  • OEM Best Digital Insulation resistance meter Factories –  GDHX-9700 Phase Detector – HV Hipot

    OEM Best Digital Insulation resistance meter Factories – GDHX-9700 Phase Detector – HV Hipot

    General Information GDHX-9700 Phase Detector is mainly used in electric power lines, phase, and phase sequence calibration in substation, with main functions including electrical inspection, phase calibration and phase sequence measurement. It uses double shielding and brand-new digital circuits, with strong anti-interference, accorded with EMC standards, suitable for various electromagnetic interference situations. The high voltage phase signal of measured lead will be transmitted directly after treatment, the handset will receive and make phase comparison, determine the results after phase detection, real-time display phase angle difference and vector. It uses wireless transmission technology, safe and reliable, fast, and accurate, suitable for using at different voltage levels (10...
  • OEM Best How To Test Circuit Breaker Manufacturers –  GMDL-02A HV Circuit Breaker Analog Device – HV Hipot

    OEM Best How To Test Circuit Breaker Manufacturers – GMDL-02A HV Circuit Breaker Analog Device – HV Hipot

    General Information GMDL-02A high-voltage circuit breaker simulation device is manufactured using the principles of large-scale field programmable gate arrays, power electronic devices with protection, etc. The open coil is designed according to an independent loop, which can simulate the three-phase and split-phase operation of the voltage level of 6-110KV. The action behavior of the single open coil circuit breaker is suitable for the selection of power systems, industrial and mining enterprises, scientific research institutes, professional colleges, and protection manufacturers. It is used as a substitute for actual circuit breakers in the transmission test of the entire system of relay protection and automatic devices with switches. The action is accurate, reliable, and the numbe...
  • China High Quality relay tester made in china Factories –  GDJB-6000D Smart Substation Relay Protection Test System – HV Hipot

    China High Quality relay tester made in china Factories – GDJB-6000D Smart Substation Relay Protection Test System – HV Hipot

    GDJB-6000D is equipped with high-performance power amplifier and based on the powerful PowerPC+X86 platform. It adopts modular design and have powerful functions, high precision, small size and light weight features. It can test the function and performance of merging unit, relay protection device, measurement and control device, intelligent terminals etc. Very suitable for power plants, substations, various scientific research units and equipment manufacturing enterprises.  Features ● Smart Test Module Intelligent test template editing is supported. Test items can be randomly added during the test process and saved as reusable test project files to improve the test efficiency in the final stage of inspection and elimination. ● Automatic testing With on-site protection and digital pr...
  • China High Quality ultrasonic detector Manufacturers –  GD-610B Insulator Faults Detector – HV Hipot

    China High Quality ultrasonic detector Manufacturers – GD-610B Insulator Faults Detector – HV Hipot

    General Information In High Voltage Distribution Network, it usually cause the faults of flashover, grounding or porcelain explosion because of insulators degradation. So it is important to detect and eliminate the faults of insulators, to ensure safe running of transmission and distribution line. GD-610B Insulator Faults Detector is used to locate insulator faults in power plants and substation transmission lines under uninterrupted power state. It can also be used in partial discharge detection of electrical equipment, corona discharge detection, high voltage switch discharge detection and so on. Applications The electric power, agricultural power, water conservancy and other departments in all regions that have power transmission lines, as well as scientific research units of i...
  • OEM Best insulation oil acidity test Factory –  GDC-9560B Power System Insulation Oil Gas Chromatograph Analyzer – HV Hipot

    OEM Best insulation oil acidity test Factory – GDC-9560B Power System Insulation Oil Gas Chromatograph Analyzer – HV Hipot

    General Information  GDC-9560B Gas Chromatograph Analyzer is to analyze the gas content of insulation oil by gas chromatographic method. It is effective to judge if the running equipment has potential fault like over-heat, discharge or not, to ensure the safety of power grid. It is also necessary to be used for manufacturer of gas/oil equipment to inspect their equipment before leaving factory. Gas chromatography analysis technology is a technique for separation and analysis of multi-component mixtures. It mainly uses the difference of boiling point, polarity and adsorption coefficient of each component in the sample in the column, so that the components are separated in the column, and the separated components are qualitatively and quantitatively analyzed. The gas chromatograph uses...
  • China High Quality Ct Tester Manufacturer –  GDHG-201P CT/PT Analyzer – HV Hipot

    China High Quality Ct Tester Manufacturer – GDHG-201P CT/PT Analyzer – HV Hipot

    Features ● Full function and can satisfy all kinds of CT (protection CT, measuring CT, TP) test requirements, such as excitation characteristic test, turn ratio, polarity, secondary winding resistance, secondary burden, ratio error, angular difference and etc. Also can used to test excitation characteristic, turn ratio, polarity, secondary winding resistance, ratio error, angular difference and etc of all kinds of PT. ● Field verification of CT does not require standard current transformers, current injector, load bank, voltage regulating controller and large current cables. Very simple test wiring and operation are used to realize the current transformer verification, which greatly reduces the work intensity and improves the work efficiency, and facilitates the field verification of...
  • OEM Best Cable Testing Manufacturers –  GD-2134A Cable Identifier – HV Hipot

    OEM Best Cable Testing Manufacturers – GD-2134A Cable Identifier – HV Hipot

    The purpose of the cable identifier is to accurately identify one of the target cables from multiple cables and avoid serious accidents caused by wrong sawing of live cables. Cable identification starts from the operation of both ends of the cable, it must be ensured that the double number on both ends of the cable is accurate. GD-2134A Cable Identifier is only suitable for on-site identification of de-energized cables. It is strictly forbidden to connect the cable identifier to the running power cable! Features ● Handheld receiver automatically identify and display the results to ensure that the results of cable identification are 100% accurate. Light weight and powerful, easy to carry. ● Suitable for on-site identification of de-energized cables. ● Both transmitter and handheld re...
  • China High Quality relay testing companies Supplier –  GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot

    China High Quality relay testing companies Supplier – GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot

    Features ● Output up to 6-phase voltage 6-phase current, which can be combined to realize conventional 4-phase voltage 3-phase current type, 6-phase voltage type, 6-phase current type, and 12-phase output mode. ● High-performance embedded industrial control computer and 8.4-inch large-screen high-resolution color TFT liquid crystal display, which can provide rich and intuitive information, including the current working status of the device, next working tips and various help information; ● The output uses a high-fidelity, high-reliability modular linear power amplifier instead of a switch-type power amplifier for superior performance. It will not generate high and medium frequency interference to the test site, and it will ensure excellent waveform smoothing and accuracy from high cu...
  • OEM Best Power Cable Tracer Manufacturer –  GD-4136H Cable Fault Locating System  – HV Hipot

    OEM Best Power Cable Tracer Manufacturer – GD-4136H Cable Fault Locating System – HV Hipot

    GD4136H Cable Fault system is an important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables. The system contains below units: 1.GD-2131H Impulse Generator 2.GD-4132 Cable Fault Locator 3.GD-4133 Multi-pulse Cable Fault Detector 4.GD-4133S Multi-pulse Coupler 5.Other accessories GD-2131H Impulse Generator It’s used to generate HV impulse when using impulse flashover method to detect high impedance fault. Features ● Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased. ● If working together with GD-4133 Cable Fault Tester, there are two locating ways: a. Low vol...
  • China High Quality electrical relay testing Suppliers –  GDJB-6000D Smart Substation Relay Protection Test System – HV Hipot

    China High Quality electrical relay testing Suppliers – GDJB-6000D Smart Substation Relay Protection Test System – HV Hipot

    GDJB-6000D is equipped with high-performance power amplifier and based on the powerful PowerPC+X86 platform. It adopts modular design and have powerful functions, high precision, small size and light weight features. It can test the function and performance of merging unit, relay protection device, measurement and control device, intelligent terminals etc. Very suitable for power plants, substations, various scientific research units and equipment manufacturing enterprises.  Features ● Smart Test Module Intelligent test template editing is supported. Test items can be randomly added during the test process and saved as reusable test project files to improve the test efficiency in the final stage of inspection and elimination. ● Automatic testing With on-site protection and digital pr...
  • OEM Best omicron cmc Factories –  GDJB-6000M Smart Substation Relay Protection Test System – HV Hipot

    OEM Best omicron cmc Factories – GDJB-6000M Smart Substation Relay Protection Test System – HV Hipot

    GDJB-6000M Smart Substation Relay Protection Test System is a new generation of intelligent relay protection tester designed according to “Smart Substation Relay Protection Technical Specifications” and “Smart Substation Technical Guidelines”. It can not only realize the full function test of the optical digital protection device (IEC61850, smart digital station), but also carry out full function test on the traditional protection device (conventional station). GDJB-6000M is a portable new product independently developed through the use of technologies such as embedded real-time operating systems, high-performance embedded processors, and large-scale logic devices, combined with power field conditions and numerous power user experiences. It is widely applicable t...
  • China High Quality alat ukur megger Manufacturers –  GDCR3000 Digital Earth Resistance Tester – HV Hipot

    China High Quality alat ukur megger Manufacturers – GDCR3000 Digital Earth Resistance Tester – HV Hipot

    General Information GDCR3000 Digital Earth Resistance Tester is specially designed and manufactured for field measurement, adopting the latest digital and micro-processing technology, 3-pole or 2-pole method for earth resistance measurement, with a unique function of wire resistance verification, anti-interference capability and the ability to adapt to the environment, to ensure high precision, high stability and reliability for prolonged measure, which is widely used in electric power, telecommunications, meteorology, oil field, construction, lightning protection, industrial electrical equipment and other earth ground resistance measurement. Measurement range & Accuracy Measurement function Range Accuracy Resolution Earth resistance 0.01Ω~20Ω ±2%rdg ±3dgt (Auxiliary ear...