OEM Best power usage meter test Factories – GDPQ-300A Handheld Power Quality Analyzer – HV Hipot
OEM Best power usage meter test Factories – GDPQ-300A Handheld Power Quality Analyzer – HV Hipot Detail:
Features
● The instrument is a high-precision test instrument specially used to detect power quality problems such as waveform distortion, harmonic content and three-phase unbalance in the power grid. It also has the functions of electrical parameter test and vector analysis.
● Can accurately measure voltage, current, active power, reactive power, phase angle, power factor, frequency and other electrical parameters.
● It can display the vector diagram of the measured voltage and current. The user can analyze the vector diagram to get the correctness of the wiring of the metering equipment.
● The current is measured by a clamp-type transformer. Operator does not need to disconnect the current loop when measuring with a clamp-type current transformer, the measurement can be conveniently and safely performed. Different ranges of clamps can be selected according to the user’s measurement range.
● It can measure and analyze the AC power quality supplied by the utility grid to the customer. It can measure and analyze: frequency deviation, voltage deviation, three-phase voltage allowable unbalance and grid harmonics.
● It can display single-phase voltage and current waveforms and simultaneously display three-phase voltage and current waveforms.
● All test interfaces have a screen lock function to facilitate user reading and analysis of data.
● Load fluctuation monitoring: Measurement and analysis of the fluctuations of various electrical equipment caused by the power quality of the utility grid under different operating conditions. Timing records and stores trends in voltage, current, active power, reactive power, apparent power, frequency, phase, and other power parameters.
● Dynamic monitoring of power equipment adjustment and operation process to help users solve problems in the process of power equipment adjustment and commissioning.
● Ability to test and analyze the dynamic parameters of reactive power compensation and filtering devices in power systems and quantitatively evaluate their functions and technical indicators.
● Can set different storage interval time, continuously store data according to the set time interval;
● Built-in large-capacity data storage, it can be stored continuously for more than 18 months at 1 minute interval, which can meet the needs of long-term monitoring test points.
● The instrument has a USB interface, which can easily copy data directly to the background management computer.
● In conjunction with powerful data management software, real-time sampled data can be directly uploaded to the background management computer for more comprehensive and faster processing in the background.
● With a perpetual calendar, clock function, real-time display date and time. Test data and results can be saved at the same time, and uploaded to the computer through the serial port, through the background management software (optional) to achieve data micro-computer management, with powerful reporting capabilities.
● It adopts LCD large-screen as the display, English operation interface and LCD display interface with English character prompt information and multi-parameter display. The human-machine dialogue interface is friendly.
● 3 minutes no operation LCD display automatically enters the power saving mode, in order to maximize battery life.
● Conductive silicone button, feel good, long life, reasonable design, easy to operate.
● Built-in high-capacity, high-performance lithium-ion rechargeable battery, can work over 10 hours after fully charged.
● Small size, light weight, easy to carry, can be used for on-site measurement, can also be used as a laboratory standard measurement equipment.
Specifications
|
Input |
|
|
Voltage measurement range |
0-200V-800V, auto switching |
|
Current measurement range |
CT: 5A/25A (standard) 100A/500A (optional) 400A/2000A (optional) |
|
Phase angle measurement range |
0~359.99° |
|
Frequency measurement range |
45~65Hz |
|
Voltage channel |
3 channel (UA, UB, UC) |
|
Current channel |
3 channel (IA, IB, IC) |
|
Maximum harmonic analysis times |
63 times |
|
Maximum continuous storage period of 1 minute interval |
18 months |
|
Accuracy |
|
|
Electrical parameter measurement section |
|
|
Voltage |
±0.2% |
|
Frequency |
±0.01Hz |
|
Current, power |
±0.5% |
|
Phase |
±0.2° |
|
Power quality part |
|
|
The fundamental voltage tolerance error |
≤0.5%F.S. |
|
Fundamental current tolerance error |
≤1%F.S. |
|
Measurement error of phase difference between fundamental voltage and current: |
≤0.2° |
|
Harmonic voltage content measurement error |
≤0.1% |
|
Harmonic current content measurement error |
≤0.2% |
|
Three-phase voltage imbalance error: |
≤0.2% |
|
Voltage deviation error |
≤0.2% |
|
Voltage variation error |
≤0.2% |
|
Working temperature |
-10℃~ +40 ℃ |
|
Charging power |
AC 220V , 45Hz-55Hz |
|
host power consumption |
≤3VA |
|
the maximum working time of the battery |
≤10 hours |
|
Insulation |
(1) The insulation resistance of the voltage and current input terminals to the casing is ≤100MΩ. (2)The working power input end is subjected to a power frequency of 1.5KV (effective value) between the outer casings, and it takes 1 minute to test. |
|
Dimension |
320mm *240mm *130mm |
|
Weight |
2.0kg |
Product detail pictures:
Related Product Guide:
Our company insists all along the quality policy of "product quality is base of enterprise survival; customer satisfaction is the staring point and ending of an enterprise; persistent improvement is eternal pursuit of staff" and the consistent purpose of "reputation first, customer first" for OEM Best power usage meter test Factories – GDPQ-300A Handheld Power Quality Analyzer – HV Hipot , The product will supply to all over the world, such as: USA, Brunei, South Africa, We will continue to devote ourselves to market & product development and build a well-knit service to our customer to create a more prosperous future. Please contact us today to find out how we can work together.
The company has a good reputation in this industry, and finally it tured out that choose them is a good choice.

便携式冷镜法SF6气体露点仪.jpg)



