China High Quality Hv Pulse Generator Manufacturers – Impulse Voltage Test System – HV Hipot
China High Quality Hv Pulse Generator Manufacturers – Impulse Voltage Test System – HV Hipot Detail:
Features
● Complete equipment and wide voltage levels in the whole set of device.
● Small electric inductance in the return circuit of the impulse voltage generator, A band-stop filtering is adopted so that a standard impulse wave is still generated even under a large capacity load, and large load capacity.
● Large in voltage utilization coefficient.
● Convenient in wave adjustment, simple in operation, excellent in synchronization performance and reliable in motion.
● An automatic control technique is adopted in the constant-current charge, which is high automation and strong anti-interference capacity.
● A digital measurement and analysis system for the impulse test date are adopted, which increase the technical level and the efficiency of the impulse voltage tests.
Specifications
| Impulse voltage grade | 100kV-7200kV |
| Standard lightning wave | 1.2±30%/50±20%µS |
| Peak oscillation | <5% |
| Standard switching wave | 250±20%/2500±60%µS |
| Virtual front time of oscillating lightning wave | ≤15µS |
| Virtual front time of oscillating switching wave and virtual front time of oscillating switching impulse wave |
15µS-1mS |
| The minimum output voltage | ≥10%Un |
| Charging voltage instability | <±1% |
| Synchronizing range | ≥20% |
| Synchronous discharge error rate | <2% |
| Ignition range | 10%~100% |
| Working time | ≥70%UN Discontinuous work (charge-discharge 300s/time) <70%nn Continuous work (charge-discharge 120s/time) |
| Generator efficiency: lightning wave (no load) | ≥90% |
| Time to chopping | 2~5µS |
Product detail pictures:
Related Product Guide:
We pursue the administration tenet of "Quality is exceptional, Assistance is supreme, Reputation is first", and will sincerely create and share success with all clients for China High Quality Hv Pulse Generator Manufacturers – Impulse Voltage Test System – HV Hipot , The product will supply to all over the world, such as: United States, British, Luxembourg, We focus on providing service for our clients as a key element in strengthening our long-term relationships. Our continual availability of high grade products in combination with our excellent pre-sale and after-sales service ensures strong competitiveness in an increasingly globalized market.