BISA Broadband Impedance Spectrum Analyzer | Portable Cable Fault Locator & Non-Destructive Cable Defect Analyzer

BISA Broadband Impedance Spectrum Analyzer | Portable Cable Fault Locator & Non-Destructive Cable Defect Analyzer

Brief Description:

BISA Broadband Impedance Spectrum Analyzer is a compact and portable device for diagnosing local cable conditions and locating defects. Whether in a laboratory environment or in a complex on-site electromagnetic environment, the instrument can complete tests quickly and non-destructively with extremely high accuracy, significantly reducing power outage time.


Product Detail

Product Tags

Features

• Accurately locate defects and faults such as moisture ingress, high resistance, mechanical damage, localized aging, open circuit, short circuit, etc.
• Suitable for testing various types of cables including low-voltage distribution cables, unarmored cables, transmission cables, and low-voltage DC cables.
• Three display modes: step response, impulse response, and pulse amplitude; multi-dimensional presentation of fault characteristics.
• Feature analysis and contrast analysis histograms provide intuitive status results.
• Non-destructive, non-invasive, non-destructive low-voltage testing technology.
• Wide frequency and low-attenuation technology significantly improves early defect recognition resolution.
• Intuitive software interface, easy analysis.
• Parameters can be set for different situations. Achieve one-click detection and positioning.
• Can detect minor defects caused by moisture, overheating, external damage, chemicals, radiation, water trees, etc.
• Achieve non-destructive testing, with a long effective testing distance and high positioning accuracy.
• High testing speed, with a single test taking no more than 1 minute, ensuring efficient maintenance.
• Can perform cable distance measurement and intermediate joint defect location, and can also effectively inspect cables without specific information.
• The product is portable, sturdy and durable, and has a long battery life.

Specifications
Frequency range 100kHz~100MHz 9kHz~1GHz
Max. Output power 0dBm ±10dBm
Dynamic range 85db 115db
Number of measurement ports 1/3 1/3
Frequency accuracy 2ppm 7ppm
Test speed

 

1000 points/seconds 10000 points/seconds
Max.number of sweep points 10000 points 50000 points
Cable length 10m~100km 10m~200km
Positioning accuracy ±0.5% of total length ±0.1%±10cm of total length
Tested type  

Shielded cable

Shielded cables

Unshielded cables

Special low-voltage cables

Cable outer sheath

Display Method - Raw Data Reflection coefficient wave impedance Reflection coefficient wave impedance
Display Method - Results Analysis Impulse response

Pulse amplitude

Impulse response

Pulse amplitude

Step response

Analysis functions Feature analysis Feature analysis

Comparative analysis

Bandwidth adjustment analysis

Power supply Battery AC power supply
Operating temperature -15°C to +50°C
Operating humidity <80% (relative humidity)

 