:
We normally think and practice corresponding on the change of circumstance, and grow up. We aim at the achievement of a richer mind and body and also the living for OEM Best dew point to relative humidity Supplier – GDBS-305 Automatic Flash Point Closed Cup Tester – HV Hipot , The product will supply to all over the world, such as: Lebanon, Malaysia, Kuwait, Wide selection and fast delivery to suit your needs! Our philosophy: Good quality, great service, keep improving. We've been looking forward that more and more oversea friends join in our family for further development near the future!