OEM Best Voltage Testing Equipment Suppliers – GDOT-3B 100kV 3 Cups Insulation Oil Breakdown Voltage (BDV)Tester – HV Hipot
OEM Best Voltage Testing Equipment Suppliers – GDOT-3B 100kV 3 Cups Insulation Oil Breakdown Voltage (BDV)Tester – HV Hipot Detail:
Standards
IEC 156: 1995 Insulating liquids- Determination of the breakdown voltage at power frequency
Features
● Adopts a microprocessor, three cups in one, and automatically completes the operations of boosting, holding, stirring, standing, calculating, printing, etc., and can perform oil circulation withstand voltage test in the range of 0-100kV.
● LCD screen display.
● The operation of this instrument is simple, the operator only needs to make simple settings, and the instrument will automatically complete the test of 1-3 oil samples according to the settings. For each oil sample, the breakdown voltage value and number of cycles are automatically stored. After the test is completed, the thermal printer can print out the breakdown voltage value and average value of each oil sample.
● Power-down hold, can store 100 test results, and can display the current ambient temperature and humidity.
● It adopts single-chip microcomputer control for uniform speed boost, and the voltage frequency is accurate to 50Hz, making the whole process easy to control.
● With over-voltage, over-current limit and other protection to ensure the safety of operators.
● With temperature measurement display function and system clock display.
● Standard RS232 interface, can communicate with computer.
Specifications
Output voltage |
0-100kV optional |
Power distortion rate |
<3% |
Voltage increasing speed |
0.5~5kV/s adjustable |
Display |
Large LCD screen |
Electrode gap |
standard 2.5mm |
Boost times |
1~10 times |
Standing time |
15 min (adjustable) |
Boost interval |
5 minutes (adjustable) |
Booster capacity |
1.5kVA |
Measurement accuracy |
±3% |
Power input |
AC220V± 10%, 50Hz±1Hz |
Power |
200W |
Working temperature |
0-45℃ |
Humidity |
<75%RH |
Dimension |
585mm*390mm*410mm |
Weight |
43kg |
Accessories
GDOT-3B Tester | 1 set |
Oil cup | 3 pc |
Power cord | 1 pc |
Ground cable | 1 pc |
Spare fuse | 2 pcs |
Stirring nut | 2 pcs |
Standard gauge 2.5mm | 1 pc |
Tweezer | 1 pc |
Print paper | 1 rolls |
Allen wrench | 1 pc |
User’s guide | 1 pc |
Factory test report | 1 pc |
Product detail pictures:
Related Product Guide:
With our abundant experience and considerate products and services, we have been recognized to be a reputable supplier for a lot of global consumers for OEM Best Voltage Testing Equipment Suppliers – GDOT-3B 100kV 3 Cups Insulation Oil Breakdown Voltage (BDV)Tester – HV Hipot , The product will supply to all over the world, such as: Malaysia, St. Petersburg, Orlando, We welcome an opportunity to do business with you and hope to have pleasure in attaching further details of our products. Excellent quality, competitive price, punctual delivery and dependable service can be guaranteed. For further inquires please do not hesitate to contact us.