OEM Best Handheld Gas Leak Detector Factories – GDWG-IV SF6 Gas Leak Detector(IR series) – HV Hipot
OEM Best Handheld Gas Leak Detector Factories – GDWG-IV SF6 Gas Leak Detector(IR series) – HV Hipot Detail:


Product Description
GDWG-IV SF6 Gas Leak Detector is infrared red type leak detector(NDIR technology). It is color OLED display and real-time shows SF6 concentration. It rapidly detect SF6 breaker, GIS leakage point and yearly leakage rate qualitatively and quantitatively. It’s a good device suitable for power supply department, installation and overhaul unit, power test institute.
Application
● High Voltage Switch Equipment
● Rotor vane of helicopter
● Gas transmission system
● To detect fire extinguisher
● Ventilation efficiency research of Buildings
● To detect danger
Advantages
● No radiation.
● No need to replace high pressure high pure argon gas regularly.
● No need to approach high pressure gas.
● No need to replace sensors regularly, cost-effective.
● Stable performance, low maintenance cost. No need to make linear calibration every year.
● No affect by moisture and environment pollution.
● High sensitivity, up to 0.01ppmv.
● When serious leakage or the SF6 gas concentration is up to 100%, it will not be polluted or damaged.
Features
● OLED display.
● Built-in Lithium battery.
● User-defined alarm with sound and light.
● High sensitivity and good stability.
● Fast measurement speed, time is up to 3s.
● Temperature and pressure compensation.
● Only response for SF6 gas, not for other gas.
● Small size, easy to carry, suitable for on-site working.
● With gasbag non-slip straps, more comfortable to carry.
● Data storage up to 8000groups.
● Super-light aluminum with full shielding shell.
● External package uses engineering plastic, with water-proof, dust-proof.
Specifications
● Measuring principle: Non-dispersive infrared sensor (NDIR)
● Measuring range: 0-5000ppm SF6
● Accuracy: ±2%FS(0-1000ppm)
● Repeatability error: ≤±1%
● Sensitivity: 0.01ppmv
● Response time: ≤3s
● Recovery time: ≤5s
● Stability: ≤±20ppm, more than 1000hours
● Zero shift: ≤±1%(F.S/year)
● Linear error: ≤±1%
● Storage temperature: -20~+60℃
● Operation temperature: -20~+50℃
● Sampling mode: Built-in electromagnetic diaphragm pump, automatic slot-in type, flow up to 1L/min.
● Working voltage: 220VAC±10%,50Hz Or Built-in Li-battery.
● Dimension: 140×235×83mm
● Weight: about 1.5kg
Accessories
| CT/PT Tester | 1piece |
| Test Lead | 1set |
| Earth cable | 1piece |
| Power cord | 1piece |
| 2A fuse | 2pcs |
| User’s guide | 1copy |
| Factory test report | 1copy |

Product detail pictures:
Related Product Guide:
We thinks what clients think, the urgency of urgency to act from the interests of a purchaser position of principle, allowing for greater top quality, decrease processing costs, price ranges are much more reasonable, won the new and aged prospects the support and affirmation for OEM Best Handheld Gas Leak Detector Factories – GDWG-IV SF6 Gas Leak Detector(IR series) – HV Hipot , The product will supply to all over the world, such as: New Zealand, Croatia, Belarus, Due to our good products and services, we have received good reputation and credibility from local and international customers. If you need more information and are interested in any of our products, please feel free to contact us. We look forward to becoming your supplier in the near future.
Reasonable price, good attitude of consultation, finally we achieve a win-win situation,a happy cooperation!




