OEM Best Pulse Generator Impulus Signallar Manbaai Manufacturers – GDB-H Handheld Automatic Transformer Turns Ratio Tester – HV Hipot
General Information GDB-H is a hand-held device. It can accurately measure turns ratio, group and phase angle, which is suitable for all kinds of transformers such as Z type transformers, rectifier transformers, electric furnace transformers, phase-shifting transformers, traction transformers, scott and invert-scott transformers. Function Features ● 5.6inch TFT color LCD screen, intuitively display data and vector diagram. ● 3-phase testing at the same time. Single phase power input, with internal digital combination standard sine wave test source. It generates 3-phase test power (degree of distortion is less than 0.1%, degree of symmetry is better than 0.05%) by Hi-fi power amplifier. The test results have a better equivalence, and it won’t appear constituencies misjudgmen... -
OEM Best flashpoint obtained under closed cuo condition Manufacturers – GDKS-205 Automatic Flash Point Open Cup Tester – HV Hipot
General Information GDKS-205 automatic open cup flash point tester is the device testing open cup flash point for petroleum products. It use module design which one host can control several testing furnace, to test different samples at the same time or separately. The testing furnace port can be connected to the host disorderly. It widely used in the field of railway, air company, power, petroleum and research department. Features ● 320*240 TFT LCD touch screen. ● With high speed signal processor control, reliable and high accuracy. ● One host can control several test furnace to test several samples at one time, which will save testing time. ● Detection, ignition, alarm, cooling, printing, the whole testing process is completed automatically. ● Platinum electric wire or gas ignit... -
China High Quality dew point test Supplier – GDC-9560B Power System Insulation Oil Gas Chromatograph Analyzer – HV Hipot
General Information GDC-9560B Gas Chromatograph Analyzer is to analyze the gas content of insulation oil by gas chromatographic method. It is effective to judge if the running equipment has potential fault like over-heat, discharge or not, to ensure the safety of power grid. It is also necessary to be used for manufacturer of gas/oil equipment to inspect their equipment before leaving factory. Gas chromatography analysis technology is a technique for separation and analysis of multi-component mixtures. It mainly uses the difference of boiling point, polarity and adsorption coefficient of each component in the sample in the column, so that the components are separated in the column, and the separated components are qualitatively and quantitatively analyzed. The gas chromatograph uses... -
OEM Best Resistance Testing Equipment Factories – GDHL-100B Contact Resistance Tester (Microhm Meter) – HV Hipot
Description The performance of the conductive circuit of the circuit breaker is important to ensure the safe operation of the switch. The pros and cons of the conductive performance can be reflected by the size of the resistance of the conductive loop. Therefore, the IEC standard and the manufacturer have stipulated that the loop resistance should be measured, and there are clear specifications for the loop resistance of various types of switches. The loop resistance tester is a testing instrument meets the requirements of GB50150-2006 and DL / T 845.4-2004 regulations. It is widely applicable to the measurement of contact resistance, loop resistance, cable, wire, and weld contact resistance of various electrical switches. Application ● High,middle and low voltage circuit breakers... -
China High Quality current transformer insulation resistance test Factory – GDF-3000 DC System Earth Fault Detector – HV Hipot
General Information In DC system, there are many earth faults including indirect earth fault, non-metal earth fault, loop earth fault, positive and negative earthing fault, positive and negative balance earth fault, multi-point earth fault. GDF-3000 Earth Fault Tester for DC System locates these earth faults and displays the parameters of system voltage, earth voltage, earth resistance and earth impedance of branches accurately. Functions ● System ground voltage measurement function, the instrument can measure the system ground voltage, negative to ground voltage, system voltage, can achieve 0-300V voltage monitoring range. ● System insulation impedance measurement function, the instrument can measure the positive to ground insulation impedance and the negative to ground insulatio... -
OEM Best Capacitor For Exporters – AC Dielectric Test Equipment with manual control unit GDYD-D – HV Hipot
Application Features ● Digital (Pointe) display panel mounted controls & indicators with easy-to-read legend. ● Monitoring high voltage side voltage, low voltage side current and indicator of zero, power, working start, timing. ● Over-current protection, zero-starting protection, sound, and light alarm. ● Continuously variable output from zero to full voltage. ● Adjustable over current protection, with trip levels variable from 10 to 110%. ● With new type time relay, time range is wider (1S ~ 99H). ● Using the latest current relay, more accurate and reliable. ● Light weight, small size, easy to move. Technical Specifications ● Input voltage: AC 220V or 380V ● Output voltage of control unit: AC 0-250V or 0-430V ● Output current of control unit:0-5/10/15/50A(customized) ● Ca... -
OEM Best surface partial discharge Factory – GDPD-313M Portable Partial Discharge Detector – HV Hipot
External flexible sensor (for option) Parabolic sensor (wave condenser, for option) TEV and AE method is acknowledged and suitable technology to be used in online partial discharge detection. GDPD-313M uses ultrasonic detection technology (AE) and TEV mode, which can effectively ensure signal sensitivity in the interference on-site environment. It is suitable to detect PD flaw and locate PD signal for switch cabinet etc. Features ● Built-in ultrasonic sensor. electrical fault generates ultrasonic wave at the fault point, and ultrasonic mode transmits the ultrasonic signal through the earphone to scan the area to detect the discharge. Various characteristics of vibration, pop, and hum can be associated with different faults. ● Built-in high-precision TEV sensor, coupled with electrom... -
OEM Best Tan Delta Of Transformer Oil Suppliers – DC High Voltage Generator GDZG-300 – HV Hipot
Features ● Simple operation and complete function, easy for wild work. ● Higher voltage stability, smaller ripple coefficient. ● More reliable and stable, continuous short-circuit discharge directly to ground. ● Intelligent grounding protection and alarm function. High precision, accurate measurement, digital display of voltmeter and ammeter, with voltage resolution 0.1kV, and current 0.1uA. ● High stability of voltage regulation, smooth voltage boosting process, high adjustable precision, with coarse and fine adjustment functions. Accuracy of voltage regulation better than 0.1%, voltage and current measurement error is less than 1.0%, ripple factor better than 0.5%. ● With function of high-accuracy 75%VDC-1mA, more convenient for zinc oxide lighting arrester DC testing. ● HV booste... -
OEM Best price of lt&ht megger Manufacturer – Online Monitoring System of Circulating Current on Cable Sheath GDCO-301 – HV Hipot
General Information Cables above 35kV are mainly single-core cables with metal sheath. Since the metal sheath of the single-core cable is hinged with the magnetic field line generated by the AC current in the core wire, the two ends of the single-core cable have a high induced voltage. Therefore, appropriate grounding measures should be taken to keep the induced voltage within the safe voltage range (usually no more than 50V, but no more than 100V with safety measures). Usually, the metal sheath of short line single-core cable is grounded directly at one end and grounded through gap or protection resistor at the other end. The metal sheath of long line single – core cable is grounded by three – phase segmental cross – connection. No matter which kind of grounding me... -
OEM Best harga earth resistance & resistivity tester Exporters – GDDT-10U Digital Grounding Down Lead Earth Continuity Tester – HV Hipot
General Information GDDT-10U Earth Continuity Resistance Tester is a highly automatic and portable test equipment. It is applied to the measurement of breakover resistance value among earth connecting cables of substation electrical equipment. The adoption of high-performance single-chip control helps to achieve intelligence of testing process. It is small size, convenient to carry, easy to operate, high-accuracy, fast testing speed, good testing repeatability, clear to read. Features ● The instrument is controlled by high-speed single chip, thus it’s highly automatic and easy to operate. ● Using new power source technology, with many more current steps and wide measuring range. ● Intelligent power management technology, the instrument can work in the state of Min. power, w... -
China High Quality lightning strike radar Supplier – GD-610B Insulator Faults Detector – HV Hipot
General Information In High Voltage Distribution Network, it usually cause the faults of flashover, grounding or porcelain explosion because of insulators degradation. So it is important to detect and eliminate the faults of insulators, to ensure safe running of transmission and distribution line. GD-610B Insulator Faults Detector is used to locate insulator faults in power plants and substation transmission lines under uninterrupted power state. It can also be used in partial discharge detection of electrical equipment, corona discharge detection, high voltage switch discharge detection and so on. Applications The electric power, agricultural power, water conservancy and other departments in all regions that have power transmission lines, as well as scientific research units of i... -
OEM Best megger testing equipment Factory – GDWR-5A Earth Resistance Tester for Ground Grid – HV Hipot
Product Description GDWR-5A Earth Resistance Tester is a high-precision test instrument used in various fields such as substations for testing grounding resistance and related parameters. The instrument has the characteristics of small volume, light weight, convenient carrying, strong anti-interference performance and high accuracy. The instrument is an integrated structure, built-in variable frequency power supply module, and the output power supply is continuously variable frequency adjustable. The frequency can be changed to 45Hz or 55Hz, and the built-in high-speed processor core adopts high-end digital filtering technology, which effectively avoids the interference of the power frequency electric field to the test, and fundamentally solves the problem of accurate measurement und...