  • OEM Best Capacitor Dissipation Factor Supplier –  VLF AC Hipot Test Set 80kV – HV Hipot

    OEM Best Capacitor Dissipation Factor Supplier – VLF AC Hipot Test Set 80kV – HV Hipot

    Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test. AC test can be further divided into power frequency, variable frequency and 0.1Hz very low frequency test, among which the last one is highly recommended by IEC, due to its remarkable advantages. Following is a comparison for DC, Power Frequency, Variable Frequency, and 0.1Hz test. Aspects DC Power Frequency Variable Frequency 0.1Hz Equivalency poor good good good Insulation Damage strong slight slight slight Operation Safety relatively low relatively low relatively low high Wiring Difficulty complicated complicated most complicated simple Volume smallest largest large smal...
  • OEM Best Capacitor Spec Supplier –  Partial Discharge Test System GDYT series – HV Hipot

    OEM Best Capacitor Spec Supplier – Partial Discharge Test System GDYT series – HV Hipot

    GIT Series GIS High Voltage Test Sets integrate the high voltage boosting, high voltage measurement, high voltage transformer, high voltage coupling capacitors and all components in a sealed space. There are two modes to generate high voltage 1) Using reactor inductance and test object capacitance to realize voltage resonance test, to obtain a high voltage, high current from test object. 2) The other one is to obtain required high voltage directly from high voltage transformer. It is widely used for high voltage, big capacity GIS power equipment insulated withstand voltage test, partial discharge test and GIS transformer accuracy test, suitable for GIS substation, GIS power equipment manufacturer, basin type electrical insulator manufacturer. Features ● The High voltage o...
  • China High Quality multi relay tester Manufacturers –  GDJB-802 3 Phase Secondary Current Injection Relay Test Set – HV Hipot

    China High Quality multi relay tester Manufacturers – GDJB-802 3 Phase Secondary Current Injection Relay Test Set – HV Hipot

    General Information GDJB-802 3 Phase Secondary Current Injection Relay Protection Test Device plays a key role in operating electricity power systems reliably and safely. It can automatically judge over-current, over-voltage, overload, short circuit, high temperature, abnormal data and warning prompts for misoperation. In addition to the verification of various relays (such as current, voltage, inverse time, power direction, impedance, differential, low cycle, synchronization, frequency, DC, intermediate, time, etc.) and microcomputer protection, it can also simulate single-phase to Three-phase transient, permanent, and transitional faults are tested for the entire set. It can also complete various large-scale and complex calibration tasks with a high degree of automation, can automa...
  • China High Quality Energy meter testing Manufacturers –  GDYB-D24 Single Phase Energy Meter Test System – HV Hipot

    China High Quality Energy meter testing Manufacturers – GDYB-D24 Single Phase Energy Meter Test System – HV Hipot

    Technical Specification ● Reasonable design and beautiful appearance. The device hanging table frame and the table body frame are all made of special aluminum alloy materials, and the table top is made of fire-proof and heat-resistant fiber materials. The whole device has soft colors, coordinated proportions, and reliable structure. Exquisite craftsmanship, beautiful appearance. ● Dedicated keyboard operation and PC operation coexist, easy to use. This device is equipped with a keyboard, the keyboard comes with a liquid crystal display, and the working status of the device is clear at a glance. The operation is easy and free. The PC control software has clear levels, beautiful interface, and flexible and convenient use. ● High degree of automation. When verifying the electr...
  • OEM Best Primary Current Injection Tester Prise Supplier –  GMDL-02A HV Circuit Breaker Analog Device – HV Hipot

    OEM Best Primary Current Injection Tester Prise Supplier – GMDL-02A HV Circuit Breaker Analog Device – HV Hipot

    General Information GMDL-02A high-voltage circuit breaker simulation device is manufactured using the principles of large-scale field programmable gate arrays, power electronic devices with protection, etc. The open coil is designed according to an independent loop, which can simulate the three-phase and split-phase operation of the voltage level of 6-110KV. The action behavior of the single open coil circuit breaker is suitable for the selection of power systems, industrial and mining enterprises, scientific research institutes, professional colleges, and protection manufacturers. It is used as a substitute for actual circuit breakers in the transmission test of the entire system of relay protection and automatic devices with switches. The action is accurate, reliable, and the numbe...
  • OEM Best Capacitance Test Multimeter Manufacturers –  Surge Generator  for motor – HV Hipot

    OEM Best Capacitance Test Multimeter Manufacturers – Surge Generator for motor – HV Hipot

    GDZJ-5S Turn to Turn Surge Withstand Tester GDZJ-5S is used to test turn-to-turn insulation strength of single-phase motor, 3-phase motor, Micro motor, Special motor, electrical motor, transformer (including switching mode power supply transformer), relay and winding electrical equipment. It can detect below faults: ● Turn-to-turn Insulation breakdown ● Corona discharge ● Winding connection mistake ● Winding disconnection ● Turn-to-turn difference ● Short-circuit between interphase, winding phase, or iron core Specifications ● Peak voltage: 500-5000V continuous adjustment ● Peak error: ≤ 5% (1kV-5kV) ● Waveform rising time: 0.5μS or 0.2μS ● Power supply: 220V±10%, 50HZ ● Power consumption: ≤ 100 W ● Dimension: 480*260*390mm ● Weight: about 24kg
  • China High Quality discharge test online Suppliers –  GDPD-414H Handheld Partial Discharge Detector – HV Hipot

    China High Quality discharge test online Suppliers – GDPD-414H Handheld Partial Discharge Detector – HV Hipot

    Pictures for reference only. The GDPD-414H handheld Partial Discharge Detector adopts smart quick intelligent power test system (Soft No. 1010215, trademark registration number 14684481). It can flexibly configure various sensors according to different products to be tested. TEV, ultrasonic and HFCT are suitable for partial discharge detection of high-voltage switchgear and ring network cabinet; Ultrasonic and UHF are suitable for detecting GIS; Ultrasonic and HFCT are suitable for testing power cable. The built-in expert diagnosis system can analyze the test data and judge the discharge energy and possible parts. It is widely used in electric power and railway. Features ● Portable ABS engineering chassis. All PD detection hosts, tablets, sensors, chargers and signal cables are placed...
  • China High Quality Handheld Sf6 Gas Leak Detector Factory –  GD8000C SF6 Gas Leak Online Monitoring System – HV Hipot

    China High Quality Handheld Sf6 Gas Leak Detector Factory – GD8000C SF6 Gas Leak Online Monitoring System – HV Hipot

    Product Description GD8000C quantitatively leak online monitoring system is mainly used in the 35KV SF6 switch room and 500KV, 220KV, 110KV GIS room in the substation to monitor the SF6 gas leakage in the SF6 combined electrical equipment room environment and the oxygen content in the air in real time. When SF6 gas leaks, the density of SF6 gas is more than 5 times that of air, which accumulates in the lower space and causes local oxygen deficiency, that may cause major accidents. The system uses multiple sets of new high-sensitivity imported SF6-O2 sensors and temperature and humidity sensors. When the indoor SF6 and O2 concentrations change slightly, the sensors can respond to these changes immediately, even if the SF6 concentration is 10ppmv can be effectively monitored. The conce...
  • OEM Best Capacitor Discharge Supplier –  DC Hipot Test Set GDZG-S – HV Hipot

    OEM Best Capacitor Discharge Supplier – DC Hipot Test Set GDZG-S – HV Hipot

    Features ● Electronic control and tune, easy to operate. ● The date of voltage and current are recorded in the panel, reading without conversion. ● One minute timing and tip function. ● Perfect overvoltage and over-current protection function inside, also zinc oxide overvoltage protection outside, which ensure safety of generator. ● Both control unit and doubler packed with special shockproof aluminum alloy cabinet, easy to move. ● Portable design, suitable for on-site testing. Specifications Items(kV/mA) parameter 50/100 50/120 60/150 60/200 60/300 Output voltage(kV) 50 50 60 60 60 Output current(mA) 100 120 150 200 300 Output power(W) 5000 6000 9000 12000 18000 Voltage measurement error ≤1.0% ±1digit Current measu...
  • OEM Best harga digital megger Manufacturer –  Dielectric Loss Tester for Live Capacitive Equipment GDDJ-HVC  – HV Hipot

    OEM Best harga digital megger Manufacturer – Dielectric Loss Tester for Live Capacitive Equipment GDDJ-HVC – HV Hipot

    General Information There are usually two ways to monitor the insulation condition of high voltage electrical equipment in substations: online monitoring and live (portable) online detection. The former one can obtain the characteristic parameters reflecting the abnormal insulation of the equipment at any time, which is convenient for automatic management. However, the investment is relatively large, the installation and construction are relatively troublesome, and regular maintenance is needed. For the latter, it has the advantages of low investment, highly targeted, easy to install, maintain and update. If the sampling unit is installed in the electrical equipment in advance, a regular detection can be done for electrical equipment in operation, and insulation flaw can be found in ...
  • OEM Best Copper Cable Tester Manufacturers –  GD-7018A Optical Fiber Identifier – HV Hipot

    OEM Best Copper Cable Tester Manufacturers – GD-7018A Optical Fiber Identifier – HV Hipot

    The GD-7018 series optical fiber pipeline identifier can accurately locate and meaure depth of the underground pipelines, cables and optical cables under the condition of without digging, and accurately find the damage points of the outer coating of the underground pipelines and the location of the underground cable fault points. The instrument incorporates the most advanced technologies such as ultra-narrow band filter, Bluetooth wireless communication, GPS positioning, automatic data mapping by professional data analysis software and automatic generation of test reports. The detection and inspection of various kinds of metal pipelines, pipeline management and maintenance, municipal planning and construction, pipeline inspection in power supply and other departments is one of the neces...
  • China High Quality High Impedance Fault Suppliers –  GD-2134A Cable Identifier – HV Hipot

    China High Quality High Impedance Fault Suppliers – GD-2134A Cable Identifier – HV Hipot

    The purpose of the cable identifier is to accurately identify one of the target cables from multiple cables and avoid serious accidents caused by wrong sawing of live cables. Cable identification starts from the operation of both ends of the cable, it must be ensured that the double number on both ends of the cable is accurate. GD-2134A Cable Identifier is only suitable for on-site identification of de-energized cables. It is strictly forbidden to connect the cable identifier to the running power cable! Features ● Handheld receiver automatically identify and display the results to ensure that the results of cable identification are 100% accurate. Light weight and powerful, easy to carry. ● Suitable for on-site identification of de-energized cables. ● Both transmitter and handheld re...