OEM Best Infrared Gas Detector Factory – GDWG-V SF6 Gas Leak Detector (IR type, Double display) – HV Hipot
OEM Best Infrared Gas Detector Factory – GDWG-V SF6 Gas Leak Detector (IR type, Double display) – HV Hipot Detail:


Product Description
GDWG-V SF6 Gas Leak Detector is infrared red type leak detector (NDIR technology) with double display. It is color INCELL TFT display and real-time shows SF6 concentration. It rapidly detects SF6 breaker, GIS leakage point and yearly leakage rate qualitatively and quantitatively. It is a good device suitable for power supply department, installation and overhaul unit, power test institute.
Application
● High Voltage Switch Equipment
● Rotor vane of helicopter
● Gas transmission system
● To detect fire extinguisher
● Ventilation efficiency research of Buildings
● To detect danger
Advantages
● No radiation.
● No need to replace high pressure high pure argon gas regularly.
● No need to approach high pressure gas.
● No need to replace sensors regularly, cost-effective.
● Stable performance, low maintenance cost. No need to make linear calibration every year.
● No affect by moisture and environment pollution.
● High sensitivity, up to 0.01ppmv.
● When serious leakage or the SF6 gas concentration is up to 100%, it will not be polluted or damaged.
Features
● Color TFT In-Cell screen, double display, visual in sunlight.
● Built-in Lithium battery.
● User-defined alarm with sound and light.
● High sensitivity and good stability.
● Fast measurement speed, time is up to 3s.
● Temperature and pressure compensation.
● Only response for SF6 gas, not for other gas.
● Non-gas contact measurement features ensure that no sensor poisoning will occur at any concentration.
● The sensor constant temperature chamber can ensure that the sensor does not have temperature drift at any ambient temperature.
● Small size, easy to carry, suitable for on-site working.
● With gasbag non-slip straps, more comfortable to carry.
● Data storage up to 100groups.
● Super-light aluminum with full shielding shell.
● External package uses engineering plastic, with water-proof, dust-proof.
Specifications
● Measuring principle: Non-dispersive infrared sensor (NDIR)
● Measuring range: 0-2000ppmv SF6 or 0-50ppmv
● Resolution: 0.1ppmv or 0.01ppmv
● Accuracy: ±2%FS(0-1000ppm)
● Repeatability error: ≤±1%
● Sensitivity: 0.1ppmv
● Response time: ≤2s
● Recovery time: ≤5s
● Stability: ≤±20ppm, more than 1000hours
● Zero shift: ≤±1%(F.S/year)
● Linear error: ≤±1%
● Storage temperature: -20~+60℃
● Operation temperature: -20~+50℃
● Sampling mode: Built-in electromagnetic diaphragm pump, automatic slot-in type, flow up to 1L/min.
● Working voltage: 220VAC±10%, 50Hz Or Built-in Li-battery, 8hours working.
● Dimension: 160×220×70mm, hand gun 106mm*170mm*120mm.
● Weight: main unit about 1.5kg, hand gun about 0.5kg
Product detail pictures:
Related Product Guide:
Assume full duty to satisfy all demands of our clients; reach steady advancements by marketing the development of our purchasers; grow to be the final permanent cooperative partner of clientele and maximize the interests of customers for OEM Best Infrared Gas Detector Factory – GDWG-V SF6 Gas Leak Detector (IR type, Double display) – HV Hipot , The product will supply to all over the world, such as: Slovenia, Karachi, Afghanistan, We believe that good business relationships will lead to mutual benefits and improvement for both parties. We have established long-term and successful cooperative relationships with many customers through their confidence in our customized services and integrity in doing business. We also enjoy a high reputation through our good performance. Better performance will be expected as our principle of integrity. Devotion and Steadiness will remain as ever.
Speaking of this cooperation with the Chinese manufacturer, I just want to say"well dodne", we are very satisfied.





