China High Quality Capacitance Is Measured By Factory – AC Dielectric Test Equipment with manual control unit GDYD-D – HV Hipot
China High Quality Capacitance Is Measured By Factory – AC Dielectric Test Equipment with manual control unit GDYD-D – HV Hipot Detail:
Application
Features
● Digital (Pointe) display panel mounted controls & indicators with easy-to-read legend.
● Monitoring high voltage side voltage, low voltage side current and indicator of zero, power, working start, timing.
● Over-current protection, zero-starting protection, sound, and light alarm.
● Continuously variable output from zero to full voltage.
● Adjustable over current protection, with trip levels variable from 10 to 110%.
● With new type time relay, time range is wider (1S ~ 99H).
● Using the latest current relay, more accurate and reliable.
● Light weight, small size, easy to move.
Technical Specifications
● Input voltage: AC 220V or 380V
● Output voltage of control unit: AC 0-250V or 0-430V
● Output current of control unit:0-5/10/15/50A(customized)
● Capacity: 0-3/5/10/15/20/30/50/100kVA(customized)
● Output voltage of HV unit: 0-50/100/150/200kV(customized)
● Output current of HV unit: 0-50/100/150/200/500/1000/2000mA(customized)
● Timing: 0-9999s
● Environmental temperature: -20℃–50℃
● Voltage accuracy: ≤ 1.5%±1digit (F.S)
● Current accuracy: ≤ 1.5%±1digit (F.S)
Other accessories for option
We can customize different ratings based on different requirement. Welcome to consult with us!
Product detail pictures:
Related Product Guide:
We've been commitment to offer the competitive rate ,outstanding merchandise good quality, too as fast delivery for China High Quality Capacitance Is Measured By Factory – AC Dielectric Test Equipment with manual control unit GDYD-D – HV Hipot , The product will supply to all over the world, such as: Australia, Sheffield, Florida, As operation principle is "be market-oriented , good faith as principle, win-win as objective", holding on "customer first, quality assurance, service first" as our purpose, dedicated to provide the original quality, create excellence service , we won the praise and trust in the industry of auto parts. In the future, We will provide quality product and excellent service in return to our customers , welcome any suggestions and feedback from all over the world.
By Joanne from Myanmar - 2018.10.01 14:14
In China, we have purchased many times, this time is the most successful and most satisfactory, a sincere and realiable Chinese manufacturer!
By Bella from Italy - 2017.06.22 12:49