OEM Best Lightning Arrester Tester Factory – GDUD-PTM Ultrasonic Flaw Detector for Electrical Power Tower – HV Hipot

OEM Best Lightning Arrester Tester Factory – GDUD-PTM Ultrasonic Flaw Detector for Electrical Power Tower – HV Hipot

Brief Description:


Product Detail

Product Tags

Related Video

Feedback (2)

"Sincerity, Innovation, Rigorousness, and Efficiency" could be the persistent conception of our enterprise to the long-term to produce together with clients for mutual reciprocity and mutual profit for Standard Capacitor, Apa Itu Partial Discharge, Oil Tan Delta Test, The concept of our company is "Sincerity, Speed, Service, and Satisfaction". We will follow this concept and win more and more customers' satisfaction.
OEM Best Lightning Arrester Tester Factory – GDUD-PTM Ultrasonic Flaw Detector for Electrical Power Tower – HV Hipot Detail:

Features

● TFT true color screen.
● Using leading embedded digital system technology, the electrical performance indicators of the instruments are designed and manufactured according to the standard EN 12668.1 – 2000.
● Advanced and safe lithium polymer battery and power management technology, automatic alarm and protection. The automatic standby screen saver can be set to make the equipment more energy-efficient and longer-lasting, and to ensure continuous and efficient flaw detection.
● Application software that integrates intelligent and powerful processing functions, direct-reading user interface and operation mode, or digital knob one-button operation mode.
● Large-capacity detection parameters preset channel, convenient for users to operate on different detection objects. Powerful data storage and static analysis capability, coupled with real-time flaw detection date and time synchronization clock tracking and recording, make detection easier.
● With variable width square wave pulse generator, and variable voltage transmitter to get variable transmitting power. Multi-stage damping settings allow the probe to be optimally matched to the instrument.
● Good amplifier characteristics and frequency band characteristics. The amplifier has an accuracy of 0.1dB, with wide-band and narrow-band operation modes, and probe frequency can be measured real time, which provides better detection results when the user detects different materials.
● With wide detection range(up to 6 meters) and powerful signal resolution, min. 0.1mm continuous adjustable range. Choose a suitable range and the corresponding probe for good near-field resolution.
● Excellent high-speed hardware real-time processing and optimized design of pulse repetition frequency control function to meet the best effect for different crystal grains and detection distance. The echo display has dynamic effect and no hysteresis.
● Automatic calibrations for probe and curvature surface, which optimizes the coupling between the probe and test object and ensures accuracy.
● With distance-amplitude (DAC) curve function, program-controlled sound and light alarm control.
● With high-speed USB interface, easily communicate with the computer, support computer management processing functions and online programming.
● Light aluminum alloy hand held housing, which has excellent anti-interference performance. Meets IP65 protection class.

Specifications

Transmitting/Receiving

Transmitting voltage 600V
Sampling frequency 100MHz(Max.)
Pulse repetition frequency  60Hz
Impedance matching 50Ω/500Ω
Working mode Self-transmitting and receiving/ Single transmitting and single receiving/ Penetrating
Resolution ≥36dB(5N14)
Average electrical noise ≤

Amplify/detect

Sensitivity margin ≥60dB(200mm deep, Φ2Flat bottom hole)
Gain 0~110dB, step 0dB/0.1dB/1dB/2dB/6dB for selection
Amplifier accuracy ±1dB
Vertical linearity error ≤3%
Automatic gain 10%-90%
Dynamic Range ≥35dB

Time base

Detection range 10-6000mm, 0.1,1 and 10mm step automatic setting
Horizontal linearity error ≤0.1%
Sound speed 1000-16000m/s, step is 1m/s
Zero offset
(probe delay)
0-500.0us
Display pan 0-1000.0mm;0.1, 1mm step automatic setting

Curve

DAC curve Distance-amplitude curve(DAC), 2~10pcs reference point
4 additional correctable dB curves

Signal Processing

Signal suppression 0-90%, linear
 
Detection gate
(1 piece)
Starting point / width / height continuously adjustable
Positive/negative alarm in the gate
Output (sound and light alarm) control
Signal measurement point selection in the gate
Measurement mode Sound path/horizontal distance/depth real-time calculation display
TOF (time of flight) measurement real-time calculation display
Dynamic display of sound path refraction
Static reading measurement calculation
Optional reference quantification and positioning

Flaw detection function

Channel 20groups
Storage 500 echo signals
Display Full freeze/reference freeze
Envelope curve Peak envelope record display
Real time clock Date/time tracking, standard clock timing
Interface USB port, supporting computer communication and management

Display

Display High-bright, true color TFT display, 5.7 inches
Frequency NTSC(60Hz)

Structure and use environment

Battery Lithium polymer battery, working time ≥ 10 hours
Dimension and weight 210mmx165mmx50mm,1.8kg(with battery)
Environment temperature -5℃–60℃
Relative humidity 20-90%RH

Accessories

Main Unit 1 piece
Power adapter 1 piece
HF anti-EMI probe cable 2 pieces
USB cable 1 piece
Probe 2 pcs
Module 1 piece
CD 1 piece
User’s Guide 1 copy
Factory Test Report 1 copy

Product detail pictures:

OEM Best Lightning Arrester Tester Factory –  GDUD-PTM Ultrasonic Flaw Detector for Electrical Power Tower – HV Hipot detail pictures

OEM Best Lightning Arrester Tester Factory –  GDUD-PTM Ultrasonic Flaw Detector for Electrical Power Tower – HV Hipot detail pictures

OEM Best Lightning Arrester Tester Factory –  GDUD-PTM Ultrasonic Flaw Detector for Electrical Power Tower – HV Hipot detail pictures

OEM Best Lightning Arrester Tester Factory –  GDUD-PTM Ultrasonic Flaw Detector for Electrical Power Tower – HV Hipot detail pictures


Related Product Guide:

We take "customer-friendly, quality-oriented, integrative, innovative" as objectives. "Truth and honesty" is our administration ideal for OEM Best Lightning Arrester Tester Factory – GDUD-PTM Ultrasonic Flaw Detector for Electrical Power Tower – HV Hipot , The product will supply to all over the world, such as: Leicester, Egypt, New Delhi, We rely on high-quality materials, perfect design, excellent customer service and the competitive price to win the trust of many customers at home and abroad. 95%products are exported to overseas markets.
  • Superb technology, perfect after-sales service and efficient work efficiency, we think this is our best choice.
    5 Stars By Nina from Haiti - 2018.12.30 10:21
    The supplier cooperation attitude is very good, encountered various problems, always willing to cooperate with us, to us as the real God.
    5 Stars By Elaine from kazan - 2017.05.21 12:31

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us