Being supported by an innovative and experienced IT team, we could present technical support on pre-sales & after-sales service for High Voltage Capacitor Price, Vlf Test Kit, Transformer Tester, We are confident to make great achievements in the future. We are looking forward to becoming one of your most reliable suppliers.
China High Quality Capacitor Setting On Multimeter Manufacturers – AC DC High Voltage Divider – HV Hipot Detail:

GDFR-C1 series AC/DC Voltage Meter

GDFR-C1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. It consists of voltage divider and measurement instrument.

Features

● Balance type equal potential shield structure.
● Fully-sealed insulation cylinder with internal excellent components.
● High accuracy and linearity, good stability and anti-interference ability.
● The voltage ratio can be customized, suitable for calibration.
● Upside down is forbidden when installation.

Technical Specifications

Model No. GDFR-C1-50 GDFR-C1-100 GDFR-C1-150 GDFR-C1-200 GDFR-C1-300 GDFR-C1-400
Voltage(kV) 50 100 150 200 300 400
DC frequency (Hz) <2
AC frequency (Hz) 30-300
Accuracy AC: 1.5%/DC: 1.0%
Accuracy for option (G type) AC: 1.0%/DC: 0.5% –
Accuracy for option (H type) AC: 0.5%/DC: 0.5% – –
Impedance
(MΩ)
650 1280 2000 2640 4000 5360
Capacitance
(pF)
320 250 400 / 160 300 200 300
Voltage ratio 1000:1 or 10000:1(or customized)
Dimension
(mm)
150×150 160×160 350×350 800×800 1000×1000
Cable impedance(Ω) 50 / 75
Range 1. Low range: 0-20kV
2. High range: 20kV-rated voltage
3. Low range: 0-200kV
4. High range:200kV-rated voltage
Cable length(m) 3 4 6 6 10 10
Weight(kg) 5.5 9.5 12.5 14.5 27 40
Packing Medium Polyurethane foaming agent
Operation temperature 0℃-45℃
Relative humidity <85%RH, no condensation
Altitude <1500m (or customized)
Use condition Indoor use or outdoor use in Sunny day

Product detail pictures:

China High Quality Capacitor Setting On Multimeter Manufacturers –  AC DC High Voltage Divider – HV Hipot detail pictures

China High Quality Capacitor Setting On Multimeter Manufacturers –  AC DC High Voltage Divider – HV Hipot detail pictures

China High Quality Capacitor Setting On Multimeter Manufacturers –  AC DC High Voltage Divider – HV Hipot detail pictures


Related Product Guide:

Our purpose is to fulfill our clients by offering golden company, great price and premium quality for China High Quality Capacitor Setting On Multimeter Manufacturers – AC DC High Voltage Divider – HV Hipot , The product will supply to all over the world, such as: Malta, Turin, Cannes, With a team of experienced and knowledgeable personnel, our market covers South America, the USA, the Mid East, and North Africa. Many customers have become our friends after good cooperation with us. If you have the requirement for any of our goods, make sure you contact us now. We're looking forward to hearing from you soon.
  • As a veteran of this industry, we can say that the company can be a leader in the industry, select them is right.
    5 Stars By Alexandra from Canada - 2018.05.15 10:52
    The customer service staff is very patient and has a positive and progressive attitude to our interest, so that we can have a comprehensive understanding of the product and finally we reached an agreement, thanks!
    5 Stars By Alan from Chicago - 2018.02.08 16:45

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us