OEM Best Gas Monitor Manufacturer – GDWG-IV SF6 Gas Leak Detector(IR series) – HV Hipot
OEM Best Gas Monitor Manufacturer – GDWG-IV SF6 Gas Leak Detector(IR series) – HV Hipot Detail:
Product Description
GDWG-IV SF6 Gas Leak Detector is infrared red type leak detector(NDIR technology). It is color OLED display and real-time shows SF6 concentration. It rapidly detect SF6 breaker, GIS leakage point and yearly leakage rate qualitatively and quantitatively. It’s a good device suitable for power supply department, installation and overhaul unit, power test institute.
Application
● High Voltage Switch Equipment
● Rotor vane of helicopter
● Gas transmission system
● To detect fire extinguisher
● Ventilation efficiency research of Buildings
● To detect danger
Advantages
● No radiation.
● No need to replace high pressure high pure argon gas regularly.
● No need to approach high pressure gas.
● No need to replace sensors regularly, cost-effective.
● Stable performance, low maintenance cost. No need to make linear calibration every year.
● No affect by moisture and environment pollution.
● High sensitivity, up to 0.01ppmv.
● When serious leakage or the SF6 gas concentration is up to 100%, it will not be polluted or damaged.
Features
● OLED display.
● Built-in Lithium battery.
● User-defined alarm with sound and light.
● High sensitivity and good stability.
● Fast measurement speed, time is up to 3s.
● Temperature and pressure compensation.
● Only response for SF6 gas, not for other gas.
● Small size, easy to carry, suitable for on-site working.
● With gasbag non-slip straps, more comfortable to carry.
● Data storage up to 8000groups.
● Super-light aluminum with full shielding shell.
● External package uses engineering plastic, with water-proof, dust-proof.
Specifications
● Measuring principle: Non-dispersive infrared sensor (NDIR)
● Measuring range: 0-5000ppm SF6
● Accuracy: ±2%FS(0-1000ppm)
● Repeatability error: ≤±1%
● Sensitivity: 0.01ppmv
● Response time: ≤3s
● Recovery time: ≤5s
● Stability: ≤±20ppm, more than 1000hours
● Zero shift: ≤±1%(F.S/year)
● Linear error: ≤±1%
● Storage temperature: -20~+60℃
● Operation temperature: -20~+50℃
● Sampling mode: Built-in electromagnetic diaphragm pump, automatic slot-in type, flow up to 1L/min.
● Working voltage: 220VAC±10%,50Hz Or Built-in Li-battery.
● Dimension: 140×235×83mm
● Weight: about 1.5kg
Accessories
CT/PT Tester | 1piece |
Test Lead | 1set |
Earth cable | 1piece |
Power cord | 1piece |
2A fuse | 2pcs |
User’s guide | 1copy |
Factory test report | 1copy |
Product detail pictures:
Related Product Guide:
we can easily offer you high-quality products and solutions, competitive rate and very best shopper support. Our destination is "You come here with difficulty and we give you a smile to take away" for OEM Best Gas Monitor Manufacturer – GDWG-IV SF6 Gas Leak Detector(IR series) – HV Hipot , The product will supply to all over the world, such as: Costa rica, Sheffield, Gabon, We always insist on the management tenet of "Quality is first, Technology is basis, Honesty and Innovation".We are able to develop new products continuously to a higher level to satisfy different needs of customers.
By Margaret from Australia - 2018.09.29 17:23
The goods are very perfect and the company sales manager is warmful, we will come to this company to purchase next time.
By Gladys from Angola - 2018.11.11 19:52