-
GDOT-3C 80kV 3 Cups Insulation Oil Breakdown Voltage (BDV)Tester
GDOT-3C 80kV 3 Cups Insulation Oil Breakdown Voltage Tester is fully digital industrial instrument with microcomputer control. It has the features of high accuracy and strong anti-interference ability.
-
GDBR-P Transformer Load No-load and Capacity Tester
Measure transformer No-load current, No-load loss, short circuit voltage, short circuit loss and capacity.
Three meters testing methods. -
GDZRC-100U Transformer DC Winding Resistance Tester
Transformer DC winding resistance is a required test item for the factory test, installation, overhaul, change of tap switch, handover test and preventive test of power department.
-
GDZRC-50U DC Winding Resistance Tester
GDZRC-50U DC Winding Resistance Tester is designed to measure DC resistance of inductive devices, such as transformers and power inductors.
-
GDZRC-40U (GDZRC-50U) DC Winding Resistance Tester
GDZRC-40U (GDZRC-50U) DC Winding Resistance Tester is designed to measure DC resistance of inductive devices, such as transformers and power inductors.
-
GDZRC-40A Series DC Winding Resistance Tester
GDZRC series DC winding resistance tester is designed to measure DC resistance of inductive devices, such as transformers and power inductors. It has the features of fast measurement, small size and high accuracy of measurement,which is ideal equipment of measuring transformer winding and DC resistance of big power inductance equipment.
-
GDZRC-20A DC Winding Resistance Tester
GDZRC series DC winding resistance tester is designed to measure DC resistance of inductive devices, such as transformers and power inductors.
It has the features of fast measurement, small size and high accuracy of measurement,which is ideal equipment of measuring transformer winding and DC resistance of big power inductance equipment. -
GDZRC Series DC Winding Resistance Tester (GDZRC-10A)
GDZRC-10A
GDZRC series DC winding resistance tester is designed to measure DC resistance of inductive devices, such as transformers and power inductors.
It has the features of fast measurement, small size and high accuracy of measurement,which is ideal equipment of measuring transformer winding and DC resistance of big power inductance equipment. -
GD6900 Capacitance and Dissipation Factor Tester
GD6900 measures the capacitance and dielectric loss factor (tgδ) of high voltage electric equipment. It is integrated structure, built-in dielectric loss test bridge, variable frequency adjustable power supply, boosting transformer and SF6 standard capacitor.
-
GDCL-V 20kV/10kA Impulse Combination Wave Test System Technical Solution
The equipment is according to combination wave testing requirement of the low-voltage power distribution system SPD II product, enable to generate impulse voltage (1.2/50μs) and impulse current (8/20μs), is used for grade III test and limiting voltage test of SPD and components.
-
Impulse Voltage Test System – High Voltage Test Instruments
GDCY series Impulse Voltage Generator can produce a wide range of voltage and energy to simulate waveform such as lightning impulse, lightning clipped wave, switching impulse and so on, enable to carry out various forms of impulse test for high voltage power equipment, cooperate with steepening device can carry out steep wave test on the insulator (insulator string).
-
GDCY-20B 20kV Impulse Voltage Tester (Basic Type)
GDCY-20B Programmable Automatic Impulse Voltage Tester is mainly based on TB/T 2653, GB/T 17627, GB/T 16927, GB14048, GB7251, GB/T 16935, IEC 61730, GB4706, GB3048, JB/T 7083 and other standard requirements.