OEM Best instrument of flash point in closed cup Manufacturer – GDFJ-VI Transformer Dissolved Gas Analyzer – HV Hipot
OEM Best instrument of flash point in closed cup Manufacturer – GDFJ-VI Transformer Dissolved Gas Analyzer – HV Hipot Detail:
General Information
GDFJ-VI Transformer Dissolved Gas Analyzer is a portable gas chromatograph suitable for on-site rapid analysis. It integrates chromatographic detection, analysis and diagnosis in one, as well as micro detector, mini gas source and built-in touch screen computer. It has higher integration, better stability, more delicate shape and more convenient operation than traditional portable oil chromatography. On-site analysis can timely analyze and diagnose transformer fault conditions, making power work simpler and more convenient. The instrument adopts the classical three-detector process, and the analytical data are identical with those of the traditional laboratory chromatograph. The instrument adopts advanced small modular design concept. It has high integration, small size and light weight, which is easy to carry to the site for analysis. It provides timely and accurate data for transformer monitoring and test, and saves a lot of manpower and material resources.
A full analysis of the contents of the seven gas components H2, CO, CO2, CH4, C2H4, C2H6, C2H2 (hydrogen, carbon monoxide, carbon dioxide, methane, ethylene, ethane, acetylene) dissolved in the insulating oil can be completed in one injection. The minimum detection concentration of acetylene is 0.1ppm, and has been successfully applied to many industries and departments such as power supply companies, power plants, transformer plants, large-scale smelting enterprises, and railway power supply sections.
Features
● Built-in touch screen anti-control technology to realize visual display of instrument air pressure.
All air pressures are digitally displayed by the pressure sensor. The pressure of the carrier gas, hydrogen gas and air can be directly read through the workstation, and the analysis conditions can be grasped in real time.
● Using touch screen anti-control technology to achieve instrument temperature setting, display and other operations.
All temperature parameters can be displayed digitally. The temperature of column box, detector and reformer can be read and controlled directly by workstation. The operation is simple and clear.
● Touch screen click to complete heating, cooling, ignition and current settings.
Built-in automatic air path control device automatically removes a part of the air when operating on the touch screen, so that the ratio of hydrogen to air reaches the ratio suitable for ignition, and restores the ratio after the ignition is completed automatically; likewise, through the bridge flow setting window in workstation software can complete the setting of the thermal bridge flow.
● Digital FID electronic zero-setting technology to enhance the anti-interference ability of the instrument.
FID detector uses electronic zero-setting technology and high-precision digital circuit to compensate the basic current of FID, so as to realize the electronic regulation of the output signal level of FID. Because the electronic regulation can be directly installed on the signal channel of the circuit board to improve the ability of electronic noise suppression, there is no interference signal when the mechanical potentiometer is connected. Because of reducing parasitic parameters, it has strong anti-interference ability.
● Using computer anti-control technology to achieve control of the oscillator.
Through a connecting signal line, it can provide power for the small oscillator, and through the workstation, it can operate the whole process of the oscillator, such as heating up, starting oscillation, standstill, buzzing prompt at the end, etc.ystem in English and Chinese, which can be switched freely.
● Built-in silent air pump, without external air source.
With an imported small air pump inside the main engine, it can provide air source for the instrument uninterruptedly. Because of the shock-proof design, the air pump can work silently, and the user will hardly feel its existence.
● Gas breakage protection function of thermal conductive tungsten wire.
With intelligent thermal cutoff protection function, when the carrier gas pressure is less than the safety threshold, the system will automatically cut off the thermal conductivity current to protect the thermal conductivity detector from damage.
Minimum detection concentration and limit (Unit μL/L)
|
Component |
Min. detection concentration |
|
H2 |
2 |
|
CO |
5 |
|
CO2 |
10 |
|
CH4 |
0.1 |
|
C2H4 |
0.1 |
|
C2H6 |
0.1 |
|
C2H2 |
0.1 |
FID(flame ionization detector)
● Detection limit: Mt≤3×10-12g/s (Hexadecane/isooctane)
● Baseline noise: ≤5×10-14A
● Baseline shift: ≤1×10-13A/30min
● Linear range: ≥ 106
TCD(thermal conductivity detector)
● Sensitivity: S≥3500mV•ml/mg (conventional); 5000mV•ml/mg (highly sensitive)
● Baseline noise: ≤10μV
● Baseline shift: ≤30μV/30min
● Linear range: ≥104
Temperature control index
|
Temperature control part |
Range |
Accuracy |
|
Column box |
4~ 450℃ above room temperature |
±0.1℃ |
|
Packed column injector |
4~ 450℃ above room temperature |
±0.1℃ |
|
FID Detector |
4~ 450℃ above room temperature |
±0.1℃ |
|
TCD Detector |
4~ 450℃ above room temperature |
±0.1℃ |
|
Ni nickel catalyst reformer |
4~ 450℃ above room temperature |
±0.1℃ |
Others
Dimension: 420*280*300mm
Weight: ˂15kg
Power supply: AC220V±10%, 50Hz
Accessory
| No. | Name | Specification | Qty. |
| 1 | Portable DGA | GDFJ-VI | 1set |
| 2 | Chromatography workstation | Insulating oil special edition | 1set |
| 3 | Miniature Full Automatic Oscillator | 1set | |
| 4 | High Purity Nitrogen | 2L, 99.999%, Aluminum alloy bottled | 2bottles |
| 5 | High Purity Hydrogen | 2L, 99.999%, Aluminum alloy bottled | 1bottle |
| 6 | Standard Gas | 2L, 7 Components, Aluminum alloy bottled | 1bottle |

Product detail pictures:
Related Product Guide:
Our advantages are lower prices,dynamic sales team,specialized QC,strong factories,high quality products and services for OEM Best instrument of flash point in closed cup Manufacturer – GDFJ-VI Transformer Dissolved Gas Analyzer – HV Hipot , The product will supply to all over the world, such as: Norway, Juventus, Guatemala, We have constructed strong and long co-operation relationship with an enormous quantity of companies within this business overseas. Immediate and specialist after-sale service supplied by our consultant group has happy our buyers. Detailed Info and parameters from the merchandise will probably be sent to you for any thorough acknowledge. Free samples may be delivered and company check out to our corporation. n Portugal for negotiation is constantly welcome. Hope to get inquiries type you and construct a long-term co-operation partnership.
This supplier's raw material quality is stable and reliable, has always been in accordance with the requirements of our company to provide the goods that quality meet our requirements.





