OEM Best Step Pulse Generator Factory – GDOT-3B 100kV 3 Cups Insulation Oil Breakdown Voltage (BDV)Tester – HV Hipot
OEM Best Step Pulse Generator Factory – GDOT-3B 100kV 3 Cups Insulation Oil Breakdown Voltage (BDV)Tester – HV Hipot Detail:
Standards
IEC 156: 1995 Insulating liquids- Determination of the breakdown voltage at power frequency
Features
● Adopts a microprocessor, three cups in one, and automatically completes the operations of boosting, holding, stirring, standing, calculating, printing, etc., and can perform oil circulation withstand voltage test in the range of 0-100kV.
● LCD screen display.
● The operation of this instrument is simple, the operator only needs to make simple settings, and the instrument will automatically complete the test of 1-3 oil samples according to the settings. For each oil sample, the breakdown voltage value and number of cycles are automatically stored. After the test is completed, the thermal printer can print out the breakdown voltage value and average value of each oil sample.
● Power-down hold, can store 100 test results, and can display the current ambient temperature and humidity.
● It adopts single-chip microcomputer control for uniform speed boost, and the voltage frequency is accurate to 50Hz, making the whole process easy to control.
● With over-voltage, over-current limit and other protection to ensure the safety of operators.
● With temperature measurement display function and system clock display.
● Standard RS232 interface, can communicate with computer.
Specifications
|
Output voltage |
0-100kV optional |
|
Power distortion rate |
<3% |
|
Voltage increasing speed |
0.5~5kV/s adjustable |
|
Display |
Large LCD screen |
|
Electrode gap |
standard 2.5mm |
|
Boost times |
1~10 times |
|
Standing time |
15 min (adjustable) |
|
Boost interval |
5 minutes (adjustable) |
|
Booster capacity |
1.5kVA |
|
Measurement accuracy |
±3% |
|
Power input |
AC220V± 10%, 50Hz±1Hz |
|
Power |
200W |
|
Working temperature |
0-45℃ |
|
Humidity |
<75%RH |
|
Dimension |
585mm*390mm*410mm |
|
Weight |
43kg |
Accessories
| GDOT-3B Tester | 1 set |
| Oil cup | 3 pc |
| Power cord | 1 pc |
| Ground cable | 1 pc |
| Spare fuse | 2 pcs |
| Stirring nut | 2 pcs |
| Standard gauge 2.5mm | 1 pc |
| Tweezer | 1 pc |
| Print paper | 1 rolls |
| Allen wrench | 1 pc |
| User’s guide | 1 pc |
| Factory test report | 1 pc |
Product detail pictures:
Related Product Guide:
As for competitive selling prices, we believe that you will be searching far and wide for anything that can beat us. We will state with absolute certainty that for such excellent at such charges we are the lowest around for OEM Best Step Pulse Generator Factory – GDOT-3B 100kV 3 Cups Insulation Oil Breakdown Voltage (BDV)Tester – HV Hipot , The product will supply to all over the world, such as: Ecuador, Colombia, Belarus, Most problems between suppliers and clients are due to poor communication. Culturally, suppliers can be reluctant to question things they do not understand. We break down those barriers to ensure you get what you want to the level you expect, when you want it. Faster delivery time and the product you want is our Criterion .