OEM Best digital insulation tester Factory – GDCR1000C Non-contact Phase Sequence Tester – HV Hipot
OEM Best digital insulation tester Factory – GDCR1000C Non-contact Phase Sequence Tester – HV Hipot Detail:
General Information
GDCR1000C, GDCR1000D non-contact phase tester is a major breakthrough in traditional phase sequence detection method. The traditional phase sequence detection is to strip the connection pole of three-phase wires, connect three bare clamps or test needles of phase sequence meter to three bare fire lines, while GDCR1000C and GDCR1000D adopt pincers non-contact induction measurement. The phase sequence can be detected by no need peeling off the wire and without touching the bare high-voltage fire wire, just directly clamping three super-inductive high-insulation clamps on the insulation skin of the three-phase fire wire respectively. At the same time, acousto-optic indication of the positive or reverse phase state of the phase sequence of the three-phase power supply can be obtained. There are four strong magnets on the back of the instrument, which can be attached to the distribution box for use.
GDCR1000C, GDCR1000D non-contact phase tester has the functions of looping inspection, simple power inspection, circuit breaking search, breakpoint location, line maintenance and so on.
GDCR1000C, GDCR1000D non-contact phase detector detection is fast, convenient and easy to display at a glance, greatly improving the safety of field testing, effectively protecting the personal safety of operators, and increasing productivity! It is a safety instrument for three-phase power supply phase sequence, motor detection and line maintenance.
GDCR1000C & GDCR1000D:
|
Model |
Test wire outer diameter |
|
GDCR1000C |
ø1.6mm~ø16mm |
|
GDCR1000D |
ø10mm~ø40mm |
Specification
| Function | Phase check(positive phase, reverse phase, missing phase), live line check, breakpoint location , line maintenance |
| Power supply | DC 3V 2 section alkaline dry cell (LR6), continuous use time of about 70 hours |
| Live range | AC 70~1000V, 45~65Hz (sine wave continuous input) |
| Test wire size | Outer diameter ø1.6mm~ø16mm or ø10mm~ø40mm(optional) |
| LED display | [positive phase] 4 phase detection lights turn on clockwise in turn; [reverse phase] 4 phase detection lights turn on clockwise sequentially. [live line] L1, L2 and L3 lights turn on within the range of voltage setting; [missing phase] L1 or L2 or L3 lights are not on. [open circuit] The L1 or L2 or L3 lights are not on. |
| Buzzing | [positive phase] instrument emits intermittent short buzz; [reverse phase] The instrument emits continuous long sounds. |
| Battery Indication | POWER indicator lights up after power on; LOW BATTERY lights up when power is insufficient |
| Magnetism | There are four magnets attached to the back of the instrument, which are attached to the distribution box and can withstand 800g quality. |
| Shut off | After about 5 minutes, the instrument shuts down automatically. |
| Dimension | L 70mm* H 75mm* W30mm |
| Clamp wire length | 0.6m |
| Weight | About 200g (include battery) |
| Working condition | -10℃~55℃;<80%rh |
| Storage condition | -20℃~60℃;<90%rh |
| Measurement max. voltage | AC 1000V |
| Dielectric strength | 5.4kV rms |
| Max. rated power | 300mVA |
| Standards | EN61010-1:2001, EN61010-031:2002, pollution class 2, CAT Ⅲ(600V), transient overvoltage 6000V |
Accessories
| Carry case | 1pc |
| Battery (LR6) | 2pcs |
| Packing list | 1copy |
| User’s Guide | 1copy |
| Factory test report | 1copy |
Product detail pictures:
Related Product Guide:
"Quality initial, Honesty as base, Sincere support and mutual profit" is our idea, so as to build repeatedly and pursue the excellence for OEM Best digital insulation tester Factory – GDCR1000C Non-contact Phase Sequence Tester – HV Hipot , The product will supply to all over the world, such as: Plymouth, Cancun, Poland, We have customers from more than 20 countries and our reputation has been recognized by our esteemed customers. Never-ending improvement and striving for 0% deficiency are our two main quality policies. Should you need anything, don't hesitate to contact us.