OEM Best High Voltage Laboratory Equipment Factories – Impulse Voltage Test System – HV Hipot
OEM Best High Voltage Laboratory Equipment Factories – Impulse Voltage Test System – HV Hipot Detail:
Features
● Complete equipment and wide voltage levels in the whole set of device.
● Small electric inductance in the return circuit of the impulse voltage generator, A band-stop filtering is adopted so that a standard impulse wave is still generated even under a large capacity load, and large load capacity.
● Large in voltage utilization coefficient.
● Convenient in wave adjustment, simple in operation, excellent in synchronization performance and reliable in motion.
● An automatic control technique is adopted in the constant-current charge, which is high automation and strong anti-interference capacity.
● A digital measurement and analysis system for the impulse test date are adopted, which increase the technical level and the efficiency of the impulse voltage tests.
Specifications
| Impulse voltage grade | 100kV-7200kV |
| Standard lightning wave | 1.2±30%/50±20%µS |
| Peak oscillation | <5% |
| Standard switching wave | 250±20%/2500±60%µS |
| Virtual front time of oscillating lightning wave | ≤15µS |
| Virtual front time of oscillating switching wave and virtual front time of oscillating switching impulse wave |
15µS-1mS |
| The minimum output voltage | ≥10%Un |
| Charging voltage instability | <±1% |
| Synchronizing range | ≥20% |
| Synchronous discharge error rate | <2% |
| Ignition range | 10%~100% |
| Working time | ≥70%UN Discontinuous work (charge-discharge 300s/time) <70%nn Continuous work (charge-discharge 120s/time) |
| Generator efficiency: lightning wave (no load) | ≥90% |
| Time to chopping | 2~5µS |
Product detail pictures:
Related Product Guide:
We pursue the administration tenet of "Quality is remarkable, Services is supreme, Status is first", and will sincerely create and share success with all customers for OEM Best High Voltage Laboratory Equipment Factories – Impulse Voltage Test System – HV Hipot , The product will supply to all over the world, such as: Iceland, Greek, Puerto Rico, Our staffs are adhering to the "Integrity-based and Interactive Development" spirit, and the tenet of "First-class Quality with Excellent Service". According to the needs of every customer, we provide customized & personalized services to help customers achieve their goals successfully. Welcome clients from home and abroad to call and inquire!
High production efficiency and good product quality, fast delivery and completed after-sale protection, a right choice, a best choice.