OEM Best Electric Capacitor Factories – AC DC High Voltage Divider – HV Hipot
OEM Best Electric Capacitor Factories – AC DC High Voltage Divider – HV Hipot Detail:
GDFR-C1 series AC/DC Voltage Meter
GDFR-C1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. It consists of voltage divider and measurement instrument.
Features
● Balance type equal potential shield structure.
● Fully-sealed insulation cylinder with internal excellent components.
● High accuracy and linearity, good stability and anti-interference ability.
● The voltage ratio can be customized, suitable for calibration.
● Upside down is forbidden when installation.
Technical Specifications
| Model No. | GDFR-C1-50 | GDFR-C1-100 | GDFR-C1-150 | GDFR-C1-200 | GDFR-C1-300 | GDFR-C1-400 |
| Voltage(kV) | 50 | 100 | 150 | 200 | 300 | 400 |
| DC frequency (Hz) | <2 | |||||
| AC frequency (Hz) | 30-300 | |||||
| Accuracy | AC: 1.5%/DC: 1.0% | |||||
| Accuracy for option (G type) | AC: 1.0%/DC: 0.5% | – | ||||
| Accuracy for option (H type) | AC: 0.5%/DC: 0.5% | – | – | |||
| Impedance (MΩ) |
650 | 1280 | 2000 | 2640 | 4000 | 5360 |
| Capacitance (pF) |
320 | 250 | 400 / 160 | 300 | 200 | 300 |
| Voltage ratio | 1000:1 or 10000:1(or customized) | |||||
| Dimension (mm) |
150×150 | 160×160 | 350×350 | 800×800 | 1000×1000 | |
| Cable impedance(Ω) | 50 / 75 | |||||
| Range | 1. Low range: 0-20kV 2. High range: 20kV-rated voltage 3. Low range: 0-200kV 4. High range:200kV-rated voltage |
|||||
| Cable length(m) | 3 | 4 | 6 | 6 | 10 | 10 |
| Weight(kg) | 5.5 | 9.5 | 12.5 | 14.5 | 27 | 40 |
| Packing Medium | Polyurethane foaming agent | |||||
| Operation temperature | 0℃-45℃ | |||||
| Relative humidity | <85%RH, no condensation | |||||
| Altitude | <1500m (or customized) | |||||
| Use condition | Indoor use or outdoor use in Sunny day | |||||
Product detail pictures:
Related Product Guide:
The client satisfaction is our primary concentrate on. We uphold a consistent level of professionalism, top quality, credibility and service for OEM Best Electric Capacitor Factories – AC DC High Voltage Divider – HV Hipot , The product will supply to all over the world, such as: Nigeria, Montreal, Greenland, Furthermore, all of our items are manufactured with advanced equipment and strict QC procedures in order to ensure high quality. If you are interested in any of our goods, please don't hesitate to contact us. We will do our best to meet your needs.
We have been appreciated the Chinese manufacturing, this time also did not let us disappoint,good job!
Send your message to us: