China High Quality Capacitor In Transformer Supplier – Partial Discharge Test System GDYT series – HV Hipot
China High Quality Capacitor In Transformer Supplier – Partial Discharge Test System GDYT series – HV Hipot Detail:
GDYT is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It widely used in electrical manufacturing, power operation departments, research institutes and universities.
It includes below components
1. Hipot Test Control Unit GDYD
2. PD-free Gas type transformer YDQW
3. Coupling capacitor
4. Protective resistor
5. Isolation filter LBQ
6. Partial discharge detector
Features
● Advanced PD-free epoxy insulating tube, small partial discharge capacity.
● Low impedance voltage, better than national standard.
● Automatic control technology, good anti-interference performance.
● Rapid electronic protection, high reliability.
Specifications
● Rated Capacity (KVA) : 5~5500
● High Voltage (KV): 50~250
● Low Voltage (KV): 0.22/0.38~0.38/0.6~0.6/3~3/6/10
● Top cover(mm): accordance with specific conditions
| Model | Rated Capacity | High Voltage | Low Voltage | Top cover OD x Height | Weight |
| (KVA) | (KV) | (KV) | (mm) | (KG) | |
| GDYT-5/50 | 5 | 50 | 0.22/0.38 | 320×450 | 42 |
| GDYT-50/50 | 50 | 50 | 0.22/0.38 | 850×945 | 360 |
| GDYT-10/100 | 10 | 100 | 0.22/0.38 | 570×725 | 150 |
| GDYT-50/100 | 50 | 100 | 0.22/0.38 | 850×1000 | 400 |
| GDYT-100/100 | 100 | 100 | 0.22/0.38 | 850×1000 | 800 |
| GDYT-15/150 | 15 | 150 | 0.22/0.38 | 1165×1400 | 500 |
| GDYT-75/150 | 75 | 150 | 0.22/0.38 | 1350×1570 | 1100 |
| GDYT-150/150 | 150 | 150 | 0.38/0.6 | 1350×1570 | 1400 |
| GDYT-20/200 | 20 | 200 | 0.22/0.38 | 1165×1850 | 760 |
| GDYT-100/200 | 100 | 200 | 0.22/0.38 | 1450×1950 | 1800 |
| GDYT-200/200 | 200 | 200 | 0.38/0.6 | 1800×1950 | 3100 |
| GDYT-25/250 | 25 | 250 | 0.22/0.38 | 1250×2200 | 1250 |
| GDYT-150/250 | 150 | 250 | 0.38/0.6 | 1450×2200 | 1900 |
| GDYT-250/250 | 250 | 250 | 0.38/0.6 | 2000×2300 | 3100 |
| GDYT-500/250 | 500 | 250 | 3/6 | 200×2600 | 5800 |
| GDYT-1000/250 | 1000 | 250 | 3/6 | 2200×2600 | 8200 |
Product detail pictures:
Related Product Guide:
We know that we only thrive if we can guarantee our combined price competiveness and quality advantageous at the same time for China High Quality Capacitor In Transformer Supplier – Partial Discharge Test System GDYT series – HV Hipot , The product will supply to all over the world, such as: New Delhi, Mexico, Yemen, we rely on own advantages to build a mutual-benefit commerce mechanism with our cooperative partners. As a result, we've gained a global sales network reaching the Middle East, Turkey, Malaysia and Vietnamese.