GDDO-20C AC/DC Electric Meter Calibration Device is used to detect basic error of various power frequency electric instruments in power systems, including voltmeter, ammeter, wattmeter, ohmmeter, single phase & three phase AC energy meters (optional) and basic error of DC volt-meter and ammeter.
For meter’s part, it takes high precision power frequency AC collector as core technology, which consists of digital signal processor (DSP) and 16-digit high speed analog-digital converter; For signal source, it uses DSP and 16-digit high speed analog-digital converter to form signal source that produces sine wave signal and distortion wave signal.
Features
● Accuracy class of 0.05. When AC voltage, AC current and active power are measured, the device is equipped with a digital/frequency converter (DFC) with a working frequency higher than 60kHz and multiple current ranges, so high accuracy is guaranteed.
● The distortion wave of 2~31 times, number, times and amplitude of harmonics, and phase of harmonic to fundamental wave can be all programmed.
● 6.5-inch color TFT LCD screen, clear and bright display.
● With RS232 communication port.
● With a large capacity non-volatile memory, can store test results of 300 meters under test, support data view and data upload function.
● With good reliability, easy to operate.
Specification
|
Power frequency AC output |
|
|
Voltage range (V) |
50, 100, 200, 400, 600 (800V is optional), Max. output capacity 20VA |
|
Current range (A) |
0.5, 1, 2.5, 5, 10, 20, Max. output capacity 20VA |
|
Voltage adjustment range |
0~130%, fineness adjustment 5*10 |
|
Current adjustment range |
0~130%, fineness adjustment 5*10 |
|
Accuracy of voltage, current, active power and energy |
0.05% |
|
Accuracy of reactive power and energy |
0.1% |
|
Phase accuracy of current to phase voltage |
0.05° |
|
Frequency |
Adjustment range: 45~65Hz, Fineness adjustment: 0.001Hz Setting value accuracy: 0.01Hz |
|
Phase |
Adjustment range: 0~359.99° Fineness adjustment: 0.01° Setting value accuracy: 0.05° |
|
Distortion degree of voltage and current output waveform |
≤0.3% |
|
Stability of voltage, current and power output |
≤0.01%/60s (peak-to-peak value) |
|
Harmonics |
2~31 times Amplitude: 0~20% Phase fineness: 0.01°*N (“N” refers to harmonic order) |
|
DC output |
|
|
Voltage range (V) |
0.075, 75, 150, 300, 500, 1000, Max. output capacity 20W |
|
Current range (A) |
0.5, 1, 2.5, 5, 10, 20, Max. output capacity 20W |
|
Adjustment range of voltage and current |
0~120% (not including 1000V), fineness adjustment 5*10 |
|
Stability of voltage and current output |
≤0.01%/60s (peak-to-peak value) |
|
Accuracy of voltage setting value |
0.05% |
|
Accuracy of current setting value |
0.1% |
|
Accuracy at 75mV output (Load ≥5Ω) |
0.1% |
|
General parameters |
|
|
Power supply |
Single phase 220V±10%, 50Hz±5% |
|
Use conditions |
20℃±10℃, ≤85%RH |
|
Dimension |
460*460*175mm |
|
Weight |
About 20kg |
Packing List
| Main unit | 1 set |
| Aluminum alloy box | 1 set |
| Power cord | 1 pc |
| Test line with connector | 1 pc |
| Test line (DC 75mV) | 1 pc |
| Test line for electric energy pulse | 1 pc |
| Communication cable | 1 pc |
| Photoelectric collector | 1 pc |
| User’s guide | 1 copy |
| Factory test report | 1 copy |
Product detail pictures:
Related Product Guide:
We've been committed to offering easy,time-saving and money-saving one-stop purchasing support of consumer for China High Quality Energy meter testing Factories – GDDO-20C AC/DC Electric Meter Calibration Device – HV Hipot , The product will supply to all over the world, such as: Monaco, Jeddah, Florence, All styles appear on our website are for customizing. We meet up to personal requirements with all products of your very own styles. Our concept is to help presenting the confidence of each buyers with the offering of our most sincere service, and the right product.