GDPD-306M is widely used in the partial discharge detection of power systems. Including high voltage switchgear, ring mains, voltage/current transformer, transformer (include dry type transformer), GIS, overhead lines, cables, and other equipment insulation state detection.
The following indicators are used to measure the degree of discharge of electrical equipment:
Partial discharge intensity detection: By measuring the discharge signal in a power frequency cycle, the intensity of the partial discharge is characterized according to the maximum value (dB) in the discharge pulse sequence.
Partial discharge frequency detection: The device measures the discharge signal within a power frequency cycle, extracts the discharge pulses and characterizes the frequency of partial discharges according to the number of discharge pulses.
Features
● With different sensors to achieve partial discharge detection of almost all electrical equipment.
● Provide multiple discharge patterns such as time-domain waveform, PRPD, PRPS, etc., to realize the analysis of different discharge types.
● User-friendly man-machine interface facilitates the data management of different devices, including the traceability of historical data change trends, horizontal and vertical data analysis, and realizes a 360° comprehensive diagnosis of the tested device.
● Built-in ultrasonic sensor and transient earth voltage (hereinafter referred to as TEV) sensor, also can be connected to external special sensors for transformers, GIS, overhead lines, and cables.
● It adopts non-intrusive detection method, no need to power off during the test process, no need to configure additional high voltage source, it is more convenient to use than traditional pulsed partial discharge detector.
● The test bandwidth range is 30kHz ~ 2.0GHz, suitable for detection principles of various frequency bands.
Specifications
| TEV Measurement | UHF Measurement | ||
| Measurement range | 0-60dBmV | Detection frequency band | 300~1500MHz |
| Resolution | 1dB | Measurement range | -75-0dBmV |
| Accuracy | ±1dB | Accuracy | <1dBmV |
| Max. pulse per cycle | 1400 | Sensor frequency band | 300-2000MHz |
| Measurement frequency band | 1~100MHz | ||
| AA measurement | AE measurement | ||
| Measurement range | -6dBμV~68dBμV | Measurement range | -6dBμV~68dBμV |
| Resolution | 1dB | Resolution | 1dB |
| Accuracy | ±1dB | Accuracy | ±1dB |
| Sensor center frequency | 40kHz | Frequency range | 40-200kHz |
| HFCT measurement | |||
| Sensor transmission impedance | 5mV/mA | ||
| Detection frequency | 1~30MHz | ||
| Sensitivity | ≤50pC | ||
| Hardware | |||
| Shell | ABS | ||
| Display | 4.0inch RGB LCD screen | ||
| Controller | ARM | ||
| Connector | USB interface (charger port), Wireless WIFI 3.5mm stereo headphone jack, Wireless synchronization benchmark External ultrasonic sensor input |
||
| Headphone | 8ohm minimum | ||
| SD card | Standard 16G | ||
| Built-in battery | 3.7V/1Ah lithium battery | ||
| Working time | About 8 hours | ||
| Charger | AC 90-264V or DC 5V | ||
| Working temperatures | -20~+50℃ | ||
| Humidity | 20~85% relative humidity | ||
| Dimension, weight | 210*100*35(mm), 0.4kg (main unit) | ||
Packing List
| Main unit |
1 |
Standard |
| External Contact ultrasonic sensor |
1 |
For option, used for transformers, GIS, motors |
| UHF sensor |
1 |
For option, used for GIS |
| HFCT |
1 |
For option, used for power cable |
| Test cable |
1 |
Standard |
| Charger |
1 |
Standard |
| USB cable |
1 |
For charging and PC communication |
| User’s guide |
1 |
|
| Factory test report |
1 |
Product detail pictures:
Related Product Guide:
We pursue the management tenet of "Quality is superior, Service is supreme, Reputation is first", and will sincerely create and share success with all clients for OEM Best instrument transformer Manufacturers – GDPD-306M Portable Ultrasonic Partial Discharge Detector – HV Hipot , The product will supply to all over the world, such as: Japan, Niger, European, We provide good quality but unbeatable low price and the best service. Welcome to post your samples and color ring to us .We will produce the goods according to your request. If you are interested in any products we offer, please feel free to contact us directly by mail, fax, telephone or internet. We are here to answer your questions from Monday to Saturday and looking forward to cooperating with you.