Features
● Complete equipment and wide voltage levels in the whole set of device.
● Small electric inductance in the return circuit of the impulse voltage generator, A band-stop filtering is adopted so that a standard impulse wave is still generated even under a large capacity load, and large load capacity.
● Large in voltage utilization coefficient.
● Convenient in wave adjustment, simple in operation, excellent in synchronization performance and reliable in motion.
● An automatic control technique is adopted in the constant-current charge, which is high automation and strong anti-interference capacity.
● A digital measurement and analysis system for the impulse test date are adopted, which increase the technical level and the efficiency of the impulse voltage tests.
Specifications
Impulse voltage grade | 100kV-7200kV |
Standard lightning wave | 1.2±30%/50±20%µS |
Peak oscillation | <5% |
Standard switching wave | 250±20%/2500±60%µS |
Virtual front time of oscillating lightning wave | ≤15µS |
Virtual front time of oscillating switching wave and virtual front time of oscillating switching impulse wave |
15µS-1mS |
The minimum output voltage | ≥10%Un |
Charging voltage instability | <±1% |
Synchronizing range | ≥20% |
Synchronous discharge error rate | <2% |
Ignition range | 10%~100% |
Working time | ≥70%UN Discontinuous work (charge-discharge 300s/time) <70%nn Continuous work (charge-discharge 120s/time) |
Generator efficiency: lightning wave (no load) | ≥90% |
Time to chopping | 2~5µS |
Product detail pictures:
Related Product Guide:
abide by the contract", conforms towards the market requirement, joins during the market competition by its good quality likewise as provides additional comprehensive and great services for customers to let them turn out to be big winner. The pursue of your enterprise, is the clients' fulfillment for OEM Best High Voltage Instruments Manufacturer – Impulse Voltage Test System – HV Hipot , The product will supply to all over the world, such as: United Kingdom, French, Danish, We are confident that we are able to provide you with opportunities and will be a valuable business partner of you. We look forward to working with you soon. Learn more about the types of products that we work with or contact us now directly with your inquiries. You are welcome to contact us anytime!