China High Quality Sf6 Gasdetector Factory – GDWG-IV SF6 Gas Leak Detector(IR series) – HV Hipot
China High Quality Sf6 Gasdetector Factory – GDWG-IV SF6 Gas Leak Detector(IR series) – HV Hipot Detail:


Product Description
GDWG-IV SF6 Gas Leak Detector is infrared red type leak detector(NDIR technology). It is color OLED display and real-time shows SF6 concentration. It rapidly detect SF6 breaker, GIS leakage point and yearly leakage rate qualitatively and quantitatively. It’s a good device suitable for power supply department, installation and overhaul unit, power test institute.
Application
● High Voltage Switch Equipment
● Rotor vane of helicopter
● Gas transmission system
● To detect fire extinguisher
● Ventilation efficiency research of Buildings
● To detect danger
Advantages
● No radiation.
● No need to replace high pressure high pure argon gas regularly.
● No need to approach high pressure gas.
● No need to replace sensors regularly, cost-effective.
● Stable performance, low maintenance cost. No need to make linear calibration every year.
● No affect by moisture and environment pollution.
● High sensitivity, up to 0.01ppmv.
● When serious leakage or the SF6 gas concentration is up to 100%, it will not be polluted or damaged.
Features
● OLED display.
● Built-in Lithium battery.
● User-defined alarm with sound and light.
● High sensitivity and good stability.
● Fast measurement speed, time is up to 3s.
● Temperature and pressure compensation.
● Only response for SF6 gas, not for other gas.
● Small size, easy to carry, suitable for on-site working.
● With gasbag non-slip straps, more comfortable to carry.
● Data storage up to 8000groups.
● Super-light aluminum with full shielding shell.
● External package uses engineering plastic, with water-proof, dust-proof.
Specifications
● Measuring principle: Non-dispersive infrared sensor (NDIR)
● Measuring range: 0-5000ppm SF6
● Accuracy: ±2%FS(0-1000ppm)
● Repeatability error: ≤±1%
● Sensitivity: 0.01ppmv
● Response time: ≤3s
● Recovery time: ≤5s
● Stability: ≤±20ppm, more than 1000hours
● Zero shift: ≤±1%(F.S/year)
● Linear error: ≤±1%
● Storage temperature: -20~+60℃
● Operation temperature: -20~+50℃
● Sampling mode: Built-in electromagnetic diaphragm pump, automatic slot-in type, flow up to 1L/min.
● Working voltage: 220VAC±10%,50Hz Or Built-in Li-battery.
● Dimension: 140×235×83mm
● Weight: about 1.5kg
Accessories
| CT/PT Tester | 1piece |
| Test Lead | 1set |
| Earth cable | 1piece |
| Power cord | 1piece |
| 2A fuse | 2pcs |
| User’s guide | 1copy |
| Factory test report | 1copy |

Product detail pictures:
Related Product Guide:
We're proud from the higher client fulfillment and wide acceptance due to our persistent pursuit of high quality both on product and service for China High Quality Sf6 Gasdetector Factory – GDWG-IV SF6 Gas Leak Detector(IR series) – HV Hipot , The product will supply to all over the world, such as: azerbaijan, Los Angeles, Saudi Arabia, We've got a dedicated and aggressive sales team, and many branches, catering to our customers. We are looking for long-term business partnerships, and ensure our suppliers that they will absolutely benefit in both short and long run.
The company keeps to the operation concept "scientific management, high quality and efficiency primacy, customer supreme", we have always maintained business cooperation. Work with you,we feel easy!





