OEM Best Pulse Generator Impulus Signallar Manbaai Factories – Impulse Voltage Test System – HV Hipot
OEM Best Pulse Generator Impulus Signallar Manbaai Factories – Impulse Voltage Test System – HV Hipot Detail:
Features
● Complete equipment and wide voltage levels in the whole set of device.
● Small electric inductance in the return circuit of the impulse voltage generator, A band-stop filtering is adopted so that a standard impulse wave is still generated even under a large capacity load, and large load capacity.
● Large in voltage utilization coefficient.
● Convenient in wave adjustment, simple in operation, excellent in synchronization performance and reliable in motion.
● An automatic control technique is adopted in the constant-current charge, which is high automation and strong anti-interference capacity.
● A digital measurement and analysis system for the impulse test date are adopted, which increase the technical level and the efficiency of the impulse voltage tests.
Specifications
| Impulse voltage grade | 100kV-7200kV |
| Standard lightning wave | 1.2±30%/50±20%µS |
| Peak oscillation | <5% |
| Standard switching wave | 250±20%/2500±60%µS |
| Virtual front time of oscillating lightning wave | ≤15µS |
| Virtual front time of oscillating switching wave and virtual front time of oscillating switching impulse wave |
15µS-1mS |
| The minimum output voltage | ≥10%Un |
| Charging voltage instability | <±1% |
| Synchronizing range | ≥20% |
| Synchronous discharge error rate | <2% |
| Ignition range | 10%~100% |
| Working time | ≥70%UN Discontinuous work (charge-discharge 300s/time) <70%nn Continuous work (charge-discharge 120s/time) |
| Generator efficiency: lightning wave (no load) | ≥90% |
| Time to chopping | 2~5µS |
Product detail pictures:
Related Product Guide:
Often customer-oriented, and it's our ultimate target to become not only probably the most reputable, trustable and honest provider, but also the partner for our customers for OEM Best Pulse Generator Impulus Signallar Manbaai Factories – Impulse Voltage Test System – HV Hipot , The product will supply to all over the world, such as: Cologne, Brasilia, UAE, So far our products have been exported to east Europe, the Middle East, Southeast, Africa and South America etc. We have 13years professional sales and purchase in Isuzu parts at home and abroad and the ownership of the modernized electronic Isuzu parts checking systems. We honor our core principal of Honesty in business, priority in service and will do our best to offer our customers with high quality products and excellent service.