OEM Best Measure Capacitor In Circuit Supplier – High voltage divider GDFR-D1 – HV Hipot

OEM Best Measure Capacitor In Circuit Supplier – High voltage divider GDFR-D1 – HV Hipot

Brief Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We support our consumers with ideal good quality merchandise and large level provider. Becoming the specialist manufacturer in this sector, we have attained wealthy practical encounter in producing and managing for Dc Tester, Capacitor Discharge Unit, Dc Capacitor, We usually concertrating on acquiring new creative products to fulfill request from our clientele all around the world. Be a part of us and let's make driving safer and funnier jointly!
OEM Best Measure Capacitor In Circuit Supplier – High voltage divider GDFR-D1 – HV Hipot Detail:

GDFR-D1 series AC/DC Voltage Meter

GDFR-D1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. The digital meter and divider are equipped in one unit. 

Features

● Balance type equal potential shield structure.
● Fully-sealed insulation cylinder with internal excellent components.
● High accuracy and linearity, good stability and anti-interference ability.
● With good filling materials, which make the structure smaller and weight lighter, and minimize internal partial discharge.
● Small size, light weight, easy to carry in the field work.
● Inner shield anti-interference system.
● The voltage ratio can be customized, suitable for calibration.
● External voltage meter can be connected.

Technical Specifications

Model No. GDFR-D1-50 GDFR-D1-100 GDFR-D1-150 GDFR-D1-200 GDFR-D1-300 GDFR-D1-400
Voltage(kV) 50 100 150 200 300 400
DC frequency(Hz) <2
AC frequency(Hz) 30-300
Accuracy
(G type)
AC: 1.0%/DC: 0.5% –
Accuracy
(H type)
AC: 0.5%/DC: 0.5% – –
Impedance
(MΩ)
650 1280 2000 2640 4000 5360
Capacitance
(pF)
500 250 400/160 300 200 300
Voltage ratio 1000:1 or 10000:1(or customized)
Height (mm) 500 650 900 1200 1750 2350
Dimension
(mm)
150×150 160×160 200×200 260×260 800×800
Cable impedance(Ω) 50 / 75
Range 1. Low range: 0-20kV
2. High range: 20kV-rated voltage
1. Low range: 0-200kV
2. High range: 200kV-rated voltage
Cable length(m) 3 4 5 6 8 10
Weight(kg) 5.5 6.9 10.6 14.1 23.5 48.2
Packing Medium Imported dry type high polymer materials
Operation temperature 0℃-45℃
Relative humidity <85%RH, no condensation
Altitude <1500m(or customized)
Use condition Indoor use or outdoor use in Sunny day

Product detail pictures:

OEM Best Measure Capacitor In Circuit Supplier –  High voltage divider GDFR-D1 – HV Hipot detail pictures


Related Product Guide:

Our company has been focusing on brand strategy. Customers' satisfaction is our best advertising. We also supply OEM service for OEM Best Measure Capacitor In Circuit Supplier – High voltage divider GDFR-D1 – HV Hipot , The product will supply to all over the world, such as: Finland, Barbados, Greenland, On today, we've got customers from all over the world, including USA, Russia, Spain, Italy, Singapore, Malaysia, Thailand, Poland, Iran and Iraq. The mission of our company is to deliver the highest quality products with best price. We've been looking forward to doing business with you!
  • The company keeps to the operation concept "scientific management, high quality and efficiency primacy, customer supreme", we have always maintained business cooperation. Work with you,we feel easy!
    5 Stars By Eunice from Pakistan - 2017.08.16 13:39
    Product variety is complete, good quality and inexpensive, the delivery is fast and transport is security, very good, we are happy to cooperate with a reputable company!
    5 Stars By Lindsay from Mexico - 2017.03.08 14:45

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us