GD-3134D+GD-2134L UHV Cable Sheath Fault Locator

GD-3134D+GD-2134L UHV Cable Sheath Fault Locator

Brief Description:

GD-3134D UHV cable sheath fault locator is an intelligent instrument with innovative features and high performance that integrates computer technology and digital signal processing technology. The UHV cable sheath fault locator can measure the resistance current in the faulty cable in the wellbore through the current sensor and locate the cable fault point in sections. For cables laid on cable supports in large quantities in cable tunnels, the DC voltage can also be measured by high-voltage probes to determine the fault point.

The UHV cable sheath fault locator needs to be used in conjunction with the GD-2134L UHV cable sheath fault signal generator, which can provide high-voltage pulse signal source for the fault location of the UHV cable sheath, to complete the precise location of the UHV cable sheath grounding fault.


Product Detail

Product Tags

Features

 

GD-3134D UHV cable sheath fault locator 

•Three fixed-point modes, suitable for different fault types.

  1. Step-voltage pinpointing mode: indicate the fault point directly and quickly find the fault point.
  2. Fault current pinpointing mode: Quickly find the fault point by measurement the resistance current in the fault cable.
  3. HV rod pinpointing mode: Measure the DC voltage in the fault cable to find the fault point.

• High sensitivity and large response range.

•Adopting digital signal processing technology, the signal waveform is directly displayed, and the anti-interference ability is strong.

• Automatic zero adjustment to offset the influence of ground potential changes.

•Built-in large-capacity lithium-ion battery pack, automatic shutdown under voltage, and automatic shutdown after long-term no operation.

•Solid case, light weight and portable

GD-2134L UHV cable sheath fault signal generator

•Built-in high-voltage constant current source, the output voltage and current are continuously adjustable, allowing the output to operate in a long-term short circuit.

• It has multiple safety protection functions such as grounding lockout and high-voltage zero-position start.

•It can provide a signal source for the pinpointing of the fault on the sheath of the ultra-high voltage cable.

• The transmitter can be powered by mains electricity or a generator, and the sensor and receiver can be powered by dry batteries.

Specifications

GD-3134D UHV cable sheath fault locator

Mode

Accessory

Accuracy

Max. Sensitivity

Max. Input Range

Display

Step-Voltage Pinpoint

Step Voltage Probe

1%(±0.1mV)

0.1mV

±300V

Signal Waveform, Fault Point Direction

Fault Current Pinpoint

Current Sensor

1%(±1mA)

1mA

±1A

Signal Waveform, Fault Current Value

HV Probe Rod Pinpoint

Step Voltage Rod

<1%(10V-10kV)

1V(10-1kV)

10V(1kV-10kV)

±10kV

DC Voltage

Others

Built-in

18650 Lithium Battery, Standard 3.7V, 6.8Ah

Work Condition

Temperature :-10℃-40℃; Humidity 10-90%Rh; Altitude <4500m

Dimension and Weight

Dimension: 220mm×125mm×55mm; Weight: 0.9kg.

GD-2134L UHV cable sheath fault signal generator

Power supply

AC 220V, can be connected to a generator (output power ≥ 1500W)

Pinpoint Accuracy

0.2m

Output frequency

1Hz

Open circuit voltage

Fundamental effective value 0~2800V,

(Pulsating DC, peak value 8kV, equivalent to the phase voltage peak value of 10kV line)

Shirt circuit DC

Effective value of fundamental wave 0~35mA

 (Pulsating DC, peak100mA)

Work Condition

Temperature: -10℃-40℃; Humidity 10-90%Rh; Altitude <4500m

Max. Power

900W

Dimension and Weight

Dimension: 417mmx234mmx318mm  

Weight: 16.8kg

 