OEM Best Tan Delta Of Transformer Oil Suppliers – DC High Voltage Generator GDZG-300 – HV Hipot
OEM Best Tan Delta Of Transformer Oil Suppliers – DC High Voltage Generator GDZG-300 – HV Hipot Detail:
Features
● Simple operation and complete function, easy for wild work.
● Higher voltage stability, smaller ripple coefficient.
● More reliable and stable, continuous short-circuit discharge directly to ground.
● Intelligent grounding protection and alarm function. High precision, accurate measurement, digital display of voltmeter and ammeter, with voltage resolution 0.1kV, and current 0.1uA.
● High stability of voltage regulation, smooth voltage boosting process, high adjustable precision, with coarse and fine adjustment functions. Accuracy of voltage regulation better than 0.1%, voltage and current measurement error is less than 1.0%, ripple factor better than 0.5%.
● With function of high-accuracy 75%VDC-1mA, more convenient for zinc oxide lighting arrester DC testing.
● HV booster is small size and large capacity, with △-Y shoring in the packing, which is portable to carry.
Specifications
Rated voltage |
40kV/60kV/120kV/200kV/300kV/500kV |
Rated current |
2mA/3m A/4mA/5mA/10mA |
Power supply |
AC 220V±10%, 50Hz |
Ripple coefficient |
≤1.0% |
Voltage meter precision |
± (1.0 %reading±2 digit) |
Current meter precision |
± (1.0 %reading±2 digit) |
Voltage stabilization |
Stochastic wave, ≤1% when power wave±10% |
Environment temperature |
-10 ~ 40℃ |
Relative humidity |
≤85% (no condensate) |
Product detail pictures:
Related Product Guide:
Along with the "Client-Oriented" enterprise philosophy, a rigorous high-quality control process, superior production products along with a robust R&D group, we constantly deliver premium quality products, exceptional solutions and aggressive costs for OEM Best Tan Delta Of Transformer Oil Suppliers – DC High Voltage Generator GDZG-300 – HV Hipot , The product will supply to all over the world, such as: Uruguay, Tanzania, Kazakhstan, Our business activities and processes are engineered to make sure our customers have access to widest range of products with the shortest supply time lines. This achievement is made possible by our highly skilled and experienced team. We look for people who want to grow with us around the globe and stand out from the crowd. We now have people who embrace tomorrow, have vision, love stretching their minds and going far beyond what they thought was achievable.