GDUP-3000 Pure Sine Wave AC Power Supply

GDUP-3000 Pure Sine Wave AC Power Supply

Brief Description:

The GDUP-3000 is a versatile portable pure sine wave on-site AC test power supply. Also known as on-site AC and DC test power supply, AC and DC emergency power supply, field test power supply, mobile test power supply.


Product Detail

Product Tags

General information

The GDUP-3000 is a versatile portable pure sine wave on-site AC test power supply. Also known as on-site AC and DC test power supply, AC and DC emergency power supply, field test power supply, mobile test power supply. It has a safe power lithium-ion battery and efficient SPWM inverter conversion technology, with light weight, small size, long life and high capacity.

Application

Widely used in outdoor equipment such as power equipment emergency repair, power field test, mobile office, medical rescue, fire emergency rescue, environmental protection, emergency communication support, and power storage backup. It also provides a safe and reliable power source for instruments in the laboratory or in the field. 

Main Application

1. 220V/50Hz pure sine wave AC output
2. Can customize 110V, 60Hz output (export to Japan and the European Union)
3. 12V/10A DC output, 5V/2A-USB dual port output;
4. 24V/20A DC output;
5. LED emergency lighting;
6. Intelligent display, display battery digital power, input and output power and remaining working time;
7. Car charger, solar charging (optional)

Features 

● Built-in large-capacity polymer lithium battery, large capacity, extremely safe charging and discharging, no burning, no explosion.
● More than 1000 charge and discharge cycles.
● Work well within -20 ℃ ~ +50 ℃.
● High performance, no pollution, environmental-friendly.
● Small self-discharge: at room temperature for one-month, self-discharge less than 5%.
● With DC 5, 12, 24V output, AC 110V/220V output.
● It has cascading output function, which can realize automatic switching between main and auxiliary power sources, and extend the power supply time through multi-stage cascading.
● Large size LCD screen, eye-catching display voltage, current and other parameters.
● AC pure sine wave output with strong load capacity.
● It has automatic protection functions such as overcharge, over discharge, overload, overheat and short circuit.
● Smaller, lighter and stronger: the battery of the same capacity is 50% less than the weight of lead acid. Under the same load-bearing capacity, the floor space is only about 30% of the lead-acid battery.
● Configure a special backpack, easy to carry.
● The battery capacity retention rate stored for 12 months is ≥80.
● Protection level of battery: IP56.

Specification

Model

GDUP-3000        

Continuous output power

3000W

Peak power

6000W

Output voltage

 AC pure sine wave 220V/50Hz or AC 110V/60Hz DC 12V10A 5V2A 24V20A 51.8V50A 5V2A

Battery model

18650-22P14S (3.7V 2600mAh)

Capacity

51.8V 57.2AH

Service life

70%@1000 cycle

Charging time

5~6 hours (internal charger 58.8V 10A)

Protection

Over-voltage, over-temperature, over-load, AC short circuit, auto recovery

Work condition

-20℃~ 60℃

Cooling method

Fan forced cooling

Size

L515.5*W434.5*H270 (mm)

Material of shell

Anti-shock ABS

Weight

33kg

Test

No

Test item

Test conditions

Check item

 

1

Altitude test

1. Pressure ≤11.6Kpa, T =20±5℃

2. No package, no electricity

1. Appearance

2. Performance of power supply

 

2

Temperature test

Temperature between 40±2℃ and 75±2℃

The test is repeated for 10 times

Power on for 30 minutes.

1. Appearance

2. Performance of power supply

 

 

 

 

    3

Vibration test

 Amplitude: 1.52mm

Scanning frequency range: 5~10Hz, scanning speed: about 10m2/ S3,

Scanning frequency range: 0~200Hz, scanning speed: about 3m2/ S3,

Scanning frequency range: 200~500Hz, scanning speed: about 1m2/ S3,

Every vibration test lasts for 20 minutes. The vibration happens from all directions of X, Y and Z axis. The appearance remains intact, the product can pass all functional tests, and text on the label is clear, as well as function instructions. The product has no vibration and no noise; The screw is firmly fastened without sliding.

1. Appearance

2. Performance of power supply


  • Previous:
  • Next:

  • Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us