Featured

  • OEM Best laser test insulator Factory –  GDUD-PTM Ultrasonic Flaw Detector for Electrical Power Tower – HV Hipot

    OEM Best laser test insulator Factory – GDUD-PTM Ultrasonic Flaw Detector for Electrical Power Tower – HV Hipot

    Features ● TFT true color screen. ● Using leading embedded digital system technology, the electrical performance indicators of the instruments are designed and manufactured according to the standard EN 12668.1 – 2000. ● Advanced and safe lithium polymer battery and power management technology, automatic alarm and protection. The automatic standby screen saver can be set to make the equipment more energy-efficient and longer-lasting, and to ensure continuous and efficient flaw detection. ● Application software that integrates intelligent and powerful processing functions, direct-reading user interface and operation mode, or digital knob one-button operation mode. ● Large-capacity detection parameters preset channel, convenient for users to operate on different detection objects...
  • China High Quality Primary Current Injection Kit Factory –  GDKC-15 Series Circuit Breaker Analyzer 2020.12 – HV Hipot

    China High Quality Primary Current Injection Kit Factory – GDKC-15 Series Circuit Breaker Analyzer 2020.12 – HV Hipot

    General Information High voltage circuit breaker is one of the most important control equipment in the power system. GDKC-15 Series is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate, with high accuracy.  GDKC-15 Series   GDKC-15A GDKC-15B GDKC-15C GDKC-15D GDKC-15E GDKC-15F GDKC-15G GDKC-15H Metal contact 12 12 12 12 12 12 12 12 Closing resistance   6 6 6 6 6 6 6 Graphite contact       3 3 3 3 6 Double-ended grounding         3 3 3 6 Dynamic resistance(Pre-insertion resistor) 1 1 3 3   3 3 6 Static resistance 1 1 3 3   3 3 6 Ground resistance             3 6 Features ● It is suitable for the mechanical test of all types of SF6 switches, GIS combination appliances, vacuum switches and oil switches. ● Strong an...
  • China High Quality Advantages Of Current Injection Test Suppliers –  GDGK-501 DC Power Supply – HV Hipot

    China High Quality Advantages Of Current Injection Test Suppliers – GDGK-501 DC Power Supply – HV Hipot

    Features ● Using contact regulators to output voltage and rectify by rectifier bridge. ● The output voltage is continuous adjusted. ● Thermal cut-outs for short-circuit protectors at DC output. ● Small size, light weight. Specifications ● Input Voltage: AC220V±10%, 50Hz, single phase ● Capacity: 3kVA ● Output Voltage: AC 0-260V DC 0-360V ripple: 3% ● Output Current: 10A (continuous), 20A(short time) ● 24vdc, 48vdc, 110vdc, and 250vdc, 15A ● Maximum load current: 20A ● Accuracy: 1.5% of the range ● Temperature: -10℃-45℃, humidity: <80% ● Dimension: 440*340*240 mm ● Weight: 18kg Accessories Test Box 1 set Power cord 1 piece Ground wire 1 piece Test wire 6 pieces Manual 1 piece Factory test report 1 copy Packing list 1 copy
  • China High Quality Surge Wave Generator Manufacturers –  Impulse Voltage Test System – HV Hipot

    China High Quality Surge Wave Generator Manufacturers – Impulse Voltage Test System – HV Hipot

    Features ● Complete equipment and wide voltage levels in the whole set of device. ● Small electric inductance in the return circuit of the impulse voltage generator, A band-stop filtering is adopted so that a standard impulse wave is still generated even under a large capacity load, and large load capacity. ● Large in voltage utilization coefficient. ● Convenient in wave adjustment, simple in operation, excellent in synchronization performance and reliable in motion. ● An automatic control technique is adopted in the constant-current charge, which is high automation and strong anti-interference capacity. ● A digital measurement and analysis system for the impulse test date are adopted, which increase the technical level and the efficiency of the impulse voltage tests. Specifications ...
  • China High Quality Ct Primary Injection Test Equipment Manufacturers –  GDSL-BX-200 Primary Current Injection Test Set – HV Hipot

    China High Quality Ct Primary Injection Test Equipment Manufacturers – GDSL-BX-200 Primary Current Injection Test Set – HV Hipot

    Features ● Digital control, high anti reference ability. ● Adapts autotransformer regulator which with low power consumption and large capacitance. ● Converter has high permeability core. ● Quick connects, lock design, have good current capability. ● PVC panel. ● Build-in quick plug with high safety. ● Current range can be changed, easy to read. ● Engineering plastics box, IP67 dustproof and waterproof. ● Portable design is suitable for on-site testing. ● Zero start function to prevent the test objects from damage caused by high current impulsing. The equipment only can be started at zero. ● Impulse choosing function: The current value can be outputted directly without zero protection function when the equipment is under the testing for circuit breaker. ● 0-50A AC current can be outp...
  • OEM Best portable dew point meter Suppliers –   GDSZ-402 Automatic Acid Value Tester – HV Hipot

    OEM Best portable dew point meter Suppliers – GDSZ-402 Automatic Acid Value Tester – HV Hipot

    General Information  Automatic Acid Value Tester is designed for testing acid value for transformer oil, turbine oil and fire resistant oil etc. PC control system can improve the work efficiency and reduce the harm in organic solvents and chemicals to human body. This instrument is easy to operate and have good capacity in anti-interference and stability.  Features ● 320*240 LCD touch screen, user-friendly interface. ● Neutralization titration principle, to complete liquid charge, titrate, stir, determine the titration end point automatically under normal temperature. LCD screen can show the test result and print. ● Color sensor can match up the test titration end point, the judgment of end condition is reliable. ● Waste liquor cup is no need. ● Peristaltic pump control the cha...
  • OEM Best furse lightning protection Supplier –  Online Monitoring System for Metal Oxide Arrester – HV Hipot

    OEM Best furse lightning protection Supplier – Online Monitoring System for Metal Oxide Arrester – HV Hipot

    General Information There are usually two ways to monitor the insulation condition of high voltage electrical equipment in substations: online monitoring and live (portable) online detection. The former one can obtain the characteristic parameters reflecting the abnormal insulation of the equipment at any time, which is convenient for automatic management. However, the investment is relatively large, the installation and construction are relatively troublesome, and regular maintenance is needed. For the latter, it has the advantages of low investment, highly targeted, easy to install, maintain and update. As long as the sampling unit is installed in the electrical equipment in advance, a regular detection can be done for electrical equipment in operation, and insulation flaw can be f...
  • China High Quality relay tester Supplier –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot

    China High Quality relay tester Supplier – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot

    Features A. Working conditions 1. Power supply: AC 220V±10%,50Hz 2. Working environment: Temperature -10℃~40℃; Humidity: ≤85% 3. Atmosphere: 86-106kPa B. Output power supply 1. AC voltage: 0-220V/3A  Adjustable 2. AC current: 0-100A/7V (200A can be customized);  0-20A/25V  Adjustable; 0-5A/5V  Adjustable 3. DC voltage: 0-220V/3A  Adjustable 4. DC current:0-20A/25V 5. Fixed voltage output: DC 24V/48V/110V/220V 6. Current/Voltage accuracy: ±1%. C. Performance Index 1. Ammeter and voltmeter: 41/2 digit. 2. Digital millisecond meter: 0-99.9999s(999.999s can be customized) Resolution: 0.1ms. D. Functions 1. Measure relay: Measure start value, return value and drop-off to pick-up ratio of current, voltage relay. 2. Time relay: Measure start value, return value and action time. 3. Intermed...
  • OEM Best Cable Testing Methods Manufacturer –  GD-7018A Optical Fiber Identifier – HV Hipot

    OEM Best Cable Testing Methods Manufacturer – GD-7018A Optical Fiber Identifier – HV Hipot

    The GD-7018 series optical fiber pipeline identifier can accurately locate and meaure depth of the underground pipelines, cables and optical cables under the condition of without digging, and accurately find the damage points of the outer coating of the underground pipelines and the location of the underground cable fault points. The instrument incorporates the most advanced technologies such as ultra-narrow band filter, Bluetooth wireless communication, GPS positioning, automatic data mapping by professional data analysis software and automatic generation of test reports. The detection and inspection of various kinds of metal pipelines, pipeline management and maintenance, municipal planning and construction, pipeline inspection in power supply and other departments is one of the neces...
  • China High Quality Cable Fault Location Factory –  GD-2134A Cable Identifier – HV Hipot

    China High Quality Cable Fault Location Factory – GD-2134A Cable Identifier – HV Hipot

    The purpose of the cable identifier is to accurately identify one of the target cables from multiple cables and avoid serious accidents caused by wrong sawing of live cables. Cable identification starts from the operation of both ends of the cable, it must be ensured that the double number on both ends of the cable is accurate. GD-2134A Cable Identifier is only suitable for on-site identification of de-energized cables. It is strictly forbidden to connect the cable identifier to the running power cable! Features ● Handheld receiver automatically identify and display the results to ensure that the results of cable identification are 100% accurate. Light weight and powerful, easy to carry. ● Suitable for on-site identification of de-energized cables. ● Both transmitter and handheld re...
  • China High Quality Portable Gas Detector Manufacturers –  GDWG-V SF6 Gas Leak Detector (IR type, Double display) – HV Hipot

    China High Quality Portable Gas Detector Manufacturers – GDWG-V SF6 Gas Leak Detector (IR type, Double display) – HV Hipot

    Product Description GDWG-V SF6 Gas Leak Detector is infrared red type leak detector (NDIR technology) with double display. It is color INCELL TFT display and real-time shows SF6 concentration. It rapidly detects SF6 breaker, GIS leakage point and yearly leakage rate qualitatively and quantitatively. It is a good device suitable for power supply department, installation and overhaul unit, power test institute. Application ● High Voltage Switch Equipment ● Rotor vane of helicopter ● Gas transmission system ● To detect fire extinguisher ● Ventilation efficiency research of Buildings ● To detect danger Advantages ● No radiation. ● No need to replace high pressure high pure argon gas regularly. ● No need to approach high pressure gas. ● No need to replace sensors regularl...
  • China High Quality ir tester Suppliers –  GDHX-9700 Phase Detector – HV Hipot

    China High Quality ir tester Suppliers – GDHX-9700 Phase Detector – HV Hipot

    General Information GDHX-9700 Phase Detector is mainly used in electric power lines, phase, and phase sequence calibration in substation, with main functions including electrical inspection, phase calibration and phase sequence measurement. It uses double shielding and brand-new digital circuits, with strong anti-interference, accorded with EMC standards, suitable for various electromagnetic interference situations. The high voltage phase signal of measured lead will be transmitted directly after treatment, the handset will receive and make phase comparison, determine the results after phase detection, real-time display phase angle difference and vector. It uses wireless transmission technology, safe and reliable, fast, and accurate, suitable for using at different voltage levels (10...