Brief Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our mission will be to grow to be an innovative supplier of high-tech digital and communication devices by giving worth added design and style, world-class production, and service capabilities for Voltage Pulse Generator, Capacitor Unit Of Measure, Gis Online Pd System, We are going to wholeheartedly welcome all clientele during the industry both of those at your home and overseas to cooperate hand in hand, and build a bright potential together.
OEM Best How To Test Circuit Breaker Manufacturers – GMDL-02A HV Circuit Breaker Analog Device – HV Hipot Detail:

General Information

GMDL-02A high-voltage circuit breaker simulation device is manufactured using the principles of large-scale field programmable gate arrays, power electronic devices with protection, etc.

The open coil is designed according to an independent loop, which can simulate the three-phase and split-phase operation of the voltage level of 6-110KV. The action behavior of the single open coil circuit breaker is suitable for the selection of power systems, industrial and mining enterprises, scientific research institutes, professional colleges, and protection manufacturers.

It is used as a substitute for actual circuit breakers in the transmission test of the entire system of relay protection and automatic devices with switches.

The action is accurate, reliable, and the number of actions is not limited, which can greatly improve the accuracy and completeness of the test, minimize the number of actions of the actual circuit breaker, and increase the service life. It is an important supporting equipment for the relay protection test work.

Features

Working power supply voltage: AC220V±10% 50HZ working current is less than 0.5A
open and closing operating voltage: DC200V or DC110V.
open and closing time open time selection: Closing time selection:
20ms, 30ms, 40 ms, 50 ms, 60 ms, 70 ms, 90 ms, 110 ms, the error does not exceed ±5ms 40 ms, 60 ms, 80 ms, 100 ms, 200 ms, 300 ms, 400 ms, 500 ms, the error does not exceed ±5ms, (when 500ms, the error does not exceed ±20ms).

open and closing current open resistor selection: ∞Ω, 100Ω, 200Ω, 400Ω
Closing resistance selection: ∞Ω, 100Ω, 200Ω, 400Ω
The opening and closing current is automatically cut off by the time of opening and closing.
Manual opening and closing When the high-voltage circuit breaker simulation device is operated through the “manual close” and “manual open” buttons on the panel, the high-voltage circuit breaker simulation device is opened, and no current flows in the closing coil.
Breaker failure When the circuit breaker failure button is pressed, the circuit breaker does not operate, the opening and closing currents are delayed after 1s and then disconnected, and the current state is restored after another 20s.
Draw out Draw out:
DC220V/0.5A, AC220V/5A.
Circuit breaker position output contact: 12 pairs of circuit breaker position output contacts, independent of each other.  Divided into two groups, corresponding to the circuit breaker open coil.
Hand close, hand jump contact: The hand-close and hand-jump buttons each have a pair of synchronous output normally open contacts. When the hand close and hand jump buttons are pressed, the contact is connected. Among them, the hand-closed contact is self-maintained after the action, and reset by the hand-jump button. When the hand-jump button is released, the hand-jump contact will return with a delay of 60ms.

Product detail pictures:

OEM Best How To Test Circuit Breaker Manufacturers –  GMDL-02A HV Circuit Breaker Analog Device – HV Hipot detail pictures

OEM Best How To Test Circuit Breaker Manufacturers –  GMDL-02A HV Circuit Breaker Analog Device – HV Hipot detail pictures

OEM Best How To Test Circuit Breaker Manufacturers –  GMDL-02A HV Circuit Breaker Analog Device – HV Hipot detail pictures

OEM Best How To Test Circuit Breaker Manufacturers –  GMDL-02A HV Circuit Breaker Analog Device – HV Hipot detail pictures


Related Product Guide:

We're going to dedicate ourselves to offering our esteemed shoppers with the most enthusiastically considerate solutions for OEM Best How To Test Circuit Breaker Manufacturers – GMDL-02A HV Circuit Breaker Analog Device – HV Hipot , The product will supply to all over the world, such as: Juventus, Grenada, Philippines, The company has perfect management system and after-sales service system. We devote ourselves to building a pioneer in the filter industry. Our factory is willing to cooperate with different customers domestic and overseas to gain better and better future.
  • The factory has advanced equipment, experienced staffs and good management level, so product quality had assurance, this cooperation is very relaxed and happy!
    5 Stars By Chris from Auckland - 2018.09.19 18:37
    This is a very professional and honest Chinese supplier, from now on we fell in love with the Chinese manufacturing.
    5 Stars By Gail from Oslo - 2017.04.28 15:45

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us