OEM Best pd sensor Manufacturers – GDJF-2007 Digital Partial Discharge Analyzer – HV Hipot
OEM Best pd sensor Manufacturers – GDJF-2007 Digital Partial Discharge Analyzer – HV Hipot Detail:
Picture only for reference first.
GDJF-2007 Digital Partial Discharge Analyzer is widely used for detecting partial discharge of high voltage equipment such as power transformers, instrument transformer, HV circuit breaker, GIS, Zinc oxide surge arrester, power cable. It also can make type tests and monitor insulation operation.
It includes main unit, PD software, current transformer, input unit, calibration pulse generator, input adapter, antenna amplifier and connection cable etc.
Features
● 12inch LCD display, with portable design, rugged and durable, easy to use.
● Strong anti-interference ability, accurate. Using digital filtering technology, field interference can be effectively eliminated, and partial discharge measurement can be realized in a strong interference environment.
● Multi-channel data acquisition. One screen can display 2channels or 4channels waveform.
● Powerful software function. With PD measurement, analysis, PD repeated discharge times N measurement, analysis and anti-fixed interference, anti-dynamic interference. Free choice of ellipse, straight line and sinusoidal display mode. Measure and Observe discharge pulse by window, and test voltage and current, partial discharge can be measured at the same time. All test data of 2channels can be saved timely. Test waveform can be saved, re-displayed and analyzed. The gain range of each channel can be coarse adjusted and fine adjusted. Digital window-opening technology, to avoid the influence of interference on measurement. Phase window opening, single window and double window can be selected. Window can be opened freely within 360degree.
● Accorded with IEC60270 standard.
Specifications
● Capacitance range: 6pF-250μF
● Sensitivity: 0.1pc
● Measurement channel: 2 or 4pcs independent channels
● Sampling accuracy: 12Bit
● Sampling rate: Max. 100MHz per channel
● Measurement range: 0.1pc-10000nc.
● Dynamic range: >80db.
● Measurement frequency band: 10kHz-1MHz at 3db.
● Frequency range of test power: 50-400Hz.
● Programmable filter
Low frequency: 10K, 20K, 40K, 80K;
High frequency: 100K, 200K, 300K, 1000K.
● Environmental temperature: -15℃–50℃
● Relative humidity: ≤95% (20℃)
● Altitude: ≤3000m.
● Impact ability: 5000V at each input port and power terminal (positive, negative and AC)
● Power input: AC220V±10%, 45-65Hz, power <500W.
● Weight: about 15kg.
● Dimension: 58*36*32CM
Product detail pictures:
Related Product Guide:
We take "customer-friendly, quality-oriented, integrative, innovative" as objectives. "Truth and honesty" is our administration ideal for OEM Best pd sensor Manufacturers – GDJF-2007 Digital Partial Discharge Analyzer – HV Hipot , The product will supply to all over the world, such as: Malaysia, Thailand, Lithuania, Profession, Devoting are always fundamental to our mission. We've got always been in line with serving customers, creating value management objectives and adhering to the sincerity, dedication, persistent management idea.
By Pandora from Sevilla - 2018.06.09 12:42
We have been engaged in this industry for many years, we appreciate the work attitude and production capacity of the company, this is a reputable and professional manufacturer.
By jari dedenroth from Madras - 2018.02.12 14:52