OEM Best Underground Utility Locating Services Manufacturer – GD-7018A Optical Fiber Identifier – HV Hipot

OEM Best Underground Utility Locating Services Manufacturer – GD-7018A Optical Fiber Identifier – HV Hipot

Brief Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We keep on with our business spirit of "Quality, Performance, Innovation and Integrity". We goal to create much more worth for our customers with our rich resources, state-of-the-art machinery, experienced workers and exceptional providers for Oil Tan Delta And Resistivity Tester, Partial Discharge Equipment, Tan Delta Test For Switchgear, We sincerely do our best to offer the best service for all the clients and businessmen.
OEM Best Underground Utility Locating Services Manufacturer – GD-7018A Optical Fiber Identifier – HV Hipot Detail:

The GD-7018 series optical fiber pipeline identifier can accurately locate and meaure depth of the underground pipelines, cables and optical cables under the condition of without digging, and accurately find the damage points of the outer coating of the underground pipelines and the location of the underground cable fault points. The instrument incorporates the most advanced technologies such as ultra-narrow band filter, Bluetooth wireless communication, GPS positioning, automatic data mapping by professional data analysis software and automatic generation of test reports. The detection and inspection of various kinds of metal pipelines, pipeline management and maintenance, municipal planning and construction, pipeline inspection in power supply and other departments is one of the necessary instruments for pipeline maintenance units.

Features

(1) Multiple functions
1. Transmitter function: It has three signal application modes of induction method, direct method and clamp method, suitable for different occasions.
2. Receiver function: Used to measure the location, direction, burial depth and current in underground pipes and cables.
3. The left and right positioning arrows indicate the location of the target pipeline, and the locationg is fast and accurate; the front and rear arrows and the dB value indicate the location and size of the damage point of the anticorrosive layer.
4. With backlight function, suitable for emergency rescue at night.
5. GPS geographic positioning function, automatic pipeline mapping.
6. Professional data analysis software, automatic generation of test report.
7. The unique functions of the 7018E receiver: It is used to locate faults (pipeline failure refers to the damage of the outer anti-corrosion layer, cable failure refers to the damage of the outer protective layer), and to detect the insulation damage of underground pipelines.
8. Current measurement: measure the current applied by the transmitter to the pipeline under test.
9. Multimeter function: it can measure output voltage, line voltage, line current, impedance and power. Test the continuity and insulation quality of the cable before and after the cable fault search.
10. External induction clamp: suitable for the place where the signal cannot be directly connected when detecting the cable.

(2) High positioning accuracy
1. A variety of measurement modes for pipeline positioning (valley mode, peak mode, wide peak mode, peak arrow mode) can be mutually verified to ensure the accuracy of pipeline positioning.
2. Maximum method: peak mode, wide peak mode, peak arrow mode can be used to measure the change of horizontal component ((HX)) or horizontal gradient (△HX), and locate according to the position of its maximum value;
3. The minimum method: Use the bottom mode to determine the position of the minimum value by measuring the change of the vertical component (HZ).

(3) There are many sounding methods
1. A variety of detecting methods can be arbitrarily selected and can be mutually verified.
2. Direct reading method with dual horizontal coils.
3. Single level coil 80% method, 50% method.
4. 45 degree method.

(4) Strong anti-interference
1. Many observation parameters: both horizontal component (HX), vertical component (HZ) and horizontal gradient (△HX) can be measured.
2. High transmit power: The output power of the transmitter is up to 10W and is continuously adjustable. It can be arbitrarily selected according to needs.
3. More working frequencies:
Transmitter frequency: 128Hz, 512Hz, 1KHz, 2KHz, 8KHz, 33KHz, 65KHz, 83KHz.
Receiver frequency: radio, 50Hz, 100Hz, 512Hz, 1KHz, 2KHz, 8KHz, 33KHz, 65KHz, 83KHz.
4. According to the characteristics of the target pipeline (material, structure, buried depth, length, etc.), select the appropriate working frequency.

(5) Easy operation
1. Intuitive: A graphic display is used to continuously and real-time display various parameters and signal strength during the detection process.
2. Automatic: Automatically switch to the dual-level antenna mode and automatically adjust the receiver sensitivity when measuring the depth, so as to achieve the best measurement signal, and automatically return to the working mode before after completed.

(6) Long continuous working time and low use cost
The transmitter is equipped with a large-capacity lithium battery pack, which can meet the power supply needs of one field day for field detection by one charge, and can be recycled, which greatly reduces the cost of detection.

(7) Transmitter –AC and DC dual-use
Under normal situations, if the transmitter battery is full, use the built-in battery pack to supply power. If during use, the transmitter battery is low, but the detection task is not completed, you can directly connect a dedicated power adapter, the instrument can be used normally, without having to wait for the instrument to be fully charged before use.

Specifications

Technical Parameter A series B series C series D series E series
Locating Frequency 5 6 7 8 10
Frequency 512,1K,33K,83K 512,1K,33K,83K 512,1K,33K, 83K 512,1K,33K,65K,83K 512, 1K, 2K, 33K, 65K, 83K
Passive Frequency 50Hz 50Hz 100Hz 50Hz 100Hz radio 50Hz 100Hz  radio 50Hz 100Hz  radio
Power Filter × × √ √ √
Fault Frequency × × × × 2
Fault locating × × × × √
 Lithium ion battery √ √ √ √ √
A Frame × × × × √
Locating Depth(m) 6 6 6 6 6
Data storage × × × √ √

Product detail pictures:

OEM Best Underground Utility Locating Services Manufacturer –  GD-7018A Optical Fiber Identifier – HV Hipot detail pictures


Related Product Guide:

"Sincerity, Innovation, Rigorousness, and Efficiency" is the persistent conception of our firm to the long-term to develop together with consumers for mutual reciprocity and mutual advantage for OEM Best Underground Utility Locating Services Manufacturer – GD-7018A Optical Fiber Identifier – HV Hipot , The product will supply to all over the world, such as: Romania, Qatar, Swansea, We also provide OEM service that caters to your specific needs and requirements. With a strong team of experienced engineers in hose design and development, we value every opportunity to provide best products and solutions for our customers.
  • Goods just received, we are very satisfied, a very good supplier, hope to make persistent efforts to do better.
    5 Stars By Muriel from Turin - 2017.04.28 15:45
    The company has rich resources, advanced machinery, experienced workers and excellent services, hope you keep improving and perfecting your products and service, wish you better!
    5 Stars By Phyllis from Grenada - 2018.10.31 10:02

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us