info@hvhipot.com
English
CN
Home
About Us
HV HIPOT
Team
Honor & Qualification
Business Scope
Our Factory
Products
High Voltage Test Equipment
AC Hipot Test Set
DC Hipot Test Set
AC DC Combination Hipot Test Set
AC Resonant Test System
VLF AC Hipot Test Set
Partial Discharge&Corona Test System
High Voltage Divider
Turn-to-turn Surge Withstand Tester
Partial Discharge Measurement Device
Partial Discharge Analyzer
Partial Discharge Detector
Partial Discharge Online Test
Impulse Voltage and Current Test System
Impulse Voltage Test System
Impulse Current Test System
Composition Wave Test System
Transformer Test Equipment
Transformer Capacitance And Tan Delta Tester
Transformer DC Winding Resistance Tester
Transformer Load And No Load Loss Tester
Transformer Oil BDV Tester
Transformer Oil Tan Delta Tester
Transformer Test Bench
Transformer Turns Ratio Tester(TTR Tester)
Transformer Winding Deformation Tester
CT/PT Measurement And Analysis
SF6 Gas Leak Detection And Analysis
SF6 Gas Density Relay Calibrator
SF6 Gas Leak Detector
SF6 Gas Online Monitoring Device
SF6 Gas Quality Analyzer
SF6 Gas Recycling System
Switch-gear Test Equipment
Circuit Breaker Analyzer
Contact Resistance Tester
DC Power Supply
Primary Current Injection Test Set
Vacuum Switch Interrupter Vacuity Tester
Cable Fault Locating System
Cable And Pipe Locator
Cable Fault Location System
Cable Test Van
Lightning Arrester/Insulator Test Equipment
Insulator Tester
Lightning Arrester Online Test
Lightning Arrester Tester
Ultrasonic Flaw Detector
Relay Protection Tester
Digital Relay Tester
Universal Relay Tester
Insulation & Earth Resistance Tester
Earth Resistance Tester
Insulation Online Test
Insulation Resistance Tester
Phase Detector
Electric Energy Test Equipment
Energy Meter Calibrator
Power Quality Analyzer
Battery Test Equipment
AC And DC Power Supply
Battery Charge&Discharge Tester
Battery Impedance Tester
Lead Acid Battery Regenerator
Oil Test Equipment
Dissolved Gas Chromatograph Analyzer
Oil Acid Tester
Oil Filtration Machine
Oil Flash Point Tester
Oil Freezing Point Tester
Oil Tension Tester
Oil Trace Moisture Tester
Application
Operation Video
Technical Guide
High Voltage Test Equipment
Services
OEM & Customization
Other Intimate Services
News
Typical Case
Customer Visit
Company News
Contact Us
Featured
Home
Featured
China High Quality Sf6 Gas Dew Point Tester Factories – GDSF-311WPD 3-in-1 SF6 Gas Analyzer – HV Hipot
General Information GDSF-311WPD (GDSF-411WPD) is an ideal instrument when it is necessary to test water content, purity and decomposition products of SF6 gas. The core component of dew point test is DRYCAP® series sensors produced by Finland Vaisala company. The infrared principle SF6 gas purity testing sensor manufactured by European Sensor Company is used to test the purity of SF6 gas. The electrochemical sensor manufactured by Mombabo Company in Switzerland is used as the sensing element for the test of SF6 gas decomposition products. With professional hardware chips and excellent software algorithms of STMicroelectronics, we have produced a new generation of 3-in-1 gas analyzer. Application Features Specification SF6 Humidity ● Measurement method: Resistive and Capaci...
inquiry
detail
China High Quality Circuit Breaker Test Supplier – GDKC-15 Series Circuit Breaker Analyzer 2020.12 – HV Hipot
General Information High voltage circuit breaker is one of the most important control equipment in the power system. GDKC-15 Series is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate, with high accuracy. GDKC-15 Series GDKC-15A GDKC-15B GDKC-15C GDKC-15D GDKC-15E GDKC-15F GDKC-15G GDKC-15H Metal contact 12 12 12 12 12 12 12 12 Closing resistance 6 6 6 6 6 6 6 Graphite contact 3 3 3 3 6 Double-ended grounding 3 3 3 6 Dynamic resistance(Pre-insertion resistor) 1 1 3 3 3 3 6 Static resistance 1 1 3 3 3 3 6 Ground resistance 3 6 Features ● It is suitable for the mechanical test of all types of SF6 switches, GIS combination appliances, vacuum switches and oil switches. ● Strong an...
inquiry
detail
China High Quality Shock Pulse Generator Suppliers – GDB-H Handheld Automatic Transformer Turns Ratio Tester – HV Hipot
General Information GDB-H is a hand-held device. It can accurately measure turns ratio, group and phase angle, which is suitable for all kinds of transformers such as Z type transformers, rectifier transformers, electric furnace transformers, phase-shifting transformers, traction transformers, scott and invert-scott transformers. Function Features ● 5.6inch TFT color LCD screen, intuitively display data and vector diagram. ● 3-phase testing at the same time. Single phase power input, with internal digital combination standard sine wave test source. It generates 3-phase test power (degree of distortion is less than 0.1%, degree of symmetry is better than 0.05%) by Hi-fi power amplifier. The test results have a better equivalence, and it won’t appear constituencies misjudgmen...
inquiry
detail
China High Quality withstanding voltage tester, Factories – Partial Discharge Test System GDYT series – HV Hipot
GDYT is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It widely used in electrical manufacturing, power operation departments, research institutes and universities. It includes below components 1. Hipot Test Control Unit GDYD 2. PD-free Gas type transformer YDQW 3. Coupling capacitor 4. Protective resistor 5. Isolation filter LBQ 6. Partial discharge detector Features ● Advanced PD-free epoxy insulating tube, small partial discharge capacity. ● Low impedance voltage, better than national standard. ● Automatic co...
inquiry
detail
China High Quality Ct Pt Testing Factories – GDHG-201P CT/PT Analyzer – HV Hipot
Features ● Full function and can satisfy all kinds of CT (protection CT, measuring CT, TP) test requirements, such as excitation characteristic test, turn ratio, polarity, secondary winding resistance, secondary burden, ratio error, angular difference and etc. Also can used to test excitation characteristic, turn ratio, polarity, secondary winding resistance, ratio error, angular difference and etc of all kinds of PT. ● Field verification of CT does not require standard current transformers, current injector, load bank, voltage regulating controller and large current cables. Very simple test wiring and operation are used to realize the current transformer verification, which greatly reduces the work intensity and improves the work efficiency, and facilitates the field verification of...
inquiry
detail
OEM Best Pulse Generator Impulus Signallar Manbaai Factories – Impulse Voltage Test System – HV Hipot
Features ● Complete equipment and wide voltage levels in the whole set of device. ● Small electric inductance in the return circuit of the impulse voltage generator, A band-stop filtering is adopted so that a standard impulse wave is still generated even under a large capacity load, and large load capacity. ● Large in voltage utilization coefficient. ● Convenient in wave adjustment, simple in operation, excellent in synchronization performance and reliable in motion. ● An automatic control technique is adopted in the constant-current charge, which is high automation and strong anti-interference capacity. ● A digital measurement and analysis system for the impulse test date are adopted, which increase the technical level and the efficiency of the impulse voltage tests. Specifications ...
inquiry
detail
China High Quality relay test set Factories – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot
Features A. Working conditions 1. Power supply: AC 220V±10%,50Hz 2. Working environment: Temperature -10℃~40℃; Humidity: ≤85% 3. Atmosphere: 86-106kPa B. Output power supply 1. AC voltage: 0-220V/3A Adjustable 2. AC current: 0-100A/7V (200A can be customized); 0-20A/25V Adjustable; 0-5A/5V Adjustable 3. DC voltage: 0-220V/3A Adjustable 4. DC current:0-20A/25V 5. Fixed voltage output: DC 24V/48V/110V/220V 6. Current/Voltage accuracy: ±1%. C. Performance Index 1. Ammeter and voltmeter: 41/2 digit. 2. Digital millisecond meter: 0-99.9999s(999.999s can be customized) Resolution: 0.1ms. D. Functions 1. Measure relay: Measure start value, return value and drop-off to pick-up ratio of current, voltage relay. 2. Time relay: Measure start value, return value and action time. 3. Intermed...
inquiry
detail
OEM Best earthing resistance test Manufacturer – GDCR3000 Digital Earth Resistance Tester – HV Hipot
General Information GDCR3000 Digital Earth Resistance Tester is specially designed and manufactured for field measurement, adopting the latest digital and micro-processing technology, 3-pole or 2-pole method for earth resistance measurement, with a unique function of wire resistance verification, anti-interference capability and the ability to adapt to the environment, to ensure high precision, high stability and reliability for prolonged measure, which is widely used in electric power, telecommunications, meteorology, oil field, construction, lightning protection, industrial electrical equipment and other earth ground resistance measurement. Measurement range & Accuracy Measurement function Range Accuracy Resolution Earth resistance 0.01Ω~20Ω ±2%rdg ±3dgt (Auxiliary ear...
inquiry
detail
China High Quality clip on earth resistance meco make Suppliers – GDDT-10U Digital Grounding Down Lead Earth Continuity Tester – HV Hipot
General Information GDDT-10U Earth Continuity Resistance Tester is a highly automatic and portable test equipment. It is applied to the measurement of breakover resistance value among earth connecting cables of substation electrical equipment. The adoption of high-performance single-chip control helps to achieve intelligence of testing process. It is small size, convenient to carry, easy to operate, high-accuracy, fast testing speed, good testing repeatability, clear to read. Features ● The instrument is controlled by high-speed single chip, thus it’s highly automatic and easy to operate. ● Using new power source technology, with many more current steps and wide measuring range. ● Intelligent power management technology, the instrument can work in the state of Min. power, w...
inquiry
detail
China High Quality Hv Pulse Generator Manufacturers – Impulse Voltage Test System – HV Hipot
Features ● Complete equipment and wide voltage levels in the whole set of device. ● Small electric inductance in the return circuit of the impulse voltage generator, A band-stop filtering is adopted so that a standard impulse wave is still generated even under a large capacity load, and large load capacity. ● Large in voltage utilization coefficient. ● Convenient in wave adjustment, simple in operation, excellent in synchronization performance and reliable in motion. ● An automatic control technique is adopted in the constant-current charge, which is high automation and strong anti-interference capacity. ● A digital measurement and analysis system for the impulse test date are adopted, which increase the technical level and the efficiency of the impulse voltage tests. Specifications ...
inquiry
detail
OEM Best Check Circuit Breaker Suppliers – GDZK-IV Vacuum Degree Tester for Vacuum Breaker – HV Hipot
Features ● Measure vacuum degree in vacuum interrupter for every types of breakers. ● Electromagnetic measuring method, Accurate and Reliable. ● No need to dismantle the vacuum breaker in measurement. ● 128*64 pixel LCD screen, easy to operate. The test results are directly compared with the standard values to determine whether they are qualified;Save, print and check testing data. ● RS-232 port, connecting with PC to download vacuum degree-ionic current curve, to estimate lifespan. ● Light weight, Portable. Specifications ● Power Supply: AC220V ± 20%, 50Hz. ● Testing Range: 10-5 ~10-1Pa. ● Electric field Voltage: 20kV. ● Magnetic field Voltage: 1600V. ● Accuracy: 20%-25% at 10-5 ~10-4. 15%-20% at 10-4 ~10-3 10%-15% at 10-3 ~10-2 5%-10% at 10-2 ~10-1 ● Ambient Temperature: -1...
inquiry
detail
OEM Best electrical relay testing Manufacturers – GDJB-6000D Smart Substation Relay Protection Test System – HV Hipot
GDJB-6000D is equipped with high-performance power amplifier and based on the powerful PowerPC+X86 platform. It adopts modular design and have powerful functions, high precision, small size and light weight features. It can test the function and performance of merging unit, relay protection device, measurement and control device, intelligent terminals etc. Very suitable for power plants, substations, various scientific research units and equipment manufacturing enterprises. Features ● Smart Test Module Intelligent test template editing is supported. Test items can be randomly added during the test process and saved as reusable test project files to improve the test efficiency in the final stage of inspection and elimination. ● Automatic testing With on-site protection and digital pr...
inquiry
detail
<<
< Previous
180
181
182
183
184
185
186
Next >
>>
Page 183 / 278
Send your message to us:
Write your message here and send it to us
Hit enter to search or ESC to close